Shabana Rai, Arif Ullah, Wong Lai Kuan, Rifat Mustafa
{"title":"用于雾计算的SPIHT编码医学图像增强压缩方法","authors":"Shabana Rai, Arif Ullah, Wong Lai Kuan, Rifat Mustafa","doi":"10.1142/s0219467825500251","DOIUrl":null,"url":null,"abstract":"When it comes to filtering and compressing data before sending it to a cloud server, fog computing is a rummage sale. Fog computing enables an alternate method to reduce the complexity of medical image processing and steadily improve its dependability. Medical images are produced by imaging processing modalities using X-rays, computed tomography (CT) scans, magnetic resonance imaging (MRI) scans, and ultrasound (US). These medical images are large and have a huge amount of storage. This problem is being solved by making use of compression. In this area, lots of work is done. However, before adding more techniques to Fog, getting a high compression ratio (CR) in a shorter time is required, therefore consuming less network traffic. Le Gall5/3 integer wavelet transform (IWT) and a set partitioning in hierarchical trees (SPIHT) encoder were used in this study’s implementation of an image compression technique. MRI is used in the experiments. The suggested technique uses a modified CR and less compression time (CT) to compress the medical image. The proposed approach results in an average CR of 84.8895%. A 40.92% peak signal-to-noise ratio (PSNR) PNSR value is present. Using the Huffman coding, the proposed approach reduces the CT by 36.7434 s compared to the IWT. Regarding CR, the suggested technique outperforms IWTs with Huffman coding by 12%. The current approach has a 72.36% CR. The suggested work’s shortcoming is that the high CR caused a decline in the quality of the medical images. PSNR values can be raised, and more effort can be made to compress colored medical images and 3-dimensional medical images.","PeriodicalId":44688,"journal":{"name":"International Journal of Image and Graphics","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2023-08-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An Enhanced Compression Method for Medical Images Using SPIHT Encoder for Fog Computing\",\"authors\":\"Shabana Rai, Arif Ullah, Wong Lai Kuan, Rifat Mustafa\",\"doi\":\"10.1142/s0219467825500251\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"When it comes to filtering and compressing data before sending it to a cloud server, fog computing is a rummage sale. Fog computing enables an alternate method to reduce the complexity of medical image processing and steadily improve its dependability. Medical images are produced by imaging processing modalities using X-rays, computed tomography (CT) scans, magnetic resonance imaging (MRI) scans, and ultrasound (US). These medical images are large and have a huge amount of storage. This problem is being solved by making use of compression. In this area, lots of work is done. However, before adding more techniques to Fog, getting a high compression ratio (CR) in a shorter time is required, therefore consuming less network traffic. Le Gall5/3 integer wavelet transform (IWT) and a set partitioning in hierarchical trees (SPIHT) encoder were used in this study’s implementation of an image compression technique. MRI is used in the experiments. The suggested technique uses a modified CR and less compression time (CT) to compress the medical image. The proposed approach results in an average CR of 84.8895%. A 40.92% peak signal-to-noise ratio (PSNR) PNSR value is present. Using the Huffman coding, the proposed approach reduces the CT by 36.7434 s compared to the IWT. Regarding CR, the suggested technique outperforms IWTs with Huffman coding by 12%. The current approach has a 72.36% CR. The suggested work’s shortcoming is that the high CR caused a decline in the quality of the medical images. PSNR values can be raised, and more effort can be made to compress colored medical images and 3-dimensional medical images.\",\"PeriodicalId\":44688,\"journal\":{\"name\":\"International Journal of Image and Graphics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2023-08-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Image and Graphics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1142/s0219467825500251\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"COMPUTER SCIENCE, SOFTWARE ENGINEERING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Image and Graphics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1142/s0219467825500251","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"COMPUTER SCIENCE, SOFTWARE ENGINEERING","Score":null,"Total":0}
An Enhanced Compression Method for Medical Images Using SPIHT Encoder for Fog Computing
When it comes to filtering and compressing data before sending it to a cloud server, fog computing is a rummage sale. Fog computing enables an alternate method to reduce the complexity of medical image processing and steadily improve its dependability. Medical images are produced by imaging processing modalities using X-rays, computed tomography (CT) scans, magnetic resonance imaging (MRI) scans, and ultrasound (US). These medical images are large and have a huge amount of storage. This problem is being solved by making use of compression. In this area, lots of work is done. However, before adding more techniques to Fog, getting a high compression ratio (CR) in a shorter time is required, therefore consuming less network traffic. Le Gall5/3 integer wavelet transform (IWT) and a set partitioning in hierarchical trees (SPIHT) encoder were used in this study’s implementation of an image compression technique. MRI is used in the experiments. The suggested technique uses a modified CR and less compression time (CT) to compress the medical image. The proposed approach results in an average CR of 84.8895%. A 40.92% peak signal-to-noise ratio (PSNR) PNSR value is present. Using the Huffman coding, the proposed approach reduces the CT by 36.7434 s compared to the IWT. Regarding CR, the suggested technique outperforms IWTs with Huffman coding by 12%. The current approach has a 72.36% CR. The suggested work’s shortcoming is that the high CR caused a decline in the quality of the medical images. PSNR values can be raised, and more effort can be made to compress colored medical images and 3-dimensional medical images.