{"title":"局部放电模型的一些可能的新应用及其与局部放电检测灵敏度的关系","authors":"M. Danikas","doi":"10.1002/ETEP.4450060616","DOIUrl":null,"url":null,"abstract":"In this paper some possibilities of further applications of a known Streamer Partial-Discharge Model are proposed. These possibilities refer to the relation between the observed partial-discharge (PD) magnitude and the applied field to the insulation. Furthermore, the model is a useful tool to investigate the sensitivity of a PD detector and also to compare the sensitivities between various PD detectors.","PeriodicalId":50474,"journal":{"name":"European Transactions on Electrical Power","volume":"80 1","pages":"445-448"},"PeriodicalIF":0.0000,"publicationDate":"2007-09-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/ETEP.4450060616","citationCount":"4","resultStr":"{\"title\":\"Some possible new applications of a Partial-Discharge (PD) model and its relation to PD-detection sensitivity\",\"authors\":\"M. Danikas\",\"doi\":\"10.1002/ETEP.4450060616\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper some possibilities of further applications of a known Streamer Partial-Discharge Model are proposed. These possibilities refer to the relation between the observed partial-discharge (PD) magnitude and the applied field to the insulation. Furthermore, the model is a useful tool to investigate the sensitivity of a PD detector and also to compare the sensitivities between various PD detectors.\",\"PeriodicalId\":50474,\"journal\":{\"name\":\"European Transactions on Electrical Power\",\"volume\":\"80 1\",\"pages\":\"445-448\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-09-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1002/ETEP.4450060616\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Transactions on Electrical Power\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1002/ETEP.4450060616\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Transactions on Electrical Power","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/ETEP.4450060616","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Some possible new applications of a Partial-Discharge (PD) model and its relation to PD-detection sensitivity
In this paper some possibilities of further applications of a known Streamer Partial-Discharge Model are proposed. These possibilities refer to the relation between the observed partial-discharge (PD) magnitude and the applied field to the insulation. Furthermore, the model is a useful tool to investigate the sensitivity of a PD detector and also to compare the sensitivities between various PD detectors.