CG02N分析仪在低剂量或高剂量肝素存在下准确测量全血纤维蛋白原水平

IF 0.7 4区 医学 Q4 HEMATOLOGY
Yoshihiko Nakamura, Junichi Maruyama, Takehiro Umemura, Kota Hoshino, Yuhei Irie, Shinichi Morimoto, Yoshito Izutani, Hiroyasu Ishikura
{"title":"CG02N分析仪在低剂量或高剂量肝素存在下准确测量全血纤维蛋白原水平","authors":"Yoshihiko Nakamura, Junichi Maruyama, Takehiro Umemura, Kota Hoshino, Yuhei Irie, Shinichi Morimoto, Yoshito Izutani, Hiroyasu Ishikura","doi":"10.1007/s12288-023-01659-w","DOIUrl":null,"url":null,"abstract":"<p><p>Rapid fibrinogen (Fbg) evaluation is important in patients with massive bleeding during severe trauma and those undergoing major surgery. However, there are only a few studies on the point-of-care Fbg analyzer. In this study, we aimed to investigate the accuracy of Fbg level measured using CG02N, with whole blood contained in lithium-heparinized syringes with two different concentrations of heparin. Blood samples were collected in lithium-heparinized tubes, namely PREZA-PAK®II (low-dose heparin group [LG], 7 IU/mL) and Pro-Vent® Plus (high-dose heparin group [HG], 70.5 IU/mL). The Fbg levels in LG and HG were compared with those of citrated plasma Fbg (standard-Fbg). Strong correlations with respect to the Fbg level were observed between standard-Fbg and LG or HG (r = 0.968, p < 0.0001; r = 0.970, p < 0.0001, respectively). We demonstrated that the Fbg level in whole-blood samples was accurately assessed by CG02N and not affected by low- or high-dose heparin.</p>","PeriodicalId":49188,"journal":{"name":"Indian Journal of Hematology and Blood Transfusion","volume":null,"pages":null},"PeriodicalIF":0.7000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10831028/pdf/","citationCount":"0","resultStr":"{\"title\":\"CG02N Analyzer Accurately Measures Fibrinogen Level in Whole Blood in the Presence of Low- or High-Dose Heparin.\",\"authors\":\"Yoshihiko Nakamura, Junichi Maruyama, Takehiro Umemura, Kota Hoshino, Yuhei Irie, Shinichi Morimoto, Yoshito Izutani, Hiroyasu Ishikura\",\"doi\":\"10.1007/s12288-023-01659-w\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Rapid fibrinogen (Fbg) evaluation is important in patients with massive bleeding during severe trauma and those undergoing major surgery. However, there are only a few studies on the point-of-care Fbg analyzer. In this study, we aimed to investigate the accuracy of Fbg level measured using CG02N, with whole blood contained in lithium-heparinized syringes with two different concentrations of heparin. Blood samples were collected in lithium-heparinized tubes, namely PREZA-PAK®II (low-dose heparin group [LG], 7 IU/mL) and Pro-Vent® Plus (high-dose heparin group [HG], 70.5 IU/mL). The Fbg levels in LG and HG were compared with those of citrated plasma Fbg (standard-Fbg). Strong correlations with respect to the Fbg level were observed between standard-Fbg and LG or HG (r = 0.968, p < 0.0001; r = 0.970, p < 0.0001, respectively). We demonstrated that the Fbg level in whole-blood samples was accurately assessed by CG02N and not affected by low- or high-dose heparin.</p>\",\"PeriodicalId\":49188,\"journal\":{\"name\":\"Indian Journal of Hematology and Blood Transfusion\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10831028/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indian Journal of Hematology and Blood Transfusion\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s12288-023-01659-w\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/5/2 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"HEMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Hematology and Blood Transfusion","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s12288-023-01659-w","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/5/2 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

快速纤维蛋白原(Fbg)评估对于严重创伤和大手术中大量出血的患者非常重要。然而,关于床旁纤维蛋白原分析仪的研究却寥寥无几。在这项研究中,我们的目的是调查使用 CG02N 测量 Fbg 水平的准确性,全血包含在含有两种不同浓度肝素的锂肝素化注射器中。血样采集于锂肝素化试管中,即 PREZA-PAK®II(低剂量肝素组[LG],7 IU/mL)和 Pro-Vent® Plus(高剂量肝素组[HG],70.5 IU/mL)。LG 组和 HG 组的 Fbg 水平与枸橼酸化血浆 Fbg(标准 Fbg)的水平进行了比较。标准 Fbg 与 LG 或 HG 的 Fbg 水平有很强的相关性(r = 0.968,p
本文章由计算机程序翻译,如有差异,请以英文原文为准。

CG02N Analyzer Accurately Measures Fibrinogen Level in Whole Blood in the Presence of Low- or High-Dose Heparin.

CG02N Analyzer Accurately Measures Fibrinogen Level in Whole Blood in the Presence of Low- or High-Dose Heparin.

Rapid fibrinogen (Fbg) evaluation is important in patients with massive bleeding during severe trauma and those undergoing major surgery. However, there are only a few studies on the point-of-care Fbg analyzer. In this study, we aimed to investigate the accuracy of Fbg level measured using CG02N, with whole blood contained in lithium-heparinized syringes with two different concentrations of heparin. Blood samples were collected in lithium-heparinized tubes, namely PREZA-PAK®II (low-dose heparin group [LG], 7 IU/mL) and Pro-Vent® Plus (high-dose heparin group [HG], 70.5 IU/mL). The Fbg levels in LG and HG were compared with those of citrated plasma Fbg (standard-Fbg). Strong correlations with respect to the Fbg level were observed between standard-Fbg and LG or HG (r = 0.968, p < 0.0001; r = 0.970, p < 0.0001, respectively). We demonstrated that the Fbg level in whole-blood samples was accurately assessed by CG02N and not affected by low- or high-dose heparin.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.70
自引率
0.00%
发文量
82
审稿时长
>12 weeks
期刊介绍: Indian Journal of Hematology and Blood Transfusion is a medium for propagating and exchanging ideas within the medical community. It publishes peer-reviewed articles on a variety of aspects of clinical hematology, laboratory hematology and hemato-oncology. The journal exists to encourage scientific investigation in the study of blood in health and in disease; to promote and foster the exchange and diffusion of knowledge relating to blood and blood-forming tissues; and to provide a forum for discussion of hematological subjects on a national scale. The Journal is the official publication of The Indian Society of Hematology & Blood Transfusion.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示