商业海水循环水产养殖系统(RAS)中蛋白质撇除器性能的评估

IF 3.6 2区 农林科学 Q2 AGRICULTURAL ENGINEERING
Bence Dániel Kovács , Kim João de Jesus Gregersen , Florian Rüppel , Arndt von Danwitz , Lars-Flemming Pedersen
{"title":"商业海水循环水产养殖系统(RAS)中蛋白质撇除器性能的评估","authors":"Bence Dániel Kovács ,&nbsp;Kim João de Jesus Gregersen ,&nbsp;Florian Rüppel ,&nbsp;Arndt von Danwitz ,&nbsp;Lars-Flemming Pedersen","doi":"10.1016/j.aquaeng.2023.102369","DOIUrl":null,"url":null,"abstract":"<div><p>Combining protein skimming with ozone (O<sub>3</sub>) is a common method for removing microparticles in recirculating aquaculture systems (RAS). Nevertheless, there is a limited number of studies that have validated protein skimming's performance at a commercial scale. Additionally, variations in protein skimmer designs and operational variables may yield different performance outcomes. In the present study, the performance of two types of full-scale protein skimmer (S1 and S2) were compared and evaluated under two levels of hydraulic retention time (HRT) (1.8 and 2.2 min) and three levels of O<sub>3</sub> doses (0, 7, and 14 g O<sub>3</sub>/kg feed) in a commercial seawater RAS facility. Samples from the inlet and outlet of the protein skimmers were collected at each combination of operational variables. They were analysed for several relevant water quality parameters to quantify the treatment efficiency. O<sub>3</sub> dose significantly improved water quality and reduced the numbers of microparticles and bacterial activity in a single pass. Besides that, doses as high as 14 g O<sub>3</sub>/kg feed significantly increased total residual oxidant (TRO) concentration. Additionally, an increase in HRT exerted a moderate effect on removing microparticles and a strong effect on redox potential (ORP) and TRO. Finally, the type of protein skimmer only affected the ORP, causing no significant changes to other water quality metrics. The correlations between the investigated water quality parameters defined a clear pattern of the ongoing processes and particle characteristics. Overall, the results demonstrated that protein skimming combined with carefully selected O<sub>3</sub> doses can improve general water quality and control critical factors such as bacterial activity and microparticles under commercial operations.</p></div>","PeriodicalId":8120,"journal":{"name":"Aquacultural Engineering","volume":"103 ","pages":"Article 102369"},"PeriodicalIF":3.6000,"publicationDate":"2023-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluating protein skimmer performance in a commercial seawater recirculating aquaculture system (RAS)\",\"authors\":\"Bence Dániel Kovács ,&nbsp;Kim João de Jesus Gregersen ,&nbsp;Florian Rüppel ,&nbsp;Arndt von Danwitz ,&nbsp;Lars-Flemming Pedersen\",\"doi\":\"10.1016/j.aquaeng.2023.102369\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Combining protein skimming with ozone (O<sub>3</sub>) is a common method for removing microparticles in recirculating aquaculture systems (RAS). Nevertheless, there is a limited number of studies that have validated protein skimming's performance at a commercial scale. Additionally, variations in protein skimmer designs and operational variables may yield different performance outcomes. In the present study, the performance of two types of full-scale protein skimmer (S1 and S2) were compared and evaluated under two levels of hydraulic retention time (HRT) (1.8 and 2.2 min) and three levels of O<sub>3</sub> doses (0, 7, and 14 g O<sub>3</sub>/kg feed) in a commercial seawater RAS facility. Samples from the inlet and outlet of the protein skimmers were collected at each combination of operational variables. They were analysed for several relevant water quality parameters to quantify the treatment efficiency. O<sub>3</sub> dose significantly improved water quality and reduced the numbers of microparticles and bacterial activity in a single pass. Besides that, doses as high as 14 g O<sub>3</sub>/kg feed significantly increased total residual oxidant (TRO) concentration. Additionally, an increase in HRT exerted a moderate effect on removing microparticles and a strong effect on redox potential (ORP) and TRO. Finally, the type of protein skimmer only affected the ORP, causing no significant changes to other water quality metrics. The correlations between the investigated water quality parameters defined a clear pattern of the ongoing processes and particle characteristics. Overall, the results demonstrated that protein skimming combined with carefully selected O<sub>3</sub> doses can improve general water quality and control critical factors such as bacterial activity and microparticles under commercial operations.</p></div>\",\"PeriodicalId\":8120,\"journal\":{\"name\":\"Aquacultural Engineering\",\"volume\":\"103 \",\"pages\":\"Article 102369\"},\"PeriodicalIF\":3.6000,\"publicationDate\":\"2023-09-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Aquacultural Engineering\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0144860923000560\",\"RegionNum\":2,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"AGRICULTURAL ENGINEERING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Aquacultural Engineering","FirstCategoryId":"97","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0144860923000560","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"AGRICULTURAL ENGINEERING","Score":null,"Total":0}
引用次数: 0

