与冠状动脉造影相关的镉-锌-碲腔室心肌灌注成像中不同心脏应激方案的诊断性能

IF 1.6 4区 医学 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
M. Ochoa-Figueroa , J. Frías-Rose , E. Good , V. Sánchez-Rodríguez , A. Davidsson , C. Pagonis
{"title":"与冠状动脉造影相关的镉-锌-碲腔室心肌灌注成像中不同心脏应激方案的诊断性能","authors":"M. Ochoa-Figueroa ,&nbsp;J. Frías-Rose ,&nbsp;E. Good ,&nbsp;V. Sánchez-Rodríguez ,&nbsp;A. Davidsson ,&nbsp;C. Pagonis","doi":"10.1016/j.remn.2022.01.001","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><p>To evaluate the diagnostic performance of three different cardiac stress protocols for myocardial perfusion imaging (MPI) using a cadmium-zinc-telluride (CZT) camera with invasive coronary angiography (ICA) correlation for the diagnosis of coronary artery disease in a high risk population.</p></div><div><h3>Methods</h3><p>Retrospective study of 263 patients (96 women and 167 males, mean age 68 years) from which 119 patients performed a bicycle stress test (BST), 113 pharmacological stress test (PST) and 31 a combination of the two (CST) between September 2014 and December 2018. The patients then underwent myocardial perfusion imaging (MPI), followed by ICA and evaluated by means of quantitative angiography software, within six months after the MPI. The mean pre-test probability score for coronary disease according to the European Society of Cardiology criteria was 36% for the whole population. The MPI was performed in a dedicated CZT cardio camera (D-SPECT Spectrum Dynamics) with a two-day protocol, according to the European Association of Nuclear Medicine guidelines.</p></div><div><h3>Results</h3><p>No significant difference was observed between the three stress protocols in terms of diagnostic accuracy (BST 85%, PST 88% and CST 84%). The overall diagnostic accuracy of MPI to identify patients with any obstructive CAD at ICA was 86%, Sensitivity 93%, Specificity 54%, PPV 90% and NPV 63%.</p></div><div><h3>Conclusion</h3><p>The CZT D-SPECT camera achieves overall satisfactory results in the diagnosis of CAD, observing no significant differences in the diagnostic performance when the stress test was performed as a BST, PST or CST.</p></div>","PeriodicalId":48986,"journal":{"name":"Revista Espanola De Medicina Nuclear E Imagen Molecular","volume":null,"pages":null},"PeriodicalIF":1.6000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Rendimiento diagnóstico de diferentes protocolos de estrés cardiaco usados en imagen de perfusión miocárdica para el diagnóstico de enfermedad coronaria usando una cámara de cadmio-zinc-telurio con correlación con angiografía coronaria\",\"authors\":\"M. Ochoa-Figueroa ,&nbsp;J. Frías-Rose ,&nbsp;E. Good ,&nbsp;V. Sánchez-Rodríguez ,&nbsp;A. Davidsson ,&nbsp;C. Pagonis\",\"doi\":\"10.1016/j.remn.2022.01.001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Purpose</h3><p>To evaluate the diagnostic performance of three different cardiac stress protocols for myocardial perfusion imaging (MPI) using a cadmium-zinc-telluride (CZT) camera with invasive coronary angiography (ICA) correlation for the diagnosis of coronary artery disease in a high risk population.</p></div><div><h3>Methods</h3><p>Retrospective study of 263 patients (96 women and 167 males, mean age 68 years) from which 119 patients performed a bicycle stress test (BST), 113 pharmacological stress test (PST) and 31 a combination of the two (CST) between September 2014 and December 2018. The patients then underwent myocardial perfusion imaging (MPI), followed by ICA and evaluated by means of quantitative angiography software, within six months after the MPI. The mean pre-test probability score for coronary disease according to the European Society of Cardiology criteria was 36% for the whole population. The MPI was performed in a dedicated CZT cardio camera (D-SPECT Spectrum Dynamics) with a two-day protocol, according to the European Association of Nuclear Medicine guidelines.</p></div><div><h3>Results</h3><p>No significant difference was observed between the three stress protocols in terms of diagnostic accuracy (BST 85%, PST 88% and CST 84%). The overall diagnostic accuracy of MPI to identify patients with any obstructive CAD at ICA was 86%, Sensitivity 93%, Specificity 54%, PPV 90% and NPV 63%.</p></div><div><h3>Conclusion</h3><p>The CZT D-SPECT camera achieves overall satisfactory results in the diagnosis of CAD, observing no significant differences in the diagnostic performance when the stress test was performed as a BST, PST or CST.</p></div>\",\"PeriodicalId\":48986,\"journal\":{\"name\":\"Revista Espanola De Medicina Nuclear E Imagen Molecular\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2023-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revista Espanola De Medicina Nuclear E Imagen Molecular\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2253654X22000075\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Espanola De Medicina Nuclear E Imagen Molecular","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2253654X22000075","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的评价三种不同心脏应激方案的镉锌碲化照相机(CZT)心肌灌注显像(MPI)与有创冠状动脉造影(ICA)相关性对高危人群冠状动脉疾病的诊断价值。方法回顾性研究2014年9月至2018年12月263例患者(女性96例,男性167例,平均年龄68岁),其中119例患者进行了自行车压力测试(BST), 113例进行了药物压力测试(PST), 31例进行了两者结合(CST)。然后,患者在MPI后6个月内进行心肌灌注成像(MPI),随后进行ICA和定量血管造影软件评估。根据欧洲心脏病学会(European Society of Cardiology)的标准,冠状动脉疾病的平均预测概率评分为36%。根据欧洲核医学协会的指导方针,MPI在专用的CZT心脏相机(D-SPECT频谱动力学)中进行,为期两天。结果三种应激方案的诊断准确率(BST为85%,PST为88%,CST为84%)差异无统计学意义。MPI在ICA鉴别梗阻性CAD患者的总体诊断准确率为86%,敏感性93%,特异性54%,PPV 90%, NPV 63%。结论CZT D-SPECT相机对CAD的诊断效果总体满意,压力测试作为BST、PST、CST的诊断效果无显著差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Rendimiento diagnóstico de diferentes protocolos de estrés cardiaco usados en imagen de perfusión miocárdica para el diagnóstico de enfermedad coronaria usando una cámara de cadmio-zinc-telurio con correlación con angiografía coronaria

