Victoria Drapal, Savannah Mosier, Anna Norman, German Berbel, Jennifer L Robinson, Elizabeth A Friis
{"title":"电活性疝网片对小鼠成纤维细胞的初步体外生存能力研究。","authors":"Victoria Drapal, Savannah Mosier, Anna Norman, German Berbel, Jennifer L Robinson, Elizabeth A Friis","doi":"10.1177/08853282231209312","DOIUrl":null,"url":null,"abstract":"<p><p>Hernias occur when part of an organ, typically the intestines, protrudes through a disruption of the fascia in the abdominal wall, leading to patient pain, discomfort, and surgical intervention. Over one million hernia repair surgeries occur annually in the USA, but globally, hernia surgeries can exceed 20 million. Standard practice includes hernia repair mesh to help hold the compromised tissue together, depending on where the fascial disruption is located and the patient's condition. However, the recurrence rate for hernias after using the most common type of hernia mesh, synthetic, is currently high. Physiological-level electrical stimulation (ES) has shown beneficial effects in improving healing in soft tissue regeneration. Piezoelectric materials can produce low-level electrical signals from mechanical loading to help speed healing. Combining the novelty of piezo elements to create an electrically active hernia repair mesh for faster healing prospects is explored in this study through simulated transcutaneous mechanical loading of the piezo element with therapeutic ultrasound. A tissue phantom was developed using Gelatin #0 and Metamucil® to better simulate a clinical application of the therapeutic ultrasound loading modality. The cellular viability of varying ultrasound intensities and temporal effects was analyzed. Overall, minimal cytotoxicity was observed across all experimental groups during the ultrasound intensity and temporal viability studies.</p>","PeriodicalId":15138,"journal":{"name":"Journal of Biomaterials Applications","volume":" ","pages":"662-669"},"PeriodicalIF":2.3000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11181991/pdf/","citationCount":"0","resultStr":"{\"title\":\"A preliminary <i>In Vitro</i> viability study of an electrically active hernia mesh on mouse fibroblasts.\",\"authors\":\"Victoria Drapal, Savannah Mosier, Anna Norman, German Berbel, Jennifer L Robinson, Elizabeth A Friis\",\"doi\":\"10.1177/08853282231209312\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Hernias occur when part of an organ, typically the intestines, protrudes through a disruption of the fascia in the abdominal wall, leading to patient pain, discomfort, and surgical intervention. Over one million hernia repair surgeries occur annually in the USA, but globally, hernia surgeries can exceed 20 million. Standard practice includes hernia repair mesh to help hold the compromised tissue together, depending on where the fascial disruption is located and the patient's condition. However, the recurrence rate for hernias after using the most common type of hernia mesh, synthetic, is currently high. Physiological-level electrical stimulation (ES) has shown beneficial effects in improving healing in soft tissue regeneration. Piezoelectric materials can produce low-level electrical signals from mechanical loading to help speed healing. Combining the novelty of piezo elements to create an electrically active hernia repair mesh for faster healing prospects is explored in this study through simulated transcutaneous mechanical loading of the piezo element with therapeutic ultrasound. A tissue phantom was developed using Gelatin #0 and Metamucil® to better simulate a clinical application of the therapeutic ultrasound loading modality. The cellular viability of varying ultrasound intensities and temporal effects was analyzed. Overall, minimal cytotoxicity was observed across all experimental groups during the ultrasound intensity and temporal viability studies.</p>\",\"PeriodicalId\":15138,\"journal\":{\"name\":\"Journal of Biomaterials Applications\",\"volume\":\" \",\"pages\":\"662-669\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2023-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11181991/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Biomaterials Applications\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/08853282231209312\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/10/20 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomaterials Applications","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/08853282231209312","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/10/20 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
A preliminary In Vitro viability study of an electrically active hernia mesh on mouse fibroblasts.
Hernias occur when part of an organ, typically the intestines, protrudes through a disruption of the fascia in the abdominal wall, leading to patient pain, discomfort, and surgical intervention. Over one million hernia repair surgeries occur annually in the USA, but globally, hernia surgeries can exceed 20 million. Standard practice includes hernia repair mesh to help hold the compromised tissue together, depending on where the fascial disruption is located and the patient's condition. However, the recurrence rate for hernias after using the most common type of hernia mesh, synthetic, is currently high. Physiological-level electrical stimulation (ES) has shown beneficial effects in improving healing in soft tissue regeneration. Piezoelectric materials can produce low-level electrical signals from mechanical loading to help speed healing. Combining the novelty of piezo elements to create an electrically active hernia repair mesh for faster healing prospects is explored in this study through simulated transcutaneous mechanical loading of the piezo element with therapeutic ultrasound. A tissue phantom was developed using Gelatin #0 and Metamucil® to better simulate a clinical application of the therapeutic ultrasound loading modality. The cellular viability of varying ultrasound intensities and temporal effects was analyzed. Overall, minimal cytotoxicity was observed across all experimental groups during the ultrasound intensity and temporal viability studies.
期刊介绍:
The Journal of Biomaterials Applications is a fully peer reviewed international journal that publishes original research and review articles that emphasize the development, manufacture and clinical applications of biomaterials.
Peer-reviewed articles by biomedical specialists from around the world cover:
New developments in biomaterials, R&D, properties and performance, evaluation and applications
Applications in biomedical materials and devices - from sutures and wound dressings to biosensors and cardiovascular devices
Current findings in biological compatibility/incompatibility of biomaterials
The Journal of Biomaterials Applications publishes original articles that emphasize the development, manufacture and clinical applications of biomaterials. Biomaterials continue to be one of the most rapidly growing areas of research in plastics today and certainly one of the biggest technical challenges, since biomaterial performance is dependent on polymer compatibility with the aggressive biological environment. The Journal cuts across disciplines and focuses on medical research and topics that present the broadest view of practical applications of biomaterials in actual clinical use.
The Journal of Biomaterial Applications is devoted to new and emerging biomaterials technologies, particularly focusing on the many applications which are under development at industrial biomedical and polymer research facilities, as well as the ongoing activities in academic, medical and applied clinical uses of devices.