STOP-Bang作为门诊患者阻塞性睡眠呼吸暂停低通气综合征的预测因子

Pub Date : 2021-11-15 DOI:10.21676/2389783x.4371
J. Pedrozo-Pupo, J. A. Egurrola-Pedraza, A. Campo‐Arias
{"title":"STOP-Bang作为门诊患者阻塞性睡眠呼吸暂停低通气综合征的预测因子","authors":"J. Pedrozo-Pupo, J. A. Egurrola-Pedraza, A. Campo‐Arias","doi":"10.21676/2389783x.4371","DOIUrl":null,"url":null,"abstract":"The STOP-Bang has been promoted as a valuable tool for identifying obstructive sleep apnea-hypopnea syndrome (OSAHS) in medical and surgical patients. However, its performance in Colombian samples is unknown. The objective of this study was to determine the clinimetric performance of the STOP-Bang index versus the study of polysomnography in patients from Santa Marta, Colombia. An accuracy study of diagnostic tests with a test-based approach was designed. Seven hundred sixty-two adults referred for polysomnography to evaluate OSAHS were included in the research. They were aged between 18 and 94 years old (mean=47.2, SD=13.4), 63.3% were men, and 46.5% were classified as obese. The STOP-Bang performance was compared against the best reference criterion, the hypopnea/apnea index determined by polysomnography. The diagnosis of OSAHS was confirmed in 461 (60.5%) and corroborated in 301 (39.5%). The area under the curve was 0.70 (95%CI 0.66-0.74), and the best cut-off point was 4, with a sensitivity of 79.2%, a specificity of 53.5%, the positive predictive value of 72.2%, the negative predictive value of 62.6%, positive likelihood ratio was 1.70, negative likelihood ratio was 0.39; OR=4.08 (CI95% 2.99-5.56) and Cohen's kappa of 0.33. As conclusions, performance indicators show that STOP-Bang...","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"STOP-Bang as a predictor of obstructive sleep apnea-hypopnea syndrome in outpatients\",\"authors\":\"J. Pedrozo-Pupo, J. A. Egurrola-Pedraza, A. Campo‐Arias\",\"doi\":\"10.21676/2389783x.4371\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The STOP-Bang has been promoted as a valuable tool for identifying obstructive sleep apnea-hypopnea syndrome (OSAHS) in medical and surgical patients. However, its performance in Colombian samples is unknown. The objective of this study was to determine the clinimetric performance of the STOP-Bang index versus the study of polysomnography in patients from Santa Marta, Colombia. An accuracy study of diagnostic tests with a test-based approach was designed. Seven hundred sixty-two adults referred for polysomnography to evaluate OSAHS were included in the research. They were aged between 18 and 94 years old (mean=47.2, SD=13.4), 63.3% were men, and 46.5% were classified as obese. The STOP-Bang performance was compared against the best reference criterion, the hypopnea/apnea index determined by polysomnography. The diagnosis of OSAHS was confirmed in 461 (60.5%) and corroborated in 301 (39.5%). The area under the curve was 0.70 (95%CI 0.66-0.74), and the best cut-off point was 4, with a sensitivity of 79.2%, a specificity of 53.5%, the positive predictive value of 72.2%, the negative predictive value of 62.6%, positive likelihood ratio was 1.70, negative likelihood ratio was 0.39; OR=4.08 (CI95% 2.99-5.56) and Cohen's kappa of 0.33. As conclusions, performance indicators show that STOP-Bang...\",\"PeriodicalId\":0,\"journal\":{\"name\":\"\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0,\"publicationDate\":\"2021-11-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21676/2389783x.4371\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21676/2389783x.4371","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

STOP-Bang已被推广为识别内科和外科患者的阻塞性睡眠呼吸暂停低通气综合征(OSAHS)的有价值的工具。然而,其在哥伦比亚样品中的表现尚不清楚。本研究的目的是确定STOP-Bang指数与哥伦比亚圣玛尔塔患者多导睡眠图研究的临床表现。设计了一种基于测试方法的诊断测试的准确性研究。762名接受多导睡眠描记术评估OSAHS的成年人被纳入研究。年龄在18 ~ 94岁之间(平均47.2岁,SD=13.4),男性占63.3%,肥胖占46.5%。将STOP-Bang表现与最佳参考标准进行比较,即由多导睡眠图确定的低呼吸/呼吸暂停指数。确诊OSAHS者461例(60.5%),确诊者301例(39.5%)。曲线下面积为0.70 (95%CI 0.66-0.74),最佳分界点为4,敏感性为79.2%,特异性为53.5%,阳性预测值为72.2%,阴性预测值为62.6%,阳性似然比为1.70,阴性似然比为0.39;OR=4.08 (CI95% 2.99 ~ 5.56), Cohen’s kappa为0.33。综上所述,性能指标表明,STOP-Bang…
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享
查看原文
STOP-Bang as a predictor of obstructive sleep apnea-hypopnea syndrome in outpatients
The STOP-Bang has been promoted as a valuable tool for identifying obstructive sleep apnea-hypopnea syndrome (OSAHS) in medical and surgical patients. However, its performance in Colombian samples is unknown. The objective of this study was to determine the clinimetric performance of the STOP-Bang index versus the study of polysomnography in patients from Santa Marta, Colombia. An accuracy study of diagnostic tests with a test-based approach was designed. Seven hundred sixty-two adults referred for polysomnography to evaluate OSAHS were included in the research. They were aged between 18 and 94 years old (mean=47.2, SD=13.4), 63.3% were men, and 46.5% were classified as obese. The STOP-Bang performance was compared against the best reference criterion, the hypopnea/apnea index determined by polysomnography. The diagnosis of OSAHS was confirmed in 461 (60.5%) and corroborated in 301 (39.5%). The area under the curve was 0.70 (95%CI 0.66-0.74), and the best cut-off point was 4, with a sensitivity of 79.2%, a specificity of 53.5%, the positive predictive value of 72.2%, the negative predictive value of 62.6%, positive likelihood ratio was 1.70, negative likelihood ratio was 0.39; OR=4.08 (CI95% 2.99-5.56) and Cohen's kappa of 0.33. As conclusions, performance indicators show that STOP-Bang...
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信