{"title":"用于跟踪外泌体动态通信的器官芯片微流控系统","authors":"Abhimanyu Thakur","doi":"10.1016/j.onano.2023.100179","DOIUrl":null,"url":null,"abstract":"<div><p>Organ-on-a-chip microfluid systems (OCMS) are miniaturized three-dimension models of human tissue and organ, designed to recapitulate the crucial physiological and biological parameters of their corresponding <em>in vivo</em> parts. They have emerged as a powerful multifunctional tool for various applications such as personalized medicine, drug screening, due to its ability to show biomimetic composition, designs, and functions. Recently, OCMS have been employed to model and decode inter-organ communication via exosomes. Exosomes are biological nanovesicles with approximately 30-200 nm diameter, released from most of the cell types and participate in various cellular functions via intracellular communication and by carrying different cargoes including protein, and nucleic acids. Under pathological conditions such as cancer, the release of exosomes enhances tremendously, which are either fused or internalized by the recipient cells to elicit specific biological responses. The research pertaining to the exosomal communication has employed different methods for characterizing their release by the donor cells and uptake by the recipient cells, such as nano tracking analyzer, protein quantification, transmission electron microscopy (TEM), scanning EM (SEM), and immunogold-EM, exosome labeling kits, microbead-based flow cytometry. However, the research associated with the regulation of exosomal release and uptake has been impeded by the dearth of advanced techniques for capturing dynamics of exosomes. Here in, we discuss the advances in biosensing for tracking exosomal dynamic communication in OCMS, which will open new avenues of exosomal research using microfluidic engineering for modeling intracellular communication in OCMS.</p></div>","PeriodicalId":37785,"journal":{"name":"OpenNano","volume":"13 ","pages":"Article 100179"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Organ-on-a-Chip Microfluidic Systems for Tracking Exosomal Dynamic Communication\",\"authors\":\"Abhimanyu Thakur\",\"doi\":\"10.1016/j.onano.2023.100179\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Organ-on-a-chip microfluid systems (OCMS) are miniaturized three-dimension models of human tissue and organ, designed to recapitulate the crucial physiological and biological parameters of their corresponding <em>in vivo</em> parts. They have emerged as a powerful multifunctional tool for various applications such as personalized medicine, drug screening, due to its ability to show biomimetic composition, designs, and functions. Recently, OCMS have been employed to model and decode inter-organ communication via exosomes. Exosomes are biological nanovesicles with approximately 30-200 nm diameter, released from most of the cell types and participate in various cellular functions via intracellular communication and by carrying different cargoes including protein, and nucleic acids. Under pathological conditions such as cancer, the release of exosomes enhances tremendously, which are either fused or internalized by the recipient cells to elicit specific biological responses. The research pertaining to the exosomal communication has employed different methods for characterizing their release by the donor cells and uptake by the recipient cells, such as nano tracking analyzer, protein quantification, transmission electron microscopy (TEM), scanning EM (SEM), and immunogold-EM, exosome labeling kits, microbead-based flow cytometry. However, the research associated with the regulation of exosomal release and uptake has been impeded by the dearth of advanced techniques for capturing dynamics of exosomes. Here in, we discuss the advances in biosensing for tracking exosomal dynamic communication in OCMS, which will open new avenues of exosomal research using microfluidic engineering for modeling intracellular communication in OCMS.</p></div>\",\"PeriodicalId\":37785,\"journal\":{\"name\":\"OpenNano\",\"volume\":\"13 \",\"pages\":\"Article 100179\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"OpenNano\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2352952023000580\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Pharmacology, Toxicology and Pharmaceutics\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"OpenNano","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352952023000580","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Pharmacology, Toxicology and Pharmaceutics","Score":null,"Total":0}
Organ-on-a-Chip Microfluidic Systems for Tracking Exosomal Dynamic Communication
Organ-on-a-chip microfluid systems (OCMS) are miniaturized three-dimension models of human tissue and organ, designed to recapitulate the crucial physiological and biological parameters of their corresponding in vivo parts. They have emerged as a powerful multifunctional tool for various applications such as personalized medicine, drug screening, due to its ability to show biomimetic composition, designs, and functions. Recently, OCMS have been employed to model and decode inter-organ communication via exosomes. Exosomes are biological nanovesicles with approximately 30-200 nm diameter, released from most of the cell types and participate in various cellular functions via intracellular communication and by carrying different cargoes including protein, and nucleic acids. Under pathological conditions such as cancer, the release of exosomes enhances tremendously, which are either fused or internalized by the recipient cells to elicit specific biological responses. The research pertaining to the exosomal communication has employed different methods for characterizing their release by the donor cells and uptake by the recipient cells, such as nano tracking analyzer, protein quantification, transmission electron microscopy (TEM), scanning EM (SEM), and immunogold-EM, exosome labeling kits, microbead-based flow cytometry. However, the research associated with the regulation of exosomal release and uptake has been impeded by the dearth of advanced techniques for capturing dynamics of exosomes. Here in, we discuss the advances in biosensing for tracking exosomal dynamic communication in OCMS, which will open new avenues of exosomal research using microfluidic engineering for modeling intracellular communication in OCMS.
期刊介绍:
OpenNano is an internationally peer-reviewed and open access journal publishing high-quality review articles and original research papers on the burgeoning area of nanopharmaceutics and nanosized delivery systems for drugs, genes, and imaging agents. The Journal publishes basic, translational and clinical research as well as methodological papers and aims to bring together chemists, biochemists, cell biologists, material scientists, pharmaceutical scientists, pharmacologists, clinicians and all others working in this exciting and challenging area.