Ken Inoue, N. Yoshida, Reo Kobayashi, Y. Tomita, Hikaru Hashimoto, Satoshi Sugino, R. Hirose, O. Dohi, H. Yasuda, Ritsu Yasuda, T. Murakami, Yutaka Inada, Yoshito Itoh
{"title":"与激光内镜系统相比,紧凑发光二极管内镜系统蓝光成像对结直肠病变肿瘤特征的有效性:一项试点研究","authors":"Ken Inoue, N. Yoshida, Reo Kobayashi, Y. Tomita, Hikaru Hashimoto, Satoshi Sugino, R. Hirose, O. Dohi, H. Yasuda, Ritsu Yasuda, T. Murakami, Yutaka Inada, Yoshito Itoh","doi":"10.1155/2022/9998280","DOIUrl":null,"url":null,"abstract":"Background: A compact and cost-effective light source-processor combined 3-color light-emitting diode (LED) endoscopic system (ELUXEO-Lite: EP-6000, Fujifilm Co., Tokyo) with a magnified colonoscope (EC-6600ZP, Fujifilm Co.) has been released. Aims: In this study, we analyzed the efficacy of this system for colorectal tumor characterization with magnified blue light imaging (BLI-LED) and image's subjective and objective evaluations, compared to a magnified blue laser imaging (BLI-LASER) using a standard LASER endoscopic system. Methods: We retrospectively reviewed 37 lesions observed with both BLI-LED and BLI-LASER systems from 2019 using the Japanese narrow band imaging classification. Two representative magnified images, one BLI-LED and one BLI-LASER, of the same area of a lesion were evaluated for diagnostic accuracy and visualization quality by three experts and three non-experts. Their color difference values (CDVs) and brightness values (BVs) were also calculated as objective indicators. Results: Among 37 lesions, mean tumor size was 18.9 ± 13.1 mm, and 21 lesions were nonpolypoid. Histopathology revealed 14 sessile serrated lesions, 7 adenomas, 12 high-grade dysplasias and T1a cancers, and 4 T1b cancers. The diagnostic accuracy rates of BLI-LED/BLI-LASER of experts and non-experts were 90.1% and 87.4% (p = 0.52) and 89.2% and 89.2% (p = 0.99). The percentages of instances where BLI-LED images were better, the two imaging types were equivalent, or BLI-LASER images were better were 16%/83%/1% for experts and 19%/58%/23% for non-experts (p < 0.001). CDVs and BVs between BLI-LED and BLI-LASER were not significantly different (CDVs: p = 0.653, BVs: p = 0.518). Conclusions: BLI-LED using the compact system was noninferior to BLI-LASER for colorectal tumor characterization and image quality.","PeriodicalId":12597,"journal":{"name":"Gastroenterology Research and Practice","volume":" ","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2022-04-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Efficacy of Tumor Characterization for Colorectal Lesions with Blue Light Imaging of a Compact Light-Emitting Diode Endoscopic System Compared to a Laser Endoscopic System: A Pilot Study\",\"authors\":\"Ken Inoue, N. Yoshida, Reo Kobayashi, Y. Tomita, Hikaru Hashimoto, Satoshi Sugino, R. Hirose, O. Dohi, H. Yasuda, Ritsu Yasuda, T. Murakami, Yutaka Inada, Yoshito Itoh\",\"doi\":\"10.1155/2022/9998280\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: A compact and cost-effective light source-processor combined 3-color light-emitting diode (LED) endoscopic system (ELUXEO-Lite: EP-6000, Fujifilm Co., Tokyo) with a magnified colonoscope (EC-6600ZP, Fujifilm Co.) has been released. Aims: In this study, we analyzed the efficacy of this system for colorectal tumor characterization with magnified blue light imaging (BLI-LED) and image's subjective and objective evaluations, compared to a magnified blue laser imaging (BLI-LASER) using a standard LASER endoscopic system. Methods: We retrospectively reviewed 37 lesions observed with both BLI-LED and BLI-LASER systems from 2019 using the Japanese narrow band imaging classification. Two representative magnified images, one BLI-LED and one BLI-LASER, of the same area of a lesion were evaluated for diagnostic accuracy and visualization quality by three experts and three non-experts. Their color difference values (CDVs) and brightness values (BVs) were also calculated as objective indicators. Results: Among 37 lesions, mean tumor size was 18.9 ± 13.1 mm, and 21 lesions were nonpolypoid. Histopathology revealed 14 sessile serrated lesions, 7 adenomas, 12 high-grade dysplasias and T1a cancers, and 4 T1b cancers. The diagnostic accuracy rates of BLI-LED/BLI-LASER of experts and non-experts were 90.1% and 87.4% (p = 0.52) and 89.2% and 89.2% (p = 0.99). The percentages of instances where BLI-LED images were better, the two imaging types were equivalent, or BLI-LASER images were better were 16%/83%/1% for experts and 19%/58%/23% for non-experts (p < 0.001). CDVs and BVs between BLI-LED and BLI-LASER were not significantly different (CDVs: p = 0.653, BVs: p = 0.518). Conclusions: BLI-LED using the compact system was noninferior to BLI-LASER for colorectal tumor characterization and image quality.