一种灵活的设计框架,用于设计具有可调节各向异性特性的分级多孔骨支架。

K. Cheikho, J. Ganghoffer, A. Baldit, E. Labbe, S. Alix, H. Kerdjoudj, C. Mauprivez, A. Lebée, C. Laurent
{"title":"一种灵活的设计框架,用于设计具有可调节各向异性特性的分级多孔骨支架。","authors":"K. Cheikho, J. Ganghoffer, A. Baldit, E. Labbe, S. Alix, H. Kerdjoudj, C. Mauprivez, A. Lebée, C. Laurent","doi":"10.2139/ssrn.4147190","DOIUrl":null,"url":null,"abstract":"Since the success of bone regenerative medicine depends on scaffold morphological and mechanical properties, numerous scaffolds designs have been proposed in the last decade, including graded structures that are suited to enhance tissue ingrowth. Most of these structures are based either on foams with a random pore definition, or on the periodic repetition of a unit cell (UC). These approaches are limited by the range of target porosities and obtained effective mechanical properties, and do not permit to easily generate a pore size gradient from the core to the periphery of the scaffold. In opposition, the objective of the present contribution is to propose a flexible design framework to generate various three-dimensional (3D) scaffolds structures including cylindrical graded scaffolds from the definition of a UC by making use of a non-periodic mapping. Conformal mappings are firstly used to generate graded circular cross-sections, while 3D structures are then obtained by stacking the cross-sections with or without a twist between different scaffold layers. The effective mechanical properties of different scaffold configurations are presented and compared using an energy-based efficient numerical method, pointing out the versatility of the design procedure to separately govern longitudinal and transverse anisotropic scaffold properties. Among these configurations, a helical structure exhibiting couplings between transverse and longitudinal properties is proposed and permits to extend the adaptability of the proposed framework. In order to investigate the capacity of common additive manufacturing techniques to fabricate the proposed structures, a subset of these configurations is elaborated using a standard SLA setup, and subjected to experimental mechanical testing. Despite observed geometric differences between the initial design and the actual obtained structures, the effective properties are satisfyingly predicted by the proposed computational method. Promising perspectives are offered concerning the design of self-fitting scaffolds with on-demand properties depending on the clinical application.","PeriodicalId":94117,"journal":{"name":"Journal of the mechanical behavior of biomedical materials","volume":"140 1","pages":"105727"},"PeriodicalIF":0.0000,"publicationDate":"2023-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A flexible design framework to design graded porous bone scaffolds with adjustable anisotropic properties.\",\"authors\":\"K. Cheikho, J. Ganghoffer, A. Baldit, E. Labbe, S. Alix, H. Kerdjoudj, C. Mauprivez, A. Lebée, C. Laurent\",\"doi\":\"10.2139/ssrn.4147190\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Since the success of bone regenerative medicine depends on scaffold morphological and mechanical properties, numerous scaffolds designs have been proposed in the last decade, including graded structures that are suited to enhance tissue ingrowth. Most of these structures are based either on foams with a random pore definition, or on the periodic repetition of a unit cell (UC). These approaches are limited by the range of target porosities and obtained effective mechanical properties, and do not permit to easily generate a pore size gradient from the core to the periphery of the scaffold. In opposition, the objective of the present contribution is to propose a flexible design framework to generate various three-dimensional (3D) scaffolds structures including cylindrical graded scaffolds from the definition of a UC by making use of a non-periodic mapping. Conformal mappings are firstly used to generate graded circular cross-sections, while 3D structures are then obtained by stacking the cross-sections with or without a twist between different scaffold layers. The effective mechanical properties of different scaffold configurations are presented and compared using an energy-based efficient numerical method, pointing out the versatility of the