一种用于医学伽马射线成像的双光子符合检测方法

IF 1.2 Q3 Computer Science
M. Uenomachi, K. Shimazoe, H. Takahashi
{"title":"一种用于医学伽马射线成像的双光子符合检测方法","authors":"M. Uenomachi, K. Shimazoe, H. Takahashi","doi":"10.2478/bioal-2022-0080","DOIUrl":null,"url":null,"abstract":"\n Cascade nuclides emit two or more gamma rays successively through an intermediate state. The coincidence detection of cascade gamma rays provides several advantages in gamma-ray imaging. In this review article, three applications of the double photon coincidence method are reviewed. Double-photon emission imaging with mechanical collimators and Compton double-photon emission imaging can identify radioactive source positions with their angular-resolving detectors, and reduce the crosstalk between nuclides. In addition, a novel method of coincidence Compton imaging is proposed by taking coincidence detection between a Compton event and a photopeak events. Although this type of coincidence Compton imaging cannot specify the location, it can be useful in multi-nuclide Compton imaging.","PeriodicalId":42620,"journal":{"name":"Bio-Algorithms and Med-Systems","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A double photon coincidence detection method for medical gamma-ray imaging\",\"authors\":\"M. Uenomachi, K. Shimazoe, H. Takahashi\",\"doi\":\"10.2478/bioal-2022-0080\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n Cascade nuclides emit two or more gamma rays successively through an intermediate state. The coincidence detection of cascade gamma rays provides several advantages in gamma-ray imaging. In this review article, three applications of the double photon coincidence method are reviewed. Double-photon emission imaging with mechanical collimators and Compton double-photon emission imaging can identify radioactive source positions with their angular-resolving detectors, and reduce the crosstalk between nuclides. In addition, a novel method of coincidence Compton imaging is proposed by taking coincidence detection between a Compton event and a photopeak events. Although this type of coincidence Compton imaging cannot specify the location, it can be useful in multi-nuclide Compton imaging.\",\"PeriodicalId\":42620,\"journal\":{\"name\":\"Bio-Algorithms and Med-Systems\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2022-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bio-Algorithms and Med-Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2478/bioal-2022-0080\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Computer Science\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bio-Algorithms and Med-Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/bioal-2022-0080","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Computer Science","Score":null,"Total":0}
引用次数: 2

摘要

级联核素通过中间状态连续发射两种或两种以上的伽马射线。级联伽马射线的重合检测在伽马射线成像中有几个优点。本文综述了双光子符合方法的三种应用。机械准直器双光子发射成像和康普顿双光子发射成像可以利用角分辨探测器识别放射源位置,减少核素间的串扰。此外,提出了一种新的康普顿重合成像方法,即对康普顿事件和光峰事件进行重合检测。虽然这种类型的巧合康普顿成像不能指定位置,但它在多核素康普顿成像中是有用的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A double photon coincidence detection method for medical gamma-ray imaging
Cascade nuclides emit two or more gamma rays successively through an intermediate state. The coincidence detection of cascade gamma rays provides several advantages in gamma-ray imaging. In this review article, three applications of the double photon coincidence method are reviewed. Double-photon emission imaging with mechanical collimators and Compton double-photon emission imaging can identify radioactive source positions with their angular-resolving detectors, and reduce the crosstalk between nuclides. In addition, a novel method of coincidence Compton imaging is proposed by taking coincidence detection between a Compton event and a photopeak events. Although this type of coincidence Compton imaging cannot specify the location, it can be useful in multi-nuclide Compton imaging.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Bio-Algorithms and Med-Systems
Bio-Algorithms and Med-Systems MATHEMATICAL & COMPUTATIONAL BIOLOGY-
CiteScore
3.80
自引率
0.00%
发文量
3
期刊介绍: The journal Bio-Algorithms and Med-Systems (BAMS), edited by the Jagiellonian University Medical College, provides a forum for the exchange of information in the interdisciplinary fields of computational methods applied in medicine, presenting new algorithms and databases that allows the progress in collaborations between medicine, informatics, physics, and biochemistry. Projects linking specialists representing these disciplines are welcome to be published in this Journal. Articles in BAMS are published in English. Topics Bioinformatics Systems biology Telemedicine E-Learning in Medicine Patient''s electronic record Image processing Medical databases.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信