Júlia Saccol Freitas , Luiza Freitas Brum Souza , Fernando Zurlo Dellazzana , Tamires Motta Rensch da Silva , Luiza Ribeiro , Gabriel Kalil Rocha Pereira , Liliana Gressler May
{"title":"高级二硅酸锂:与其他单片修复陶瓷的半透明性和疲劳失效载荷的比较评估。","authors":"Júlia Saccol Freitas , Luiza Freitas Brum Souza , Fernando Zurlo Dellazzana , Tamires Motta Rensch da Silva , Luiza Ribeiro , Gabriel Kalil Rocha Pereira , Liliana Gressler May","doi":"10.1016/j.jmbbm.2023.106192","DOIUrl":null,"url":null,"abstract":"<div><p>The aim of this <em>in vitro</em><span> study was to evaluate the surface roughness<span><span>, translucency, fatigue failure load (FFL), and number of cycles for fatigue failure (CFF) of a recently released lithia-based material called advanced lithium disilicate and three other ceramics indicated for monolithic restorations. First, ALD (advanced lithium disilicate, CEREC Tessera, Dentsply Sirona), LD (lithium disilicate, IPS e. max CAD, Ivoclar), LS (lithium silicate-disilicate, Suprinity, Vita Zahnfabrik), and 4Y-PSZ (Yttria-stabilized zirconia, IPS e.max ZirCAD MT, Ivoclar) discs (n = 15, Ø = 10 mm and thickness = 1.0 mm) were fabricated from CAD/CAM blocks/discs, A2 shade. The discs were sintered/crystallized and subsequently analyzed by a rugosimeter (Mitutoyo SJ-410) to determine Ra and Rz surface roughness parameters. Next, they were evaluated to determine the translucency parameter (TP) using a bench-top spectrophotometer (SP60, EX-Rite). The discs were subsequently cemented to glass fiber epoxy resin discs, and the specimens were tested under cyclic loading (Step-test), immersed in distilled water at a frequency of 20 Hz, with an initial </span>cyclic load<span><span> of 200 N for 5,000 cycles and increments of 50 N every 10,000 cycles until failure. Fatigue failure load (FFL) and number of cycles for fatigue failure (CFF) were recorded for subsequent Kaplan Meier analysis, with post-hoc Mantel-Cox and Weibull analysis (α = 0.05). Complementary fractographic, topographic and energy dispersive spectroscopy analyses (EDS) were performed. 4Y-PSZ showed higher survival (p < 0.05), with higher FFL and CFF (1077 N; 180,333 cycles), followed by LD (980 N; 161,000 cycles), LS (937 N; 152,333 cycles) and ALD (910 N; 147,000 cycles). No differences were observed between the tested groups regarding Weibull modulus. ALD presented TP (28.14) equal to DL (28.27) and higher than LS (25.51). All lithia-based materials had higher translucency than 4Y-PSZ (TP = 8.62) (p < 0.05). ALD appears to have a similar </span>elemental composition<span><span> to LD and LSD for oxygen and silicon. ALD and LSD have a similar </span>zirconium content. Fractures originated on the cemented surface of the ceramic discs. Lithia-based ceramics showed lower surface roughness, with ALD (Ra = 0.04 μm; Rz = 0.66 μm) showing the lowest values (p < 0.05). Despite showing lower FFL when compared to LD and 4Y-PSZ, ALD has compatible translucency and mechanical fatigue performance with its indication for fabricating monolithic, anterior and posterior adhesively cemented single-unit restorations. However, further studies are needed to substantiate its clinical performance.</span></span></span></span></p></div>","PeriodicalId":380,"journal":{"name":"Journal of the Mechanical Behavior of Biomedical Materials","volume":"148 ","pages":"Article 106192"},"PeriodicalIF":3.3000,"publicationDate":"2023-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Advanced lithium disilicate: A comparative evaluation of translucency and fatigue failure load to other ceramics for monolithic restorations\",\"authors\":\"Júlia Saccol Freitas , Luiza Freitas Brum Souza , Fernando Zurlo Dellazzana , Tamires Motta Rensch da Silva , Luiza Ribeiro , Gabriel Kalil Rocha Pereira , Liliana Gressler May\",\"doi\":\"10.1016/j.jmbbm.2023.106192\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The aim of this <em>in vitro</em><span> study was to evaluate the surface roughness<span><span>, translucency, fatigue failure load (FFL), and number of cycles for fatigue failure (CFF) of a recently released lithia-based material called advanced lithium disilicate and three other ceramics indicated for monolithic restorations. First, ALD (advanced lithium disilicate, CEREC Tessera, Dentsply Sirona), LD (lithium disilicate, IPS e. max CAD, Ivoclar), LS (lithium silicate-disilicate, Suprinity, Vita Zahnfabrik), and 4Y-PSZ (Yttria-stabilized zirconia, IPS e.max ZirCAD MT, Ivoclar) discs (n = 15, Ø = 10 mm and thickness = 1.0 mm) were fabricated from CAD/CAM blocks/discs, A2 shade. The discs were sintered/crystallized and subsequently analyzed by a rugosimeter (Mitutoyo SJ-410) to determine Ra and Rz surface roughness parameters. Next, they were evaluated to determine the translucency parameter (TP) using a bench-top spectrophotometer (SP60, EX-Rite). The discs were subsequently cemented to glass fiber epoxy resin discs, and the specimens were tested under cyclic loading (Step-test), immersed in distilled water at a frequency of 20 Hz, with an initial </span>cyclic load<span><span> of 200 N for 5,000 cycles and increments of 50 N every 10,000 cycles until failure. Fatigue failure load (FFL) and number of cycles for fatigue failure (CFF) were recorded for subsequent Kaplan Meier analysis, with post-hoc Mantel-Cox and Weibull analysis (α = 0.05). Complementary fractographic, topographic and energy dispersive spectroscopy analyses (EDS) were performed. 