design procedure to separately govern longitudinal and transverse anisotropic scaffold properties. Among these configurations, a helical structure exhibiting couplings between transverse and longitudinal properties is proposed and permits to extend the adaptability of the proposed framework. In order to investigate the capacity of common additive manufacturing techniques to fabricate the proposed structures, a subset of these configurations is elaborated using a standard SLA setup, and subjected to experimental mechanical testing. Despite observed geometric differences between the initial design and the actual obtained structures, the effective properties are satisfyingly predicted by the proposed computational method. Promising perspectives are offered concerning the design of self-fitting scaffolds with on-demand properties depending on the clinical application.\",\"PeriodicalId\":94117,\"journal\":{\"name\":\"Journal of the mechanical behavior of biomedical materials\",\"volume\":\"140 1\",\"pages\":\"105727\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the mechanical behavior of biomedical materials\",\"FirstCategoryId\":\"0\",\"ListUrlMain\":\"https://doi.org/10.2139/ssrn.4147190\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the mechanical behavior of biomedical materials","FirstCategoryId":"0","ListUrlMain":"https://doi.org/10.2139/ssrn.4147190","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

由于骨再生医学的成功取决于支架的形态和力学性能,在过去十年中,已经提出了许多支架设计,包括适合增强组织向内生长的分级结构。这些结构中的大多数基于具有随机孔隙定义的泡沫,或者基于晶胞(UC)的周期性重复。这些方法受到目标孔隙率的范围和获得的有效机械性能的限制,并且不允许容易地产生从支架的核心到外围的孔径梯度。相反,本贡献的目的是提出一种灵活的设计框架,通过使用非周期映射从UC的定义生成各种三维(3D)支架结构,包括圆柱形分级支架。保角映射首先用于生成渐变圆形横截面,然后通过在不同支架层之间堆叠具有或不具有扭曲的横截面来获得3D结构。采用基于能量的高效数值方法,对不同支架结构的有效力学性能进行了介绍和比较,指出了设计程序的通用性,可以分别控制纵向和横向各向异性支架的性能。在这些配置中,提出了一种在横向和纵向特性之间表现出耦合的螺旋结构,并允许扩展所提出的框架的适应性。为了研究普通增材制造技术制造所提出结构的能力,使用标准SLA设置详细阐述了这些配置的子集,并进行了实验机械测试。尽管观察到初始设计和实际获得的结构之间存在几何差异,但所提出的计算方法还是令人满意地预测了有效性能。根据临床应用的不同,提供了具有按需性能的自适配支架的设计前景。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A flexible design framework to design graded porous bone scaffolds with adjustable anisotropic properties.
Since the success of bone regenerative medicine depends on scaffold morphological and mechanical properties, numerous scaffolds designs have been proposed in the last decade, including graded structures that are suited to enhance tissue ingrowth. Most of these structures are based either on foams with a random pore definition, or on the periodic repetition of a unit cell (UC). These approaches are limited by the range of target porosities and obtained effective mechanical properties, and do not permit to easily generate a pore size gradient from the core to the periphery of the scaffold. In opposition, the objective of the present contribution is to propose a flexible design framework to generate various three-dimensional (3D) scaffolds structures including cylindrical graded scaffolds from the definition of a UC by making use of a non-periodic mapping. Conformal mappings are firstly used to generate graded circular cross-sections, while 3D structures are then obtained by stacking the cross-sections with or without a twist between different scaffold layers. The effective mechanical properties of different scaffold configurations are presented and compared using an energy-based efficient numerical method, pointing out the versatility of the design procedure to separately govern longitudinal and transverse anisotropic scaffold properties. Among these configurations, a helical structure exhibiting couplings between transverse and longitudinal properties is proposed and permits to extend the adaptability of the proposed framework. In order to investigate the capacity of common additive manufacturing techniques to fabricate the proposed structures, a subset of these configurations is elaborated using a standard SLA setup, and subjected to experimental mechanical testing. Despite observed geometric differences between the initial design and the actual obtained structures, the effective properties are satisfyingly predicted by the proposed computational method. Promising perspectives are offered concerning the design of self-fitting scaffolds with on-demand properties depending on the clinical application.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信