{"title":"基于小型条纹管的三维成像激光雷达","authors":"L. Tian, Lingbin Shen, Yanhua Xue, Lin Chen, Ping Chen, Jinshou Tian, Wei Zhao","doi":"10.2478/msr-2023-0010","DOIUrl":null,"url":null,"abstract":"Abstract Streak Tube Imaging Lidar (STIL), with advantages of non-scanning working mode, small distortion, high image framing rate, high resolution in low contrast environment, compact structure, easy miniaturization and high reliability, has a wide range of applications in military, aerospace, space confrontation, attack and defense, and marine law enforcement. This article introduces the principle of single-slit and multi-slit streak tube imaging lidar. It also introduces a single-slit general streak camera that can be used for imaging lidar. In addition, a multi-slit miniaturized streak tube with a single-lens focusing system with a total length of about 200 mm has been designed. The results of the 3D electromagnetic simulation show that the effective photocathode area of this streak tube reaches 36 mm × 36 mm, the temporal resolution is better than 50 ps, the dynamic spatial resolution can reach 12 lp/mm, and the whole photocathode can accommodate at least 19 slits in the effective detection range. The streak tube has a meshless structure, which is highly reliable. The streak tube can be used to increase the field of view of the imaging lidar system, improve the reliability, and achieve system miniaturization.","PeriodicalId":49848,"journal":{"name":"Measurement Science Review","volume":"23 1","pages":"80 - 85"},"PeriodicalIF":1.0000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"3-D Imaging Lidar Based on Miniaturized Streak Tube\",\"authors\":\"L. Tian, Lingbin Shen, Yanhua Xue, Lin Chen, Ping Chen, Jinshou Tian, Wei Zhao\",\"doi\":\"10.2478/msr-2023-0010\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Streak Tube Imaging Lidar (STIL), with advantages of non-scanning working mode, small distortion, high image framing rate, high resolution in low contrast environment, compact structure, easy miniaturization and high reliability, has a wide range of applications in military, aerospace, space confrontation, attack and defense, and marine law enforcement. This article introduces the principle of single-slit and multi-slit streak tube imaging lidar. It also introduces a single-slit general streak camera that can be used for imaging lidar. In addition, a multi-slit miniaturized streak tube with a single-lens focusing system with a total length of about 200 mm has been designed. The results of the 3D electromagnetic simulation show that the effective photocathode area of this streak tube reaches 36 mm × 36 mm, the temporal resolution is better than 50 ps, the dynamic spatial resolution can reach 12 lp/mm, and the whole photocathode can accommodate at least 19 slits in the effective detection range. The streak tube has a meshless structure, which is highly reliable. The streak tube can be used to increase the field of view of the imaging lidar system, improve the reliability, and achieve system miniaturization.\",\"PeriodicalId\":49848,\"journal\":{\"name\":\"Measurement Science Review\",\"volume\":\"23 1\",\"pages\":\"80 - 85\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2023-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Measurement Science Review\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.2478/msr-2023-0010\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Measurement Science Review","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.2478/msr-2023-0010","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 1

摘要

摘要条纹管成像激光雷达(STIL)具有非扫描工作模式、失真小、图像成帧率高、低对比度环境下分辨率高、结构紧凑、易于小型化和可靠性高等优点,在军事、航空航天、空间对抗、攻防和海洋执法等领域有着广泛的应用。本文介绍了单狭缝和多狭缝条纹管成像激光雷达的原理。它还介绍了一种可用于激光雷达成像的单缝通用条纹相机。此外,还设计了一种具有单透镜聚焦系统的多狭缝微型条纹管,总长度约为200mm。三维电磁模拟结果表明,该条纹管的有效光电阴极面积达到36mm×36mm,时间分辨率优于50ps,动态空间分辨率可达12lp/mm,整个光电阴极在有效探测范围内至少可容纳19个狭缝。该条纹管具有无网格结构,可靠性高。条纹管可用于增加成像激光雷达系统的视场,提高可靠性,实现系统小型化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
3-D Imaging Lidar Based on Miniaturized Streak Tube
Abstract Streak Tube Imaging Lidar (STIL), with advantages of non-scanning working mode, small distortion, high image framing rate, high resolution in low contrast environment, compact structure, easy miniaturization and high reliability, has a wide range of applications in military, aerospace, space confrontation, attack and defense, and marine law enforcement. This article introduces the principle of single-slit and multi-slit streak tube imaging lidar. It also introduces a single-slit general streak camera that can be used for imaging lidar. In addition, a multi-slit miniaturized streak tube with a single-lens focusing system with a total length of about 200 mm has been designed. The results of the 3D electromagnetic simulation show that the effective photocathode area of this streak tube reaches 36 mm × 36 mm, the temporal resolution is better than 50 ps, the dynamic spatial resolution can reach 12 lp/mm, and the whole photocathode can accommodate at least 19 slits in the effective detection range. The streak tube has a meshless structure, which is highly reliable. The streak tube can be used to increase the field of view of the imaging lidar system, improve the reliability, and achieve system miniaturization.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Measurement Science Review
Measurement Science Review INSTRUMENTS & INSTRUMENTATION-
CiteScore
2.00
自引率
11.10%
发文量
37
审稿时长
4.8 months
期刊介绍: - theory of measurement - mathematical processing of measured data - measurement uncertainty minimisation - statistical methods in data evaluation and modelling - measurement as an interdisciplinary activity - measurement science in education - medical imaging methods, image processing - biosignal measurement, processing and analysis - model based biomeasurements - neural networks in biomeasurement - telemeasurement in biomedicine - measurement in nanomedicine - measurement of basic physical quantities - magnetic and electric fields measurements - measurement of geometrical and mechanical quantities - optical measuring methods - electromagnetic compatibility - measurement in material science
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信