人机交互中物理动态和准静态冲击下人体上臂软组织刚度分析

IF 2.2 3区 工程技术 Q3 ENGINEERING, MANUFACTURING
Nader Rajaei, Tatsuo Fujikawa, Yoji Yamada
{"title":"人机交互中物理动态和准静态冲击下人体上臂软组织刚度分析","authors":"Nader Rajaei,&nbsp;Tatsuo Fujikawa,&nbsp;Yoji Yamada","doi":"10.1002/hfm.20983","DOIUrl":null,"url":null,"abstract":"<p>Knowledge of the changes in the behavior of human soft tissue stiffness during physical impact in human–machine interaction (HMI) plays a vital role in the development of biofidelity testing devices such as a human dummy. These testing devices are widely applied as an effective means to validate the safety of machinery during dynamic or static contact with humans in HMI. In this study, we assess changes in soft tissue stiffness in the upper arm of individuals under both dynamic (0.7 and 0.25 m/s) and quasi-static (QS) impacts under a constrained contact condition. Three impactor shapes (cylindrical, cubic, and spherical) are used in this study. Impact experiments are conducted using impactors attached to a pendulum. The soft-tissue displacement is determined using an ultrasound device. The impact force-displacement curves illustrate the nonlinear behavior of the soft tissue stiffness under both dynamic and QS impacts. By utilizing the <i>“Linear Mixed Model”</i> statistical analysis, we found that changes in the impact velocity significantly influenced the changes in the nonlinear behavior of soft tissue stiffness while there was no significant effect of the changes in the impactor shape on the nonlinear behavior of the soft tissue stiffness. Additionally, we revealed that the changes in the soft tissue stiffness are influenced by the size of the contact area. Moreover, we demonstrated a range of changes in soft tissue stiffness for different impact velocities, which provide valuable information for developing future validation test devices in HMI, such as the design and evaluation of dummy skin.</p>","PeriodicalId":55048,"journal":{"name":"Human Factors and Ergonomics in Manufacturing & Service Industries","volume":"33 6","pages":"433-448"},"PeriodicalIF":2.2000,"publicationDate":"2023-02-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analyzing soft tissue stiffness of human upper arms during physical dynamic and quasi-static impacts in human–machine interaction\",\"authors\":\"Nader Rajaei,&nbsp;Tatsuo Fujikawa,&nbsp;Yoji Yamada\",\"doi\":\"10.1002/hfm.20983\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Knowledge of the changes in the behavior of human soft tissue stiffness during physical impact in human–machine interaction (HMI) plays a vital role in the development of biofidelity testing devices such as a human dummy. These testing devices are widely applied as an effective means to validate the safety of machinery during dynamic or static contact with humans in HMI. In this study, we assess changes in soft tissue stiffness in the upper arm of individuals under both dynamic (0.7 and 0.25 m/s) and quasi-static (QS) impacts under a constrained contact condition. Three impactor shapes (cylindrical, cubic, and spherical) are used in this study. Impact experiments are conducted using impactors attached to a pendulum. The soft-tissue displacement is determined using an ultrasound device. The impact force-displacement curves illustrate the nonlinear behavior of the soft tissue stiffness under both dynamic and QS impacts. By utilizing the <i>“Linear Mixed Model”</i> statistical analysis, we found that changes in the impact velocity significantly influenced the changes in the nonlinear behavior of soft tissue stiffness while there was no significant effect of the changes in the impactor shape on the nonlinear behavior of the soft tissue stiffness. Additionally, we revealed that the changes in the soft tissue stiffness are influenced by the size of the contact area. Moreover, we demonstrated a range of changes in soft tissue stiffness for different impact velocities, which provide valuable information for developing future validation test devices in HMI, such as the design and evaluation of dummy skin.</p>\",\"PeriodicalId\":55048,\"journal\":{\"name\":\"Human Factors and Ergonomics in Manufacturing & Service Industries\",\"volume\":\"33 6\",\"pages\":\"433-448\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2023-02-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Human Factors and Ergonomics in Manufacturing & Service Industries\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/hfm.20983\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, MANUFACTURING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Human Factors and Ergonomics in Manufacturing & Service Industries","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/hfm.20983","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MANUFACTURING","Score":null,"Total":0}
引用次数: 0

