液体有机闪烁体PYR5/DIPN和THIO5/DIPN的单能中子响应和光输出函数

IF 1.3 Q3 INSTRUMENTS & INSTRUMENTATION
Jaroslav Jánský, J. Janda, M. Kostal, Z. Matěj, T. Bily, Věra Mazánková, F. Mravec, F. Cvachovec
{"title":"液体有机闪烁体PYR5/DIPN和THIO5/DIPN的单能中子响应和光输出函数","authors":"Jaroslav Jánský, J. Janda, M. Kostal, Z. Matěj, T. Bily, Věra Mazánková, F. Mravec, F. Cvachovec","doi":"10.3390/qubs6020018","DOIUrl":null,"url":null,"abstract":"Liquid organic scintillators are important devices for measurements of neutron radiation. Currently, large-scale liquid organic scintillators have capabilities of detecting neutrons, but the determination of the neutron energy spectra is a challenge. This work aims to measure the responses of two liquid two-component scintillators to mono-energetic neutron radiation and to determine their light output function, which is necessary for proper neutron energy spectra determination. Both scintillators are composed of the solvent di-iso-propyl-naphthalene (DIPN) mixed isomers. The first scintillator, labeled PYR5/DIPN, contains the luminophore 1-phenyl-3-(2,4,6-trimethyl-phenyl)-2-pyrazoline with a concentration of 5 g/L. The second scintillator labeled THIO5/DIPN contains the luminophore 2,5-bis(5-tert-butyl-benzoxazol-2-yl)thiophene also with a concentration of 5 g/L. The responses to neutron energies of 1.5 MeV, 2.5 MeV, and 19 MeV are measured at PTB in Braunschweig. The responses to neutron energies of 2.45 MeV and 14 MeV were measured at CTU in Prague using DD and DT reactions. The responses to a silicon filtered beam were measured at Research Centre Řež. The measurements were processed using a two-parameter spectrometric system NGA-01 to discriminate neutrons from gamma rays. The obtained responses are dominated by recoil protons from elastic collisions of neutrons with hydrogen atoms. The edge of the response of recoil protons gives information about the light output of neutrons, compared to gamma rays for the same radiation energy. The light output function for protons in the PYR5/DIPN scintillator is L(Ep)=0.6294Ep−1.00(1−exp(−0.4933Ep0.95)). The light output function for protons in the THIO5/DIPN scintillator is L(Ep)=0.6323Ep−1.00(1−exp(−0.4986Ep0.9883)). The light output functions well resemble the standard shape, and they are quite similar to each other. That suggests a weak influence of the luminophore on the light output function. The light output functions are ready to be incorporated to the response matrix for the neutron energy spectra determination.","PeriodicalId":31879,"journal":{"name":"Quantum Beam Science","volume":" ","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2022-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Response to Mono-Energetic Neutrons and Light Output Function for Liquid Organic Scintillators PYR5/DIPN and THIO5/DIPN\",\"authors\":\"Jaroslav Jánský, J. Janda, M. Kostal, Z. Matěj, T. Bily, Věra Mazánková, F. Mravec, F. Cvachovec\",\"doi\":\"10.3390/qubs6020018\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Liquid organic scintillators are important devices for measurements of neutron radiation. Currently, large-scale liquid organic scintillators have capabilities of detecting neutrons, but the determination of the neutron energy spectra is a challenge. This work aims to measure the responses of two liquid two-component scintillators to mono-energetic neutron radiation and to determine their light output function, which is necessary for proper neutron energy spectra determination. Both scintillators are composed of the solvent di-iso-propyl-naphthalene (DIPN) mixed isomers. The first scintillator, labeled PYR5/DIPN, contains the luminophore 1-phenyl-3-(2,4,6-trimethyl-phenyl)-2-pyrazoline with a concentration of 5 g/L. The second scintillator labeled THIO5/DIPN contains the luminophore 2,5-bis(5-tert-butyl-benzoxazol-2-yl)thiophene also with a concentration of 5 g/L. The responses to neutron energies of 1.5 MeV, 2.5 MeV, and 19 MeV are measured at PTB in Braunschweig. The responses to neutron energies of 2.45 MeV and 14 MeV were measured at CTU in Prague using DD and DT reactions. The responses to a silicon filtered beam were measured at Research Centre Řež. The measurements were processed using a two-parameter spectrometric system NGA-01 to discriminate neutrons from gamma rays. The obtained responses are dominated by recoil protons from elastic collisions of neutrons with hydrogen atoms. The edge of the response of recoil protons gives information about the light output of neutrons, compared to gamma rays for the same radiation energy. The light output function for protons in the PYR5/DIPN scintillator is L(Ep)=0.6294Ep−1.00(1−exp(−0.4933Ep0.95)). The light output function for protons in the THIO5/DIPN scintillator is L(Ep)=0.6323Ep−1.00(1−exp(−0.4986Ep0.9883)). The light output functions well resemble the standard shape, and they are quite similar to each other. That suggests a weak influence of the luminophore on the light output function. The light output functions are ready to be incorporated to the response matrix for the neutron energy spectra determination.\",\"PeriodicalId\":31879,\"journal\":{\"name\":\"Quantum Beam Science\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2022-05-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Quantum Beam Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/qubs6020018\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Quantum Beam Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/qubs6020018","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 1