Purpose

To evaluate the diagnostic performance of three different cardiac stress protocols for myocardial perfusion imaging (MPI) using a cadmium-zinc-telluride (CZT) camera with invasive coronary angiography (ICA) correlation for the diagnosis of coronary artery disease in a high risk population.

Methods

Retrospective study of 263 patients (96 women and 167 males, mean age 68 years) from which 119 patients performed a bicycle stress test (BST), 113 pharmacological stress test (PST) and 31 a combination of the two (CST) between September 2014 and December 2018. The patients then underwent myocardial perfusion imaging (MPI), followed by ICA and evaluated by means of quantitative angiography software, within six months after the MPI. The mean pre-test probability score for coronary disease according to the European Society of Cardiology criteria was 36% for the whole population. The MPI was performed in a dedicated CZT cardio camera (D-SPECT Spectrum Dynamics) with a two-day protocol, according to the European Association of Nuclear Medicine guidelines.

Results

No significant difference was observed between the three stress protocols in terms of diagnostic accuracy (BST 85%, PST 88% and CST 84%). The overall diagnostic accuracy of MPI to identify patients with any obstructive CAD at ICA was 86%, Sensitivity 93%, Specificity 54%, PPV 90% and NPV 63%.

Conclusion

The CZT D-SPECT camera achieves overall satisfactory results in the diagnosis of CAD, observing no significant differences in the diagnostic performance when the stress test was performed as a BST, PST or CST.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Revista Espanola De Medicina Nuclear E Imagen Molecular
Revista Espanola De Medicina Nuclear E Imagen Molecular RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
1.10
自引率
16.70%
发文量
85
审稿时长
24 days
期刊介绍: The Revista Española de Medicina Nuclear e Imagen Molecular (Spanish Journal of Nuclear Medicine and Molecular Imaging), was founded in 1982, and is the official journal of the Spanish Society of Nuclear Medicine and Molecular Imaging, which has more than 700 members. The Journal, which publishes 6 regular issues per year, has the promotion of research and continuing education in all fields of Nuclear Medicine as its main aim. For this, its principal sections are Originals, Clinical Notes, Images of Interest, and Special Collaboration articles.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信