交叉剪切和接触压力对全膝关节置换术中UHMWPE-on-PEEK-OPTIMA™磨损的影响

IF 3.3 2区 医学 Q2 ENGINEERING, BIOMEDICAL
Raelene M. Cowie , Adam Briscoe , Louise M. Jennings
{"title":"交叉剪切和接触压力对全膝关节置换术中UHMWPE-on-PEEK-OPTIMA™磨损的影响","authors":"Raelene M. Cowie ,&nbsp;Adam Briscoe ,&nbsp;Louise M. Jennings","doi":"10.1016/j.jmbbm.2023.106196","DOIUrl":null,"url":null,"abstract":"<div><p>PEEK-OPTIMA™ polymer is being considered as an alternative material to cobalt chrome in the femoral component of total knee arthroplasty to give a metal-free knee replacement system. Simple geometry pin-on-plate wear simulation can be used to systematically investigate and understand the wear of materials under many different conditions. The aim of this study was to investigate the wear of UHMWPE-on-PEEK-OPTIMA™ under a range of contact pressure (2.1–80 MPa) and cross-shear ratio (0–0.18) conditions.</p><p>With increasing contact pressure, there was a trend of decreasing UHMWPE wear factor with a significant difference (p&lt;0.001) in the wear factor of UHMWPE under the different contact pressure conditions of interest. Under uniaxial motion (cross-shear ratio = 0), the wear of UHMWPE was low, introducing multi-axial motion increased the wear of the UHMWPE. There was a significant difference (p&lt;0.01) in the wear factor at different cross-shear ratios however, post hoc analysis showed only the study carried out under unidirectional motion to be significantly different from the other conditions.</p><p>With varying contact pressure and cross-shear ratio, the wear of UHMWPE against PEEK-OPTIMA™ polymer showed similar trends to previous studies of UHMWPE-on-cobalt chrome.</p></div>","PeriodicalId":380,"journal":{"name":"Journal of the Mechanical Behavior of Biomedical Materials","volume":"148 ","pages":"Article 106196"},"PeriodicalIF":3.3000,"publicationDate":"2023-10-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1751616123005490/pdfft?md5=2f472a62a6efdcb91fcb290bfb271c1a&pid=1-s2.0-S1751616123005490-main.pdf","citationCount":"0","resultStr":"{\"title\":\"The influence of cross shear and contact pressure on the wear of UHMWPE-on-PEEK-OPTIMA™ for use in total knee replacement\",\"authors\":\"Raelene M. Cowie ,&nbsp;Adam Briscoe ,&nbsp;Louise M. Jennings\",\"doi\":\"10.1016/j.jmbbm.2023.106196\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>PEEK-OPTIMA™ polymer is being considered as an alternative material to cobalt chrome in the femoral component of total knee arthroplasty to give a metal-free knee replacement system. Simple geometry pin-on-plate wear simulation can be used to systematically investigate and understand the wear of materials under many different conditions. The aim of this study was to investigate the wear of UHMWPE-on-PEEK-OPTIMA™ under a range of contact pressure (2.1–80 MPa) and cross-shear ratio (0–0.18) conditions.</p><p>With increasing contact pressure, there was a trend of decreasing UHMWPE wear factor with a significant difference (p&lt;0.001) in the wear factor of UHMWPE under the different contact pressure conditions of interest. Under uniaxial motion (cross-shear ratio = 0), the wear of UHMWPE was low, introducing multi-axial motion increased the wear of the UHMWPE. There was a significant difference (p&lt;0.01) in the wear factor at different cross-shear ratios however, post hoc analysis showed only the study carried out under unidirectional motion to be significantly different from the other conditions.</p><p>With varying contact pressure and cross-shear ratio, the wear of UHMWPE against PEEK-OPTIMA™ polymer showed similar trends to previous studies of UHMWPE-on-cobalt chrome.</p></div>\",\"PeriodicalId\":380,\"journal\":{\"name\":\"Journal of the Mechanical Behavior of Biomedical Materials\",\"volume\":\"148 \",\"pages\":\"Article 106196\"},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2023-10-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S1751616123005490/pdfft?md5=2f472a62a6efdcb91fcb290bfb271c1a&pid=1-s2.0-S1751616123005490-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Mechanical Behavior of Biomedical Materials\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1751616123005490\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Mechanical Behavior of Biomedical Materials","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1751616123005490","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

偷看™ 在全膝关节置换术的股骨部件中,聚合物被认为是钴铬的替代材料,以提供无金属的膝关节置换系统。简单的几何销-板磨损模拟可以用来系统地研究和理解材料在许多不同条件下的磨损。本研究的目的是研究UHMWPE在PEEK OPTIMA上的磨损™ 在接触压力(2.1-80MPa)和交叉剪切比(0-0.18)的条件下。随着接触压力的增加,超高分子量聚乙烯的磨损因子有降低的趋势,且有显著差异(p
本文章由计算机程序翻译,如有差异,请以英文原文为准。

The influence of cross shear and contact pressure on the wear of UHMWPE-on-PEEK-OPTIMA™ for use in total knee replacement

The influence of cross shear and contact pressure on the wear of UHMWPE-on-PEEK-OPTIMA™ for use in total knee replacement

PEEK-OPTIMA™ polymer is being considered as an alternative material to cobalt chrome in the femoral component of total knee arthroplasty to give a metal-free knee replacement system. Simple geometry pin-on-plate wear simulation can be used to systematically investigate and understand the wear of materials under many different conditions. The aim of this study was to investigate the wear of UHMWPE-on-PEEK-OPTIMA™ under a range of contact pressure (2.1–80 MPa) and cross-shear ratio (0–0.18) conditions.

With increasing contact pressure, there was a trend of decreasing UHMWPE wear factor with a significant difference (p<0.001) in the wear factor of UHMWPE under the different contact pressure conditions of interest. Under uniaxial motion (cross-shear ratio = 0), the wear of UHMWPE was low, introducing multi-axial motion increased the wear of the UHMWPE. There was a significant difference (p<0.01) in the wear factor at different cross-shear ratios however, post hoc analysis showed only the study carried out under unidirectional motion to be significantly different from the other conditions.

With varying contact pressure and cross-shear ratio, the wear of UHMWPE against PEEK-OPTIMA™ polymer showed similar trends to previous studies of UHMWPE-on-cobalt chrome.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of the Mechanical Behavior of Biomedical Materials
Journal of the Mechanical Behavior of Biomedical Materials 工程技术-材料科学:生物材料
CiteScore
7.20
自引率
7.70%
发文量
505
审稿时长
46 days
期刊介绍: The Journal of the Mechanical Behavior of Biomedical Materials is concerned with the mechanical deformation, damage and failure under applied forces, of biological material (at the tissue, cellular and molecular levels) and of biomaterials, i.e. those materials which are designed to mimic or replace biological materials. The primary focus of the journal is the synthesis of materials science, biology, and medical and dental science. Reports of fundamental scientific investigations are welcome, as are articles concerned with the practical application of materials in medical devices. Both experimental and theoretical work is of interest; theoretical papers will normally include comparison of predictions with experimental data, though we recognize that this may not always be appropriate. The journal also publishes technical notes concerned with emerging experimental or theoretical techniques, letters to the editor and, by invitation, review articles and papers describing existing techniques for the benefit of an interdisciplinary readership.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信