非超导故障限流器

M. T. Hagh, M. Abapour
{"title":"非超导故障限流器","authors":"M. T. Hagh, M. Abapour","doi":"10.1002/ETEP.247","DOIUrl":null,"url":null,"abstract":"This paper proposes the use of non-superconducting DC reactor type fault current limiter (NSFCL) instead of superconducting fault current limiters (SFCLs) which has high cost and technology. Proposed FCL consists of three similar sets, each including a diode bridge and a single non-superconducting DC reactor. The device is connected in series with distribution line and it has almost no effect on the normal system operation. It is not necessary to use a control circuit and it has a simple and cheap power circuit. Design characteristics, analytical analysis and overall transient and steady-state performance of NSFCL in normal and fault conditions are presented in this paper. The comparison between experimental and simulation results indicate good agreements. The results confirm that the power loss of NSFCL is a very small percentage of distribution line power. Also, the system current and load voltage distortions due to using NSFCL is explained and simulated. Copyright © 2008 John Wiley & Sons, Ltd.","PeriodicalId":50474,"journal":{"name":"European Transactions on Electrical Power","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2009-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/ETEP.247","citationCount":"34","resultStr":"{\"title\":\"Non-superconducting fault current limiters\",\"authors\":\"M. T. Hagh, M. Abapour\",\"doi\":\"10.1002/ETEP.247\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes the use of non-superconducting DC reactor type fault current limiter (NSFCL) instead of superconducting fault current limiters (SFCLs) which has high cost and technology. Proposed FCL consists of three similar sets, each including a diode bridge and a single non-superconducting DC reactor. The device is connected in series with distribution line and it has almost no effect on the normal system operation. It is not necessary to use a control circuit and it has a simple and cheap power circuit. Design characteristics, analytical analysis and overall transient and steady-state performance of NSFCL in normal and fault conditions are presented in this paper. The comparison between experimental and simulation results indicate good agreements. The results confirm that the power loss of NSFCL is a very small percentage of distribution line power. Also, the system current and load voltage distortions due to using NSFCL is explained and simulated. Copyright © 2008 John Wiley & Sons, Ltd.\",\"PeriodicalId\":50474,\"journal\":{\"name\":\"European Transactions on Electrical Power\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1002/ETEP.247\",\"citationCount\":\"34\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Transactions on Electrical Power\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1002/ETEP.247\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Transactions on Electrical Power","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/ETEP.247","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 34

摘要

本文提出用非超导直流电抗器型故障限流器(NSFCL)代替成本高、技术含量高的超导故障限流器(sfcl)。提议的FCL由三个类似的组件组成,每个组件包括一个二极管桥和一个非超导直流电抗器。该装置与配电线路串联,对系统的正常运行几乎没有影响。它不需要使用控制电路,并且具有简单廉价的电源电路。本文介绍了NSFCL的设计特点、解析分析以及在正常和故障工况下的总体暂态和稳态性能。仿真结果与实验结果吻合较好。结果表明,NSFCL的功率损耗占配电线路功率的比例很小。此外,还对NSFCL引起的系统电流和负载电压畸变进行了解释和仿真。版权所有©2008 John Wiley & Sons, Ltd
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Non-superconducting fault current limiters
This paper proposes the use of non-superconducting DC reactor type fault current limiter (NSFCL) instead of superconducting fault current limiters (SFCLs) which has high cost and technology. Proposed FCL consists of three similar sets, each including a diode bridge and a single non-superconducting DC reactor. The device is connected in series with distribution line and it has almost no effect on the normal system operation. It is not necessary to use a control circuit and it has a simple and cheap power circuit. Design characteristics, analytical analysis and overall transient and steady-state performance of NSFCL in normal and fault conditions are presented in this paper. The comparison between experimental and simulation results indicate good agreements. The results confirm that the power loss of NSFCL is a very small percentage of distribution line power. Also, the system current and load voltage distortions due to using NSFCL is explained and simulated. Copyright © 2008 John Wiley & Sons, Ltd.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
European Transactions on Electrical Power
European Transactions on Electrical Power 工程技术-工程:电子与电气
自引率
0.00%
发文量
0
审稿时长
5.4 months
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信