{"title":"在三级转诊中心使用可回收下腔静脉滤器的十年经验。","authors":"G. Tse, T. Cleveland, S. Goode","doi":"10.5152/dir.2016.16022","DOIUrl":null,"url":null,"abstract":"PURPOSE\nA significant proportion of patients undergoing surgery have an increased incidence of acute pulmonary embolus (PE). We analyzed all patients who had a retrievable inferior vena cava (IVC) filter placed preoperatively for PE prophylaxis and investigated the long-term outcomes of the patients who did not have their filter removed.\n\n\nMETHODS\nPatients who underwent retrievable IVC filter insertion and attempted removal were identified from the radiology information systems database in a large tertiary referral university teaching hospital. Results of all clinical investigations (including computed tomography, magnetic resonance imaging, ultrasonography, and plain radiography) while the IVC filters were in situ were reviewed.\n\n\nRESULTS\nIn total, 393 retrievable IVC filters were inserted, 254 with the indication of preoperative thromboembolic prophylaxis. Recurrent PE was reported in five patients (1.9%) despite the IVC filter. Of the 254 retrievable filters inserted prior to surgery, an attempt at retrieval was made in 168 filters (66.1%). Successful retrieval at the first attempt occurred in 143 cases (85.1%), while 25 cases failed or were aborted (14.9%). No attempt at retrieval was made in 86 (33.9%) patients and a significant proportion of these patients had undergone cancer surgery (P < 0.0107). In those patients where there was no attempt at retrieval, there was an association between cancer surgery and a shorter absolute survival time (P < 0.0001).\n\n\nCONCLUSION\nThe majority of attempted filter retrievals were successful, and a proportion of nonretrieved IVC filters are accounted for in patients who underwent cancer surgery and ultimately died with the filter in situ. A departmental protocol is recommended to ensure the filter is removed where appropriate and possible.","PeriodicalId":50582,"journal":{"name":"Diagnostic and Interventional Radiology","volume":"23 2 1","pages":"144-149"},"PeriodicalIF":2.1000,"publicationDate":"2017-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.5152/dir.2016.16022","citationCount":"4","resultStr":"{\"title\":\"Ten-year experience of retrievable inferior vena cava filters in a tertiary referral center.\",\"authors\":\"G. Tse, T. Cleveland, S. Goode\",\"doi\":\"10.5152/dir.2016.16022\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"PURPOSE\\nA significant proportion of patients undergoing surgery have an increased incidence of acute pulmonary embolus (PE). We analyzed all patients who had a retrievable inferior vena cava (IVC) filter placed preoperatively for PE prophylaxis and investigated the long-term outcomes of the patients who did not have their filter removed.\\n\\n\\nMETHODS\\nPatients who underwent retrievable IVC filter insertion and attempted removal were identified from the radiology information systems database in a large tertiary referral university teaching hospital. Results of all clinical investigations (including computed tomography, magnetic resonance imaging, ultrasonography, and plain radiography) while the IVC filters were in situ were reviewed.\\n\\n\\nRESULTS\\nIn total, 393 retrievable IVC filters were inserted, 254 with the indication of preoperative thromboembolic prophylaxis. Recurrent PE was reported in five patients (1.9%) despite the IVC filter. Of the 254 retrievable filters inserted prior to surgery, an attempt at retrieval was made in 168 filters (66.1%). Successful retrieval at the first attempt occurred in 143 cases (85.1%), while 25 cases failed or were aborted (14.9%). No attempt at retrieval was made in 86 (33.9%) patients and a significant proportion of these patients had undergone cancer surgery (P < 0.0107). In those patients where there was no attempt at retrieval, there was an association between cancer surgery and a shorter absolute survival time (P < 0.0001).\\n\\n\\nCONCLUSION\\nThe majority of attempted filter retrievals were successful, and a proportion of nonretrieved IVC filters are accounted for in patients who underwent cancer surgery and ultimately died with the filter in situ. A departmental protocol is recommended to ensure the filter is removed where appropriate and possible.\",\"PeriodicalId\":50582,\"journal\":{\"name\":\"Diagnostic and Interventional Radiology\",\"volume\":\"23 2 1\",\"pages\":\"144-149\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2017-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.5152/dir.2016.16022\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Diagnostic and Interventional Radiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.5152/dir.2016.16022\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostic and Interventional Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5152/dir.2016.16022","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
Ten-year experience of retrievable inferior vena cava filters in a tertiary referral center.
PURPOSE
A significant proportion of patients undergoing surgery have an increased incidence of acute pulmonary embolus (PE). We analyzed all patients who had a retrievable inferior vena cava (IVC) filter placed preoperatively for PE prophylaxis and investigated the long-term outcomes of the patients who did not have their filter removed.
METHODS
Patients who underwent retrievable IVC filter insertion and attempted removal were identified from the radiology information systems database in a large tertiary referral university teaching hospital. Results of all clinical investigations (including computed tomography, magnetic resonance imaging, ultrasonography, and plain radiography) while the IVC filters were in situ were reviewed.
RESULTS
In total, 393 retrievable IVC filters were inserted, 254 with the indication of preoperative thromboembolic prophylaxis. Recurrent PE was reported in five patients (1.9%) despite the IVC filter. Of the 254 retrievable filters inserted prior to surgery, an attempt at retrieval was made in 168 filters (66.1%). Successful retrieval at the first attempt occurred in 143 cases (85.1%), while 25 cases failed or were aborted (14.9%). No attempt at retrieval was made in 86 (33.9%) patients and a significant proportion of these patients had undergone cancer surgery (P < 0.0107). In those patients where there was no attempt at retrieval, there was an association between cancer surgery and a shorter absolute survival time (P < 0.0001).
CONCLUSION
The majority of attempted filter retrievals were successful, and a proportion of nonretrieved IVC filters are accounted for in patients who underwent cancer surgery and ultimately died with the filter in situ. A departmental protocol is recommended to ensure the filter is removed where appropriate and possible.
期刊介绍:
Diagnostic and Interventional Radiology (Diagn Interv Radiol) is the open access, online-only official publication of Turkish Society of Radiology. It is published bimonthly and the journal’s publication language is English.
The journal is a medium for original articles, reviews, pictorial essays, technical notes related to all fields of diagnostic and interventional radiology.