{"title":"复合树脂CAD/CAM牙冠中牙尖倾斜度和胶合剂对断裂载荷值的影响。","authors":"Gen Kuroishi, Mamoru Yotsuya, Syuntaro Nomoto, R. Hisanaga, Toru Sato","doi":"10.2209/tdcpublication.2020-0017","DOIUrl":null,"url":null,"abstract":"The purpose of this study was to evaluate whether change in cuspal inclination influences the fracture load values of composite resin computer-aided design/computer-aided manufacturing (CAD/CAM) crowns. Abutment teeth and CAD/CAM crowns were prepared as they would be for treating a mandibular first premolar with two cusps. The CAD/CAM crowns were designed so that 1) the principal stress lines would be radially distributed from the two points of contact with the indenter to the occlusal area of the abutment (Type I), or 2) the principal stress lines would pass outside the occlusal area of the abutment (Types II and III). The CAD/CAM crowns were mounted on the abutments using one of two types of resin or polycarboxylate cement. Fracture load values were measured using a universal tester. The Type I CAD/CAM crowns exhibited the highest mean fracture load value, followed by the Type II crowns and then the Type III crowns, with significant differences seen between all types (p<0.05). The luting agent used (resin or polycarboxylate cement) showed no effect on the fracture load value. With the Type II and Type III crowns, significant differences in the fracture load value were observed between the Super-Bond and Hy-Bond polycarboxylate cement groups (p<0.05).","PeriodicalId":45490,"journal":{"name":"Bulletin of Tokyo Dental College","volume":" ","pages":""},"PeriodicalIF":0.5000,"publicationDate":"2022-05-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Effects of Cuspal Inclination and Luting Agent on Fracture Load Values in Composite Resin CAD/CAM Crowns.\",\"authors\":\"Gen Kuroishi, Mamoru Yotsuya, Syuntaro Nomoto, R. Hisanaga, Toru Sato\",\"doi\":\"10.2209/tdcpublication.2020-0017\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The purpose of this study was to evaluate whether change in cuspal inclination influences the fracture load values of composite resin computer-aided design/computer-aided manufacturing (CAD/CAM) crowns. Abutment teeth and CAD/CAM crowns were prepared as they would be for treating a mandibular first premolar with two cusps. The CAD/CAM crowns were designed so that 1) the principal stress lines would be radially distributed from the two points of contact with the indenter to the occlusal area of the abutment (Type I), or 2) the principal stress lines would pass outside the occlusal area of the abutment (Types II and III). The CAD/CAM crowns were mounted on the abutments using one of two types of resin or polycarboxylate cement. Fracture load values were measured using a universal tester. The Type I CAD/CAM crowns exhibited the highest mean fracture load value, followed by the Type II crowns and then the Type III crowns, with significant differences seen between all types (p<0.05). The luting agent used (resin or polycarboxylate cement) showed no effect on the fracture load value. With the Type II and Type III crowns, significant differences in the fracture load value were observed between the Super-Bond and Hy-Bond polycarboxylate cement groups (p<0.05).\",\"PeriodicalId\":45490,\"journal\":{\"name\":\"Bulletin of Tokyo Dental College\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2022-05-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bulletin of Tokyo Dental College\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2209/tdcpublication.2020-0017\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bulletin of Tokyo Dental College","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2209/tdcpublication.2020-0017","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
Effects of Cuspal Inclination and Luting Agent on Fracture Load Values in Composite Resin CAD/CAM Crowns.
The purpose of this study was to evaluate whether change in cuspal inclination influences the fracture load values of composite resin computer-aided design/computer-aided manufacturing (CAD/CAM) crowns. Abutment teeth and CAD/CAM crowns were prepared as they would be for treating a mandibular first premolar with two cusps. The CAD/CAM crowns were designed so that 1) the principal stress lines would be radially distributed from the two points of contact with the indenter to the occlusal area of the abutment (Type I), or 2) the principal stress lines would pass outside the occlusal area of the abutment (Types II and III). The CAD/CAM crowns were mounted on the abutments using one of two types of resin or polycarboxylate cement. Fracture load values were measured using a universal tester. The Type I CAD/CAM crowns exhibited the highest mean fracture load value, followed by the Type II crowns and then the Type III crowns, with significant differences seen between all types (p<0.05). The luting agent used (resin or polycarboxylate cement) showed no effect on the fracture load value. With the Type II and Type III crowns, significant differences in the fracture load value were observed between the Super-Bond and Hy-Bond polycarboxylate cement groups (p<0.05).