\",\"PeriodicalId\":12597,\"journal\":{\"name\":\"Gastroenterology Research and Practice\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2022-04-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Gastroenterology Research and Practice\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1155/2022/9998280\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"GASTROENTEROLOGY & HEPATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Gastroenterology Research and Practice","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1155/2022/9998280","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0
摘要
背景:一款紧凑且具有成本效益的光源处理器组合三色发光二极管(LED)内窥镜系统(ELUXEO-Lite: EP-6000,富士胶片公司,东京)与放大结肠镜(EC-6600ZP,富士胶片公司)已经发布。目的:在本研究中,我们分析了该系统在使用放大蓝光成像(BLI-LED)进行结直肠肿瘤表征的有效性以及图像的主客观评价,并与使用标准激光内镜系统的放大蓝光成像(BLI-LASER)进行比较。方法:回顾性分析2019年以来BLI-LED和BLI-LASER系统观察到的37个病变,采用日本窄带成像分类。由三名专家和三名非专家对病变同一区域的两幅代表性放大图像(一幅BLI-LED和一幅BLI-LASER)的诊断准确性和可视化质量进行评估。并计算其色差值(cdv)和亮度值(bv)作为客观指标。结果:37例病变中,平均肿瘤大小为18.9±13.1 mm,非息肉样病变21例。组织病理学显示14例无梗锯齿状病变,7例腺瘤,12例高度发育不良和T1a癌,4例T1b癌。专家和非专家BLI-LED/BLI-LASER的诊断准确率分别为90.1%和87.4% (p = 0.52)和89.2%和89.2% (p = 0.99)。BLI-LED图像更好、两种成像类型等效或BLI-LASER图像更好的实例百分比在专家中为16%/83%/1%,在非专家中为19%/58%/23% (p < 0.001)。BLI-LED与BLI-LASER的cdv和bv差异无统计学意义(cdv: p = 0.653, bv: p = 0.518)。结论:使用紧凑系统的BLI-LED在结直肠肿瘤特征和图像质量方面优于BLI-LASER。
The Efficacy of Tumor Characterization for Colorectal Lesions with Blue Light Imaging of a Compact Light-Emitting Diode Endoscopic System Compared to a Laser Endoscopic System: A Pilot Study
Background: A compact and cost-effective light source-processor combined 3-color light-emitting diode (LED) endoscopic system (ELUXEO-Lite: EP-6000, Fujifilm Co., Tokyo) with a magnified colonoscope (EC-6600ZP, Fujifilm Co.) has been released. Aims: In this study, we analyzed the efficacy of this system for colorectal tumor characterization with magnified blue light imaging (BLI-LED) and image's subjective and objective evaluations, compared to a magnified blue laser imaging (BLI-LASER) using a standard LASER endoscopic system. Methods: We retrospectively reviewed 37 lesions observed with both BLI-LED and BLI-LASER systems from 2019 using the Japanese narrow band imaging classification. Two representative magnified images, one BLI-LED and one BLI-LASER, of the same area of a lesion were evaluated for diagnostic accuracy and visualization quality by three experts and three non-experts. Their color difference values (CDVs) and brightness values (BVs) were also calculated as objective indicators. Results: Among 37 lesions, mean tumor size was 18.9 ± 13.1 mm, and 21 lesions were nonpolypoid. Histopathology revealed 14 sessile serrated lesions, 7 adenomas, 12 high-grade dysplasias and T1a cancers, and 4 T1b cancers. The diagnostic accuracy rates of BLI-LED/BLI-LASER of experts and non-experts were 90.1% and 87.4% (p = 0.52) and 89.2% and 89.2% (p = 0.99). The percentages of instances where BLI-LED images were better, the two imaging types were equivalent, or BLI-LASER images were better were 16%/83%/1% for experts and 19%/58%/23% for non-experts (p < 0.001). CDVs and BVs between BLI-LED and BLI-LASER were not significantly different (CDVs: p = 0.653, BVs: p = 0.518). Conclusions: BLI-LED using the compact system was noninferior to BLI-LASER for colorectal tumor characterization and image quality.
期刊介绍:
Gastroenterology Research and Practice is a peer-reviewed, Open Access journal which publishes original research articles, review articles and clinical studies based on all areas of gastroenterology, hepatology, pancreas and biliary, and related cancers. The journal welcomes submissions on the physiology, pathophysiology, etiology, diagnosis and therapy of gastrointestinal diseases. The aim of the journal is to provide cutting edge research related to the field of gastroenterology, as well as digestive diseases and disorders.
Topics of interest include:
Management of pancreatic diseases
Third space endoscopy
Endoscopic resection
Therapeutic endoscopy
Therapeutic endosonography.