{"title":"HPLC-ELSD法测定PEG-60氢化蓖麻油中硬脂酸和12-羟基十八酸的含量","authors":"Yu Duan, Xian-Zhao Liu, En-Nian Li, Zhong-Jing Guo, Xinjun Xu","doi":"10.1556/1326.2023.01116","DOIUrl":null,"url":null,"abstract":"A rapid and simple method for the determination of stearic acid and 12-hydroxystearic acid in PEG-60 hydrogenated castor oil by high performance liquid chromatography with evaporative light scattering detection was established. The oil sample was first pretreated by alkaline hydrolysis. The analysis was performed on a Zhongpu Develop XD-C18 column (250 mm × 4.6 mm, 5 µm) with gradient elution of methanol and 1% acetic acid aqueous solution at a flow rate of 1.2 mL·min−1 and a column temperature of 40 °C. The drift tube temperature of the evaporative light scattering detection system was set at 40 °C, and the pressure of carrier gas (N2) was 337 kPa. The regression equation revealed a good linear relation (r = 0.9993–0.9995) during the test ranges (119.1–1190.7 μg·mL−1 for 12-hydroxystearic acid, 10.7–107.4 μg·mL−1 for stearic acid). The detection limits of 12-hydroxystearic acid and stearic acid were 1.1 and 2.5 μg·mL−1, the limits of quantitation were 3.2 and 7.4 μg·mL−1, respectively. And the mean recoveries were 101.5 and 101.0%, the corresponding relative standard deviations (RSDs) were 2.1 and 2.8%, respectively. The RSDs corresponding to repeatability (n = 6) were both less than 1.7% in terms of precision. As to the stability, the test results remained stable after 8 h at room temperature (RSDs were both less than 2.6%). The developed method showed high sensitivity, recovery, repeatability and stability, which indicated that the method could be applied as a quality evaluation method for the determination of stearic acid and 12-hydroxyoctadecanoic acid in PEG-60 hydrogenated castor oil.","PeriodicalId":7130,"journal":{"name":"Acta Chromatographica","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2023-03-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Determination of stearic acid and 12-hydroxyoctadecanoic acid in PEG-60 hydrogenated castor oil by HPLC-ELSD after alkaline hydrolysis\",\"authors\":\"Yu Duan, Xian-Zhao Liu, En-Nian Li, Zhong-Jing Guo, Xinjun Xu\",\"doi\":\"10.1556/1326.2023.01116\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A rapid and simple method for the determination of stearic acid and 12-hydroxystearic acid in PEG-60 hydrogenated castor oil by high performance liquid chromatography with evaporative light scattering detection was established. The oil sample was first pretreated by alkaline hydrolysis. The analysis was performed on a Zhongpu Develop XD-C18 column (250 mm × 4.6 mm, 5 µm) with gradient elution of methanol and 1% acetic acid aqueous solution at a flow rate of 1.2 mL·min−1 and a column temperature of 40 °C. The drift tube temperature of the evaporative light scattering detection system was set at 40 °C, and the pressure of carrier gas (N2) was 337 kPa. The regression equation revealed a good linear relation (r = 0.9993–0.9995) during the test ranges (119.1–1190.7 μg·mL−1 for 12-hydroxystearic acid, 10.7–107.4 μg·mL−1 for stearic acid). The detection limits of 12-hydroxystearic acid and stearic acid were 1.1 and 2.5 μg·mL−1, the limits of quantitation were 3.2 and 7.4 μg·mL−1, respectively. And the mean recoveries were 101.5 and 101.0%, the corresponding relative standard deviations (RSDs) were 2.1 and 2.8%, respectively. The RSDs corresponding to repeatability (n = 6) were both less than 1.7% in terms of precision. As to the stability, the test results remained stable after 8 h at room temperature (RSDs were both less than 2.6%). The developed method showed high sensitivity, recovery, repeatability and stability, which indicated that the method could be applied as a quality evaluation method for the determination of stearic acid and 12-hydroxyoctadecanoic acid in PEG-60 hydrogenated castor oil.\",\"PeriodicalId\":7130,\"journal\":{\"name\":\"Acta Chromatographica\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2023-03-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Chromatographica\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1556/1326.2023.01116\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Chromatographica","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1556/1326.2023.01116","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
Determination of stearic acid and 12-hydroxyoctadecanoic acid in PEG-60 hydrogenated castor oil by HPLC-ELSD after alkaline hydrolysis
A rapid and simple method for the determination of stearic acid and 12-hydroxystearic acid in PEG-60 hydrogenated castor oil by high performance liquid chromatography with evaporative light scattering detection was established. The oil sample was first pretreated by alkaline hydrolysis. The analysis was performed on a Zhongpu Develop XD-C18 column (250 mm × 4.6 mm, 5 µm) with gradient elution of methanol and 1% acetic acid aqueous solution at a flow rate of 1.2 mL·min−1 and a column temperature of 40 °C. The drift tube temperature of the evaporative light scattering detection system was set at 40 °C, and the pressure of carrier gas (N2) was 337 kPa. The regression equation revealed a good linear relation (r = 0.9993–0.9995) during the test ranges (119.1–1190.7 μg·mL−1 for 12-hydroxystearic acid, 10.7–107.4 μg·mL−1 for stearic acid). The detection limits of 12-hydroxystearic acid and stearic acid were 1.1 and 2.5 μg·mL−1, the limits of quantitation were 3.2 and 7.4 μg·mL−1, respectively. And the mean recoveries were 101.5 and 101.0%, the corresponding relative standard deviations (RSDs) were 2.1 and 2.8%, respectively. The RSDs corresponding to repeatability (n = 6) were both less than 1.7% in terms of precision. As to the stability, the test results remained stable after 8 h at room temperature (RSDs were both less than 2.6%). The developed method showed high sensitivity, recovery, repeatability and stability, which indicated that the method could be applied as a quality evaluation method for the determination of stearic acid and 12-hydroxyoctadecanoic acid in PEG-60 hydrogenated castor oil.
期刊介绍:
Acta Chromatographica
Open Access
Acta Chromatographica publishes peer-reviewed scientific articles on every field of chromatography, including theory of chromatography; progress in synthesis and characterization of new stationary phases; chromatography of organic, inorganic and complex compounds; enantioseparation and chromatography of chiral compounds; applications of chromatography in biology, pharmacy, medicine, and food analysis; environmental applications of chromatography; analytical and physico-chemical aspects of sample preparation for chromatography; hyphenated and combined techniques; chemometrics and its applications in separation science.