Ziad Hatab;Michael Ernst Gadringer;Ahmad Bader Alothman Alterkawi;Wolfgang Bösch
{"title":"用阶跃阻抗标准进行多线校准时参考阻抗的验证","authors":"Ziad Hatab;Michael Ernst Gadringer;Ahmad Bader Alothman Alterkawi;Wolfgang Bösch","doi":"10.1109/OJIM.2023.3315349","DOIUrl":null,"url":null,"abstract":"This article presents a new technique for evaluating the consistency of the reference impedance in multiline thru–reflect–line (TRL) calibration. During the calibration process, it is assumed that all transmission line standards have the same characteristic impedance. However, these assumptions are prone to errors due to imperfections, which can affect the validity of the reference impedance after calibration. Our proposed method involves using multiple stepped impedance lines of different lengths to extract the broadband reflection coefficient of the impedance transition. This reflection coefficient can be used to validate the reference impedance experimentally without requiring fully defined standards. We demonstrate this method using multiline TRL based on microstrip structures on a printed circuit board (PCB) with an on-wafer probing setup.","PeriodicalId":100630,"journal":{"name":"IEEE Open Journal of Instrumentation and Measurement","volume":"2 ","pages":"1-12"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/iel7/9552935/10025401/10251578.pdf","citationCount":"0","resultStr":"{\"title\":\"Validation of the Reference Impedance in Multiline Calibration With Stepped Impedance Standards\",\"authors\":\"Ziad Hatab;Michael Ernst Gadringer;Ahmad Bader Alothman Alterkawi;Wolfgang Bösch\",\"doi\":\"10.1109/OJIM.2023.3315349\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This article presents a new technique for evaluating the consistency of the reference impedance in multiline thru–reflect–line (TRL) calibration. During the calibration process, it is assumed that all transmission line standards have the same characteristic impedance. However, these assumptions are prone to errors due to imperfections, which can affect the validity of the reference impedance after calibration. Our proposed method involves using multiple stepped impedance lines of different lengths to extract the broadband reflection coefficient of the impedance transition. This reflection coefficient can be used to validate the reference impedance experimentally without requiring fully defined standards. We demonstrate this method using multiline TRL based on microstrip structures on a printed circuit board (PCB) with an on-wafer probing setup.\",\"PeriodicalId\":100630,\"journal\":{\"name\":\"IEEE Open Journal of Instrumentation and Measurement\",\"volume\":\"2 \",\"pages\":\"1-12\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-09-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ieeexplore.ieee.org/iel7/9552935/10025401/10251578.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Open Journal of Instrumentation and Measurement\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10251578/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Open Journal of Instrumentation and Measurement","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10251578/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Validation of the Reference Impedance in Multiline Calibration With Stepped Impedance Standards
This article presents a new technique for evaluating the consistency of the reference impedance in multiline thru–reflect–line (TRL) calibration. During the calibration process, it is assumed that all transmission line standards have the same characteristic impedance. However, these assumptions are prone to errors due to imperfections, which can affect the validity of the reference impedance after calibration. Our proposed method involves using multiple stepped impedance lines of different lengths to extract the broadband reflection coefficient of the impedance transition. This reflection coefficient can be used to validate the reference impedance experimentally without requiring fully defined standards. We demonstrate this method using multiline TRL based on microstrip structures on a printed circuit board (PCB) with an on-wafer probing setup.