{"title":"粘土基陶瓷热力学分析装置","authors":"T. Húlan, I. Štubňa, Omar Al-Shantir, A. Trník","doi":"10.2478/msr-2023-0017","DOIUrl":null,"url":null,"abstract":"Abstract A dynamic thermomechanical analysis (D-TMA) apparatus is described for measuring the resonant frequency of the flexural vibration and the internal damping of the sample using the impulse excitation technique (IET). Since the measurement is conducted at temperatures up to 1250 °C, an electromagnetic impulser is used for excitation. The free vibrations are registered by an electret microphone, stored and then converted into a frequency spectrum using the fast Fourier transform, from which the resonant frequency can be found. The furnace is built from refractory porous alumina bricks and alumina fiber pads. The heating elements are four SiC rods connected to a temperature controller. The temperature is measured with a Pt-PtRh10 thermocouple in close proximity to the sample.","PeriodicalId":49848,"journal":{"name":"Measurement Science Review","volume":"23 1","pages":"130 - 135"},"PeriodicalIF":1.0000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Apparatus for Thermomechanical Analysis of Clay-based Ceramics\",\"authors\":\"T. Húlan, I. Štubňa, Omar Al-Shantir, A. Trník\",\"doi\":\"10.2478/msr-2023-0017\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract A dynamic thermomechanical analysis (D-TMA) apparatus is described for measuring the resonant frequency of the flexural vibration and the internal damping of the sample using the impulse excitation technique (IET). Since the measurement is conducted at temperatures up to 1250 °C, an electromagnetic impulser is used for excitation. The free vibrations are registered by an electret microphone, stored and then converted into a frequency spectrum using the fast Fourier transform, from which the resonant frequency can be found. The furnace is built from refractory porous alumina bricks and alumina fiber pads. The heating elements are four SiC rods connected to a temperature controller. The temperature is measured with a Pt-PtRh10 thermocouple in close proximity to the sample.\",\"PeriodicalId\":49848,\"journal\":{\"name\":\"Measurement Science Review\",\"volume\":\"23 1\",\"pages\":\"130 - 135\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2023-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Measurement Science Review\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.2478/msr-2023-0017\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Measurement Science Review","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.2478/msr-2023-0017","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
The Apparatus for Thermomechanical Analysis of Clay-based Ceramics
Abstract A dynamic thermomechanical analysis (D-TMA) apparatus is described for measuring the resonant frequency of the flexural vibration and the internal damping of the sample using the impulse excitation technique (IET). Since the measurement is conducted at temperatures up to 1250 °C, an electromagnetic impulser is used for excitation. The free vibrations are registered by an electret microphone, stored and then converted into a frequency spectrum using the fast Fourier transform, from which the resonant frequency can be found. The furnace is built from refractory porous alumina bricks and alumina fiber pads. The heating elements are four SiC rods connected to a temperature controller. The temperature is measured with a Pt-PtRh10 thermocouple in close proximity to the sample.
期刊介绍:
- theory of measurement - mathematical processing of measured data - measurement uncertainty minimisation - statistical methods in data evaluation and modelling - measurement as an interdisciplinary activity - measurement science in education - medical imaging methods, image processing - biosignal measurement, processing and analysis - model based biomeasurements - neural networks in biomeasurement - telemeasurement in biomedicine - measurement in nanomedicine - measurement of basic physical quantities - magnetic and electric fields measurements - measurement of geometrical and mechanical quantities - optical measuring methods - electromagnetic compatibility - measurement in material science