模拟滑液中透明质酸与CoCrMo合金表面的相互作用

IF 1.6 Q4 ENGINEERING, BIOMEDICAL
Simona Radice, Gretchen Tibbits, Alex Y. W. Lin, Haluk Beyenal, Markus A. Wimmer
{"title":"模拟滑液中透明质酸与CoCrMo合金表面的相互作用","authors":"Simona Radice,&nbsp;Gretchen Tibbits,&nbsp;Alex Y. W. Lin,&nbsp;Haluk Beyenal,&nbsp;Markus A. Wimmer","doi":"10.1049/bsb2.12027","DOIUrl":null,"url":null,"abstract":"<p>The performance of CoCrMo alloy in orthopaedic implants may be unfavourably affected by hyaluronic acid (HA) in synovial fluid. In this study, the authors aimed to understand the interactions between HA and CoCrMo using dedicated electrochemical experiments and surface analyses. A sequence of electrochemical measurements (open-circuit potential, linear polarization resistance, potentiodynamic and potentiostatic polarizations) was run on LC-CoCrMo (ASTM F1537) in Dulbecco's phosphate-buffered saline (DPBS) solution with and without HA and in DPBS mixed with newborn calf serum (NCS) and HA, partially under simultaneous recording of surface pH using custom-made microelectrodes. Samples were analysed by optical and electron microscopy. HA had no significant impact on the corrosion potential of CoCrMo alloy (<i>E</i><sub>CORR</sub> = −173 ± 8, −211 ± 16, and −254 ± 30 mV<sub>Ag/AgCl</sub>, in DPBS, DPBS + HA, and DPBS + NCS + HA, respectively). Average current density values at the transpassive domain were double in DPBS compared to DPBS + HA and DPBS + NCS + HA. At potentials above +0.6 V<sub>Ag/AgCl</sub>, surface pH values decreased from 7.5 to 6.5 in DPBS and from 7.5 to below 4 in DPBS + HA. In conclusion, the presence of HA did not compromise the corrosion resistance of CoCrMo alloy at free potential, but it enhanced acidic conditions at the near surface under anodic-applied potential in the transpassive domain.</p>","PeriodicalId":52235,"journal":{"name":"Biosurface and Biotribology","volume":"7 4","pages":"239-250"},"PeriodicalIF":1.6000,"publicationDate":"2021-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ietresearch.onlinelibrary.wiley.com/doi/epdf/10.1049/bsb2.12027","citationCount":"0","resultStr":"{\"title\":\"Interactions between hyaluronic acid and CoCrMo alloy surface in simulated synovial fluids\",\"authors\":\"Simona Radice,&nbsp;Gretchen Tibbits,&nbsp;Alex Y. W. Lin,&nbsp;Haluk Beyenal,&nbsp;Markus A. Wimmer\",\"doi\":\"10.1049/bsb2.12027\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>The performance of CoCrMo alloy in orthopaedic implants may be unfavourably affected by hyaluronic acid (HA) in synovial fluid. In this study, the authors aimed to understand the interactions between HA and CoCrMo using dedicated electrochemical experiments and surface analyses. A sequence of electrochemical measurements (open-circuit potential, linear polarization resistance, potentiodynamic and potentiostatic polarizations) was run on LC-CoCrMo (ASTM F1537) in Dulbecco's phosphate-buffered saline (DPBS) solution with and without HA and in DPBS mixed with newborn calf serum (NCS) and HA, partially under simultaneous recording of surface pH using custom-made microelectrodes. Samples were analysed by optical and electron microscopy. HA had no significant impact on the corrosion potential of CoCrMo alloy (<i>E</i><sub>CORR</sub> = −173 ± 8, −211 ± 16, and −254 ± 30 mV<sub>Ag/AgCl</sub>, in DPBS, DPBS + HA, and DPBS + NCS + HA, respectively). Average current density values at the transpassive domain were double in DPBS compared to DPBS + HA and DPBS + NCS + HA. At potentials above +0.6 V<sub>Ag/AgCl</sub>, surface pH values decreased from 7.5 to 6.5 in DPBS and from 7.5 to below 4 in DPBS + HA. In conclusion, the presence of HA did not compromise the corrosion resistance of CoCrMo alloy at free potential, but it enhanced acidic conditions at the near surface under anodic-applied potential in the transpassive domain.</p>\",\"PeriodicalId\":52235,\"journal\":{\"name\":\"Biosurface and Biotribology\",\"volume\":\"7 4\",\"pages\":\"239-250\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2021-10-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ietresearch.onlinelibrary.wiley.com/doi/epdf/10.1049/bsb2.12027\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biosurface and Biotribology\",\"FirstCategoryId\":\"1087\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1049/bsb2.12027\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosurface and Biotribology","FirstCategoryId":"1087","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/bsb2.12027","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

