M. Poljak, Boris Bojanić, Tomislav Hafner, Josip Tomašević
{"title":"组合变压器的新概念","authors":"M. Poljak, Boris Bojanić, Tomislav Hafner, Josip Tomašević","doi":"10.1002/ETEP.4450060404","DOIUrl":null,"url":null,"abstract":"The basic characteristics of a new concept of combined transformers consisting of an inverse current transformer and a voltage transformer with open core, are described. The results of the research and testing of impulse and AC voltage distribution, accuracy class, influence of the current transformer on the voltage transformer and vice versa are given. Thanks to its technology and simplicity, the new concept allows the commercial manufacture of combined transformers for the highest equipment voltages up to 420 kV inclusive.","PeriodicalId":50474,"journal":{"name":"European Transactions on Electrical Power","volume":"6 1","pages":"253-258"},"PeriodicalIF":0.0000,"publicationDate":"2007-09-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/ETEP.4450060404","citationCount":"6","resultStr":"{\"title\":\"A New Concept of Combined Transformers\",\"authors\":\"M. Poljak, Boris Bojanić, Tomislav Hafner, Josip Tomašević\",\"doi\":\"10.1002/ETEP.4450060404\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The basic characteristics of a new concept of combined transformers consisting of an inverse current transformer and a voltage transformer with open core, are described. The results of the research and testing of impulse and AC voltage distribution, accuracy class, influence of the current transformer on the voltage transformer and vice versa are given. Thanks to its technology and simplicity, the new concept allows the commercial manufacture of combined transformers for the highest equipment voltages up to 420 kV inclusive.\",\"PeriodicalId\":50474,\"journal\":{\"name\":\"European Transactions on Electrical Power\",\"volume\":\"6 1\",\"pages\":\"253-258\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-09-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1002/ETEP.4450060404\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Transactions on Electrical Power\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1002/ETEP.4450060404\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Transactions on Electrical Power","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/ETEP.4450060404","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The basic characteristics of a new concept of combined transformers consisting of an inverse current transformer and a voltage transformer with open core, are described. The results of the research and testing of impulse and AC voltage distribution, accuracy class, influence of the current transformer on the voltage transformer and vice versa are given. Thanks to its technology and simplicity, the new concept allows the commercial manufacture of combined transformers for the highest equipment voltages up to 420 kV inclusive.