4Y-PSZ showed higher survival (p < 0.05), with higher FFL and CFF (1077 N; 180,333 cycles), followed by LD (980 N; 161,000 cycles), LS (937 N; 152,333 cycles) and ALD (910 N; 147,000 cycles). No differences were observed between the tested groups regarding Weibull modulus. ALD presented TP (28.14) equal to DL (28.27) and higher than LS (25.51). All lithia-based materials had higher translucency than 4Y-PSZ (TP = 8.62) (p < 0.05). ALD appears to have a similar </span>elemental composition<span><span> to LD and LSD for oxygen and silicon. ALD and LSD have a similar </span>zirconium content. Fractures originated on the cemented surface of the ceramic discs. Lithia-based ceramics showed lower surface roughness, with ALD (Ra = 0.04 μm; Rz = 0.66 μm) showing the lowest values (p < 0.05). Despite showing lower FFL when compared to LD and 4Y-PSZ, ALD has compatible translucency and mechanical fatigue performance with its indication for fabricating monolithic, anterior and posterior adhesively cemented single-unit restorations. However, further studies are needed to substantiate its clinical performance.</span></span></span></span></p></div>\",\"PeriodicalId\":380,\"journal\":{\"name\":\"Journal of the Mechanical Behavior of Biomedical Materials\",\"volume\":\"148 \",\"pages\":\"Article 106192\"},\"PeriodicalIF\":3.3000,\"publicationDate\":\"2023-10-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Mechanical Behavior of Biomedical Materials\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1751616123005453\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Mechanical Behavior of Biomedical Materials","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1751616123005453","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Advanced lithium disilicate: A comparative evaluation of translucency and fatigue failure load to other ceramics for monolithic restorations
The aim of this in vitro study was to evaluate the surface roughness, translucency, fatigue failure load (FFL), and number of cycles for fatigue failure (CFF) of a recently released lithia-based material called advanced lithium disilicate and three other ceramics indicated for monolithic restorations. First, ALD (advanced lithium disilicate, CEREC Tessera, Dentsply Sirona), LD (lithium disilicate, IPS e. max CAD, Ivoclar), LS (lithium silicate-disilicate, Suprinity, Vita Zahnfabrik), and 4Y-PSZ (Yttria-stabilized zirconia, IPS e.max ZirCAD MT, Ivoclar) discs (n = 15, Ø = 10 mm and thickness = 1.0 mm) were fabricated from CAD/CAM blocks/discs, A2 shade. The discs were sintered/crystallized and subsequently analyzed by a rugosimeter (Mitutoyo SJ-410) to determine Ra and Rz surface roughness parameters. Next, they were evaluated to determine the translucency parameter (TP) using a bench-top spectrophotometer (SP60, EX-Rite). The discs were subsequently cemented to glass fiber epoxy resin discs, and the specimens were tested under cyclic loading (Step-test), immersed in distilled water at a frequency of 20 Hz, with an initial cyclic load of 200 N for 5,000 cycles and increments of 50 N every 10,000 cycles until failure. Fatigue failure load (FFL) and number of cycles for fatigue failure (CFF) were recorded for subsequent Kaplan Meier analysis, with post-hoc Mantel-Cox and Weibull analysis (α = 0.05). Complementary fractographic, topographic and energy dispersive spectroscopy analyses (EDS) were performed. 4Y-PSZ showed higher survival (p < 0.05), with higher FFL and CFF (1077 N; 180,333 cycles), followed by LD (980 N; 161,000 cycles), LS (937 N; 152,333 cycles) and ALD (910 N; 147,000 cycles). No differences were observed between the tested groups regarding Weibull modulus. ALD presented TP (28.14) equal to DL (28.27) and higher than LS (25.51). All lithia-based materials had higher translucency than 4Y-PSZ (TP = 8.62) (p < 0.05). ALD appears to have a similar elemental composition to LD and LSD for oxygen and silicon. ALD and LSD have a similar zirconium content. Fractures originated on the cemented surface of the ceramic discs. Lithia-based ceramics showed lower surface roughness, with ALD (Ra = 0.04 μm; Rz = 0.66 μm) showing the lowest values (p < 0.05). Despite showing lower FFL when compared to LD and 4Y-PSZ, ALD has compatible translucency and mechanical fatigue performance with its indication for fabricating monolithic, anterior and posterior adhesively cemented single-unit restorations. However, further studies are needed to substantiate its clinical performance.
期刊介绍:
The Journal of the Mechanical Behavior of Biomedical Materials is concerned with the mechanical deformation, damage and failure under applied forces, of biological material (at the tissue, cellular and molecular levels) and of biomaterials, i.e. those materials which are designed to mimic or replace biological materials.
The primary focus of the journal is the synthesis of materials science, biology, and medical and dental science. Reports of fundamental scientific investigations are welcome, as are articles concerned with the practical application of materials in medical devices. Both experimental and theoretical work is of interest; theoretical papers will normally include comparison of predictions with experimental data, though we recognize that this may not always be appropriate. The journal also publishes technical notes concerned with emerging experimental or theoretical techniques, letters to the editor and, by invitation, review articles and papers describing existing techniques for the benefit of an interdisciplinary readership.