滑膜液中的透明质酸(HA)可能对CoCrMo合金骨科植入物的性能产生不利影响。在这项研究中,作者旨在通过专门的电化学实验和表面分析来了解HA和CoCrMo之间的相互作用。采用LC-CoCrMo (ASTM F1537)进行一系列电化学测量(开路电位、线性极化电阻、动电位和恒电位极化),在Dulbecco的磷酸盐缓冲盐水(DPBS)溶液中(含和不含透明质酸)以及DPBS与新生牛犊血清(NCS)和透明质酸混合中进行,部分使用定制的微电极同时记录表面pH值。用光学显微镜和电子显微镜对样品进行分析。在DPBS、DPBS + HA和DPBS + NCS + HA中,HA对CoCrMo合金的腐蚀电位无显著影响(ECORR分别为- 173±8、- 211±16和- 254±30 mVAg/AgCl)。与DPBS + HA和DPBS + NCS + HA相比,DPBS在透射域的平均电流密度值是DPBS的两倍。当电位高于+0.6 VAg/AgCl时,DPBS的表面pH值从7.5降至6.5,DPBS + HA的表面pH值从7.5降至4以下。综上所述,HA的存在并没有影响CoCrMo合金在自由电位下的耐蚀性,但在阳极电位作用下却增强了合金近表面的酸性条件。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Interactions between hyaluronic acid and CoCrMo alloy surface in simulated synovial fluids

Interactions between hyaluronic acid and CoCrMo alloy surface in simulated synovial fluids

The performance of CoCrMo alloy in orthopaedic implants may be unfavourably affected by hyaluronic acid (HA) in synovial fluid. In this study, the authors aimed to understand the interactions between HA and CoCrMo using dedicated electrochemical experiments and surface analyses. A sequence of electrochemical measurements (open-circuit potential, linear polarization resistance, potentiodynamic and potentiostatic polarizations) was run on LC-CoCrMo (ASTM F1537) in Dulbecco's phosphate-buffered saline (DPBS) solution with and without HA and in DPBS mixed with newborn calf serum (NCS) and HA, partially under simultaneous recording of surface pH using custom-made microelectrodes. Samples were analysed by optical and electron microscopy. HA had no significant impact on the corrosion potential of CoCrMo alloy (ECORR = −173 ± 8, −211 ± 16, and −254 ± 30 mVAg/AgCl, in DPBS, DPBS + HA, and DPBS + NCS + HA, respectively). Average current density values at the transpassive domain were double in DPBS compared to DPBS + HA and DPBS + NCS + HA. At potentials above +0.6 VAg/AgCl, surface pH values decreased from 7.5 to 6.5 in DPBS and from 7.5 to below 4 in DPBS + HA. In conclusion, the presence of HA did not compromise the corrosion resistance of CoCrMo alloy at free potential, but it enhanced acidic conditions at the near surface under anodic-applied potential in the transpassive domain.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Biosurface and Biotribology
Biosurface and Biotribology Engineering-Mechanical Engineering
CiteScore
1.70
自引率
0.00%
发文量
27
审稿时长
11 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信