Jin Yang Zhang, Xiao Zhang, J. Chen, Xianshuai Chen
{"title":"不同牙龈高度倾斜基台单种植体支撑修复体生物力学性能的数值与实验评价","authors":"Jin Yang Zhang, Xiao Zhang, J. Chen, Xianshuai Chen","doi":"10.4028/p-p4ibv3","DOIUrl":null,"url":null,"abstract":"The effect of angle abutment on the stress distribution of bone tissue around implant is not clear. Using abutments with different gingival height (GH) may cause changes in the stress distribution of the implant and implant-bone interface. This study aims to investigate whether angled abutments with varied GH have a significant effect on stress distribution of surrounding bone and the biomechanical behavior of the implant system. Three implant-supported restoration models were designed by changing the angled abutment GH (1 mm, 3 mm and 5 mm). Force of 200N was applied on the crown surface at 45° to the long axis of the implants. The biomechanical performance of the restorations (including implants and angled abutments) and stress distribution pattern were evaluated by finite element analysis (FEA). Results showed that angled abutments with larger GH resulted in increased stresses on the implant and implant-bone interface.","PeriodicalId":15161,"journal":{"name":"Journal of Biomimetics, Biomaterials and Biomedical Engineering","volume":"58 1","pages":"111 - 119"},"PeriodicalIF":0.5000,"publicationDate":"2022-08-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Numerical and Experimental Evaluation of Biomechanical Behavior of Single Implant-Supported Restorations Based on Angled Abutments with Different Gingival Heights\",\"authors\":\"Jin Yang Zhang, Xiao Zhang, J. Chen, Xianshuai Chen\",\"doi\":\"10.4028/p-p4ibv3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The effect of angle abutment on the stress distribution of bone tissue around implant is not clear. Using abutments with different gingival height (GH) may cause changes in the stress distribution of the implant and implant-bone interface. This study aims to investigate whether angled abutments with varied GH have a significant effect on stress distribution of surrounding bone and the biomechanical behavior of the implant system. Three implant-supported restoration models were designed by changing the angled abutment GH (1 mm, 3 mm and 5 mm). Force of 200N was applied on the crown surface at 45° to the long axis of the implants. The biomechanical performance of the restorations (including implants and angled abutments) and stress distribution pattern were evaluated by finite element analysis (FEA). Results showed that angled abutments with larger GH resulted in increased stresses on the implant and implant-bone interface.\",\"PeriodicalId\":15161,\"journal\":{\"name\":\"Journal of Biomimetics, Biomaterials and Biomedical Engineering\",\"volume\":\"58 1\",\"pages\":\"111 - 119\"},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2022-08-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Biomimetics, Biomaterials and Biomedical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4028/p-p4ibv3\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomimetics, Biomaterials and Biomedical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4028/p-p4ibv3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Numerical and Experimental Evaluation of Biomechanical Behavior of Single Implant-Supported Restorations Based on Angled Abutments with Different Gingival Heights
The effect of angle abutment on the stress distribution of bone tissue around implant is not clear. Using abutments with different gingival height (GH) may cause changes in the stress distribution of the implant and implant-bone interface. This study aims to investigate whether angled abutments with varied GH have a significant effect on stress distribution of surrounding bone and the biomechanical behavior of the implant system. Three implant-supported restoration models were designed by changing the angled abutment GH (1 mm, 3 mm and 5 mm). Force of 200N was applied on the crown surface at 45° to the long axis of the implants. The biomechanical performance of the restorations (including implants and angled abutments) and stress distribution pattern were evaluated by finite element analysis (FEA). Results showed that angled abutments with larger GH resulted in increased stresses on the implant and implant-bone interface.