Samuel Adebisi, S. Oyetunji
{"title":"采用单载波/多载波调制技术的编码/非编码电力线信道的数据速率曲线","authors":"Samuel Adebisi, S. Oyetunji","doi":"10.2478/ecce-2018-0003","DOIUrl":null,"url":null,"abstract":"Abstract The power-line communication (PLC) technique involves sending information through an electrical conductor for a commercial or domestic purpose. Lately, electronic means of communication have gained popularity for the transfer of information. Conversely, there is an increased requirement for more transmission media, like the use of power line as a communication channel for remote data delivery. This paper focuses on determining the data rate profile achievable using the single-carrier/multicarrier modulation techniques with Reed- Solomon concatenated convolutional (RS-CC) codes for data transmission through a power line channel. In this investigation, MATLAB/SIMULINK was used to explore a low-voltage power line as a communication channel for high data transmission rate. Data transmission was accomplished by utilizing a parametric model of a power line channel with the different kinds of noise considered in the simulation. In the designed power-line communication (PLC) system, single-carrier modulation offered a maximum of 14.4 Mbps reduction in the data rate when the uncoded 64-quadrature amplitude modulation (QAM) was compared to coded 64-QAM with 1/2 forward error correction (FEC). In the OFDM power-line communication (PLC) system, the decrease in the data rate was maximal at 39 Mbps when the uncoded 16-QAM was contrasted with the 16-QAM having 1/2 FEC. It was evident that the increased code rate of the PLC system using single-carrier and OFDM modulation implied increased data rate profiles","PeriodicalId":42365,"journal":{"name":"Electrical Control and Communication Engineering","volume":"14 1","pages":"23 - 29"},"PeriodicalIF":0.5000,"publicationDate":"2018-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Data rate profiles of coded/uncoded power line channel with single-carrier/multicarrier modulation techniques\",\"authors\":\"Samuel Adebisi, S. Oyetunji\",\"doi\":\"10.2478/ecce-2018-0003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract The power-line communication (PLC) technique involves sending information through an electrical conductor for a commercial or domestic purpose. Lately, electronic means of communication have gained popularity for the transfer of information. Conversely, there is an increased requirement for more transmission media, like the use of power line as a communication channel for remote data delivery. This paper focuses on determining the data rate profile achievable using the single-carrier/multicarrier modulation techniques with Reed- Solomon concatenated convolutional (RS-CC) codes for data transmission through a power line channel. In this investigation, MATLAB/SIMULINK was used to explore a low-voltage power line as a communication channel for high data transmission rate. Data transmission was accomplished by utilizing a parametric model of a power line channel with the different kinds of noise considered in the simulation. In the designed power-line communication (PLC) system, single-carrier modulation offered a maximum of 14.4 Mbps reduction in the data rate when the uncoded 64-quadrature amplitude modulation (QAM) was compared to coded 64-QAM with 1/2 forward error correction (FEC). In the OFDM power-line communication (PLC) system, the decrease in the data rate was maximal at 39 Mbps when the uncoded 16-QAM was contrasted with the 16-QAM having 1/2 FEC. It was evident that the increased code rate of the PLC system using single-carrier and OFDM modulation implied increased data rate profiles\",\"PeriodicalId\":42365,\"journal\":{\"name\":\"Electrical Control and Communication Engineering\",\"volume\":\"14 1\",\"pages\":\"23 - 29\"},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2018-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Electrical Control and Communication Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2478/ecce-2018-0003\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electrical Control and Communication Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/ecce-2018-0003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

摘要电力线通信(PLC)技术涉及通过导电体发送信息用于商业或家庭目的。最近,电子通信手段在信息传递方面越来越受欢迎。相反,对更多传输介质的需求也在增加,比如使用电力线作为远程数据传输的通信信道。本文的重点是确定使用里德-所罗门级联卷积码(RS-CC)的单载波/多载波调制技术通过电力线信道进行数据传输时可实现的数据速率分布。在本研究中,使用MATLAB/SIMULINK来探索一种低压电力线作为高数据传输速率的通信信道。利用电力线信道的参数模型,在仿真中考虑了不同类型的噪声,实现了数据传输。在设计的电力线通信(PLC)系统中,当将未编码的64正交幅度调制(QAM)与具有1/2前向纠错(FEC)的编码的64-QAM进行比较时,单载波调制在数据速率上提供了最大14.4Mbps的降低。在OFDM电力线通信(PLC)系统中,当未编码的16-QAM与具有1/2 FEC的16-QAM相比时,数据速率的下降在39Mbps时最大。很明显,使用单载波和OFDM调制的PLC系统的增加的码率意味着增加的数据速率分布
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Data rate profiles of coded/uncoded power line channel with single-carrier/multicarrier modulation techniques
Abstract The power-line communication (PLC) technique involves sending information through an electrical conductor for a commercial or domestic purpose. Lately, electronic means of communication have gained popularity for the transfer of information. Conversely, there is an increased requirement for more transmission media, like the use of power line as a communication channel for remote data delivery. This paper focuses on determining the data rate profile achievable using the single-carrier/multicarrier modulation techniques with Reed- Solomon concatenated convolutional (RS-CC) codes for data transmission through a power line channel. In this investigation, MATLAB/SIMULINK was used to explore a low-voltage power line as a communication channel for high data transmission rate. Data transmission was accomplished by utilizing a parametric model of a power line channel with the different kinds of noise considered in the simulation. In the designed power-line communication (PLC) system, single-carrier modulation offered a maximum of 14.4 Mbps reduction in the data rate when the uncoded 64-quadrature amplitude modulation (QAM) was compared to coded 64-QAM with 1/2 forward error correction (FEC). In the OFDM power-line communication (PLC) system, the decrease in the data rate was maximal at 39 Mbps when the uncoded 16-QAM was contrasted with the 16-QAM having 1/2 FEC. It was evident that the increased code rate of the PLC system using single-carrier and OFDM modulation implied increased data rate profiles
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Electrical Control and Communication Engineering
Electrical Control and Communication Engineering ENGINEERING, ELECTRICAL & ELECTRONIC-
自引率
14.30%
发文量
0
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信