摘要

了解人机交互(HMI)中物理冲击过程中人体软组织刚度行为的变化,在人体假人等生物逼真度测试设备的开发中发挥着至关重要的作用。这些测试设备作为一种有效手段被广泛应用,以验证人机界面中与人动态或静态接触时机械的安全性。在这项研究中,我们评估了在动态(0.7和0.25 m/s)和准静态(QS)冲击。本研究中使用了三种冲击器形状(圆柱形、立方体和球形)。冲击实验是使用连接在摆锤上的冲击器进行的。使用超声设备来确定软组织位移。冲击力-位移曲线说明了在动态和QS冲击下软组织刚度的非线性行为。通过“线性混合模型”统计分析,我们发现冲击速度的变化显著影响软组织刚度非线性行为的变化,而冲击器形状的变化对软组织刚性非线性行为没有显著影响。此外,我们发现软组织硬度的变化受到接触面积大小的影响。此外,我们展示了不同冲击速度下软组织刚度的一系列变化,这为开发HMI中的未来验证测试设备(如假人皮肤的设计和评估)提供了有价值的信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Analyzing soft tissue stiffness of human upper arms during physical dynamic and quasi-static impacts in human–machine interaction

Knowledge of the changes in the behavior of human soft tissue stiffness during physical impact in human–machine interaction (HMI) plays a vital role in the development of biofidelity testing devices such as a human dummy. These testing devices are widely applied as an effective means to validate the safety of machinery during dynamic or static contact with humans in HMI. In this study, we assess changes in soft tissue stiffness in the upper arm of individuals under both dynamic (0.7 and 0.25 m/s) and quasi-static (QS) impacts under a constrained contact condition. Three impactor shapes (cylindrical, cubic, and spherical) are used in this study. Impact experiments are conducted using impactors attached to a pendulum. The soft-tissue displacement is determined using an ultrasound device. The impact force-displacement curves illustrate the nonlinear behavior of the soft tissue stiffness under both dynamic and QS impacts. By utilizing the “Linear Mixed Model” statistical analysis, we found that changes in the impact velocity significantly influenced the changes in the nonlinear behavior of soft tissue stiffness while there was no significant effect of the changes in the impactor shape on the nonlinear behavior of the soft tissue stiffness. Additionally, we revealed that the changes in the soft tissue stiffness are influenced by the size of the contact area. Moreover, we demonstrated a range of changes in soft tissue stiffness for different impact velocities, which provide valuable information for developing future validation test devices in HMI, such as the design and evaluation of dummy skin.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.20
自引率
8.30%
发文量
37
审稿时长
6.0 months
期刊介绍: The purpose of Human Factors and Ergonomics in Manufacturing & Service Industries is to facilitate discovery, integration, and application of scientific knowledge about human aspects of manufacturing, and to provide a forum for worldwide dissemination of such knowledge for its application and benefit to manufacturing industries. The journal covers a broad spectrum of ergonomics and human factors issues with a focus on the design, operation and management of contemporary manufacturing systems, both in the shop floor and office environments, in the quest for manufacturing agility, i.e. enhancement and integration of human skills with hardware performance for improved market competitiveness, management of change, product and process quality, and human-system reliability. The inter- and cross-disciplinary nature of the journal allows for a wide scope of issues relevant to manufacturing system design and engineering, human resource management, social, organizational, safety, and health issues. Examples of specific subject areas of interest include: implementation of advanced manufacturing technology, human aspects of computer-aided design and engineering, work design, compensation and appraisal, selection training and education, labor-management relations, agile manufacturing and virtual companies, human factors in total quality management, prevention of work-related musculoskeletal disorders, ergonomics of workplace, equipment and tool design, ergonomics programs, guides and standards for industry, automation safety and robot systems, human skills development and knowledge enhancing technologies, reliability, and safety and worker health issues.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信