摘要

液体有机闪烁体是测量中子辐射的重要装置。目前,大型液体有机闪烁体具有探测中子的能力,但中子能谱的确定是一个挑战。本文旨在测量两个液体双组分闪烁体对单能中子辐射的响应,并确定它们的光输出函数,这是正确测定中子能谱所必需的。两种闪烁体均由溶剂二异丙基萘(DIPN)混合异构体组成。第一个闪烁体标记为PYR5/DIPN,含有浓度为5 g/L的发光团1-苯基-3-(2,4,6-三甲基苯基)-2-吡唑啉。第二个闪烁体标记为THIO5/DIPN,含有发光体2,5-二(5-叔丁基苯并恶唑-2-基)噻吩,浓度也为5 g/L。在不伦瑞克的PTB上测量了对1.5 MeV、2.5 MeV和19 MeV中子能量的响应。在布拉格CTU用DD和DT反应测量了对2.45 MeV和14 MeV中子能量的响应。研究中心Řež测量了对硅过滤光束的响应。测量结果使用双参数光谱系统NGA-01进行处理,以区分中子和伽马射线。得到的响应主要是中子与氢原子弹性碰撞产生的反冲质子。反冲质子响应的边缘给出了与相同辐射能量的伽马射线相比,中子光输出的信息。PYR5/DIPN闪烁体中质子的光输出函数为L(Ep)=0.6294Ep−1.00(1−exp(−0.4933Ep0.95))。THIO5/DIPN闪烁体中质子的光输出函数为L(Ep)=0.6323Ep−1.00(1−exp(−0.4986Ep0.9883))。光输出功能很像标准形状,它们彼此非常相似。这表明发光团对光输出函数的影响很小。光输出函数已准备好纳入中子能谱测定的响应矩阵。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Response to Mono-Energetic Neutrons and Light Output Function for Liquid Organic Scintillators PYR5/DIPN and THIO5/DIPN
Liquid organic scintillators are important devices for measurements of neutron radiation. Currently, large-scale liquid organic scintillators have capabilities of detecting neutrons, but the determination of the neutron energy spectra is a challenge. This work aims to measure the responses of two liquid two-component scintillators to mono-energetic neutron radiation and to determine their light output function, which is necessary for proper neutron energy spectra determination. Both scintillators are composed of the solvent di-iso-propyl-naphthalene (DIPN) mixed isomers. The first scintillator, labeled PYR5/DIPN, contains the luminophore 1-phenyl-3-(2,4,6-trimethyl-phenyl)-2-pyrazoline with a concentration of 5 g/L. The second scintillator labeled THIO5/DIPN contains the luminophore 2,5-bis(5-tert-butyl-benzoxazol-2-yl)thiophene also with a concentration of 5 g/L. The responses to neutron energies of 1.5 MeV, 2.5 MeV, and 19 MeV are measured at PTB in Braunschweig. The responses to neutron energies of 2.45 MeV and 14 MeV were measured at CTU in Prague using DD and DT reactions. The responses to a silicon filtered beam were measured at Research Centre Řež. The measurements were processed using a two-parameter spectrometric system NGA-01 to discriminate neutrons from gamma rays. The obtained responses are dominated by recoil protons from elastic collisions of neutrons with hydrogen atoms. The edge of the response of recoil protons gives information about the light output of neutrons, compared to gamma rays for the same radiation energy. The light output function for protons in the PYR5/DIPN scintillator is L(Ep)=0.6294Ep−1.00(1−exp(−0.4933Ep0.95)). The light output function for protons in the THIO5/DIPN scintillator is L(Ep)=0.6323Ep−1.00(1−exp(−0.4986Ep0.9883)). The light output functions well resemble the standard shape, and they are quite similar to each other. That suggests a weak influence of the luminophore on the light output function. The light output functions are ready to be incorporated to the response matrix for the neutron energy spectra determination.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.80
自引率
28.60%
发文量
27
审稿时长
11 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信