{"title":"某城市加油站脉冲CP应用的调查:与常规CP的比较","authors":"Mohammad Afshari ,&nbsp;Abdoulmajid Eslami ,&nbsp;Mohammad Ali Golozar ,&nbsp;Ali Fatehi ,&nbsp;Hamid Reza Gorji ,&nbsp;Mahdi Ahmadi ,&nbsp;Amin Kavian ,&nbsp;Seyed Davod Tavosi","doi":"10.1016/j.jpse.2023.100109","DOIUrl":null,"url":null,"abstract":"<div><p>In this study, a pulse Cathodic Protection (CP) rectifier was designed and made. The performance of the pulse rectifier was monitored and compared with a conventional system. In this regard, different values of duty cycle (73% and 50%) and frequency (50 kHz and 60 kHz) were analyzed. Results showed that the AC voltage and current consumption dramatically dropped compared to the conventional rectifier. Also, the pulse CP protection potential was distributed more uniformly as a function of pulse parameters in the optimum combination of 50 kHz and 73% for frequency and duty cycle, respectively. This was explained by the changes in the electrochemical polarization resistance of the environment when utilizing the pulse CP.</p></div>","PeriodicalId":100824,"journal":{"name":"Journal of Pipeline Science and Engineering","volume":"3 2","pages":"Article 100109"},"PeriodicalIF":4.8000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Investigation on utilizing pulse CP in a city gas station: A comparison with conventional CP\",\"authors\":\"Mohammad Afshari ,&nbsp;Abdoulmajid Eslami ,&nbsp;Mohammad Ali Golozar ,&nbsp;Ali Fatehi ,&nbsp;Hamid Reza Gorji ,&nbsp;Mahdi Ahmadi ,&nbsp;Amin Kavian ,&nbsp;Seyed Davod Tavosi\",\"doi\":\"10.1016/j.jpse.2023.100109\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>In this study, a pulse Cathodic Protection (CP) rectifier was designed and made. The performance of the pulse rectifier was monitored and compared with a conventional system. In this regard, different values of duty cycle (73% and 50%) and frequency (50 kHz and 60 kHz) were analyzed. Results showed that the AC voltage and current consumption dramatically dropped compared to the conventional rectifier. Also, the pulse CP protection potential was distributed more uniformly as a function of pulse parameters in the optimum combination of 50 kHz and 73% for frequency and duty cycle, respectively. This was explained by the changes in the electrochemical polarization resistance of the environment when utilizing the pulse CP.</p></div>\",\"PeriodicalId\":100824,\"journal\":{\"name\":\"Journal of Pipeline Science and Engineering\",\"volume\":\"3 2\",\"pages\":\"Article 100109\"},\"PeriodicalIF\":4.8000,\"publicationDate\":\"2023-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Pipeline Science and Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S266714332300001X\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Pipeline Science and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S266714332300001X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

摘要

本研究设计并制作了一种脉冲阴极保护整流器。对脉冲整流器的性能进行了监测,并与传统系统进行了比较。在这方面,分析了占空比(73%和50%)和频率(50kHz和60kHz)的不同值。结果表明,与传统整流器相比,交流电压和电流消耗显著下降。此外,在频率和占空比分别为50kHz和73%的最佳组合中,脉冲CP保护电位作为脉冲参数的函数分布得更均匀。这可以通过利用脉冲CP时环境的电化学极化电阻的变化来解释。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Investigation on utilizing pulse CP in a city gas station: A comparison with conventional CP

In this study, a pulse Cathodic Protection (CP) rectifier was designed and made. The performance of the pulse rectifier was monitored and compared with a conventional system. In this regard, different values of duty cycle (73% and 50%) and frequency (50 kHz and 60 kHz) were analyzed. Results showed that the AC voltage and current consumption dramatically dropped compared to the conventional rectifier. Also, the pulse CP protection potential was distributed more uniformly as a function of pulse parameters in the optimum combination of 50 kHz and 73% for frequency and duty cycle, respectively. This was explained by the changes in the electrochemical polarization resistance of the environment when utilizing the pulse CP.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
7.50
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信