摘要

将蛋白质撇除与臭氧(O3)相结合是循环水产养殖系统(RAS)中去除微粒的常用方法。然而,在商业规模上验证蛋白质撇除性能的研究数量有限。此外,蛋白质撇除器设计和操作变量的变化可能产生不同的性能结果。在本研究中,在商业海水RAS设施中,在两个水平的水力停留时间(HRT)(1.8和2.2分钟)和三个水平的O3剂量(0、7和14g O3/kg饲料)下,比较和评估了两种全尺寸蛋白质撇除器(S1和S2)的性能。在操作变量的每个组合处收集来自蛋白质撇除器的入口和出口的样品。分析了几个相关的水质参数,以量化处理效率。O3剂量显著改善了水质,降低了单次通过的微粒数量和细菌活性。此外,高达14g O3/kg饲料的剂量显著提高了总残留氧化剂(TRO)浓度。此外,HRT的增加对去除微粒产生中等影响,对氧化还原电位(ORP)和TRO产生强烈影响。最后,蛋白质撇除器的类型只影响ORP,对其他水质指标没有显著变化。所调查的水质参数之间的相关性定义了正在进行的过程和颗粒特征的清晰模式。总体而言,研究结果表明,在商业运营中,蛋白质撇除与精心选择的O3剂量相结合可以改善一般水质,并控制细菌活性和微粒等关键因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluating protein skimmer performance in a commercial seawater recirculating aquaculture system (RAS)

Combining protein skimming with ozone (O3) is a common method for removing microparticles in recirculating aquaculture systems (RAS). Nevertheless, there is a limited number of studies that have validated protein skimming's performance at a commercial scale. Additionally, variations in protein skimmer designs and operational variables may yield different performance outcomes. In the present study, the performance of two types of full-scale protein skimmer (S1 and S2) were compared and evaluated under two levels of hydraulic retention time (HRT) (1.8 and 2.2 min) and three levels of O3 doses (0, 7, and 14 g O3/kg feed) in a commercial seawater RAS facility. Samples from the inlet and outlet of the protein skimmers were collected at each combination of operational variables. They were analysed for several relevant water quality parameters to quantify the treatment efficiency. O3 dose significantly improved water quality and reduced the numbers of microparticles and bacterial activity in a single pass. Besides that, doses as high as 14 g O3/kg feed significantly increased total residual oxidant (TRO) concentration. Additionally, an increase in HRT exerted a moderate effect on removing microparticles and a strong effect on redox potential (ORP) and TRO. Finally, the type of protein skimmer only affected the ORP, causing no significant changes to other water quality metrics. The correlations between the investigated water quality parameters defined a clear pattern of the ongoing processes and particle characteristics. Overall, the results demonstrated that protein skimming combined with carefully selected O3 doses can improve general water quality and control critical factors such as bacterial activity and microparticles under commercial operations.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Aquacultural Engineering
Aquacultural Engineering 农林科学-农业工程
CiteScore
8.60
自引率
10.00%
发文量
63
审稿时长
>24 weeks
期刊介绍: Aquacultural Engineering is concerned with the design and development of effective aquacultural systems for marine and freshwater facilities. The journal aims to apply the knowledge gained from basic research which potentially can be translated into commercial operations. Problems of scale-up and application of research data involve many parameters, both physical and biological, making it difficult to anticipate the interaction between the unit processes and the cultured animals. Aquacultural Engineering aims to develop this bioengineering interface for aquaculture and welcomes contributions in the following areas: – Engineering and design of aquaculture facilities – Engineering-based research studies – Construction experience and techniques – In-service experience, commissioning, operation – Materials selection and their uses – Quantification of biological data and constraints
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信