传统与收缩型牙髓腔中的锉刀破损

IF 1.6 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
Donald K Mauney Iii, Antheunis Versluis, Daranee Tantbirojn, Harry T Cosby, Jeffrey G Phebus
{"title":"传统与收缩型牙髓腔中的锉刀破损","authors":"Donald K Mauney Iii, Antheunis Versluis, Daranee Tantbirojn, Harry T Cosby, Jeffrey G Phebus","doi":"10.14744/eej.2023.41033","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To compare rotations to failure and tip separation length of a nickel-titanium (Ni-Ti) rotary in- strument within a simulated mesio-buccal canal of a mandibular molar with a conventional or contracted endodontic cavity.</p><p><strong>Methods: </strong>Two identical lithium disilicate #30 crowns were milled. A conventional or contracted endodontic cavity was prepared. A custom glass tube was fabricated with taper and length replicating a mesio-buccal canal, including buccal and lingual curvature, and placed at the mesio-buccal orifice of each crown, held in a silicone mold. Instrumentation was simulated using 30/.04 Ni-Ti rotary files following manufacturer recommended 1.8 Nm torque and 500 RPM (n=20 per access type). Instrumentation was video recorded to determine time (sec- onds) and rotations to failure. The length of broken tips was measured. The experimental data were compared using a t-test (significance level 0.05). Stresses in the instruments were examined using finite element analysis.</p><p><strong>Results: </strong>Number of rotations to failure (mean±standard deviation) was 599±126 for conventional and 465±65 and for contracted access; tip separation lengths (mean±standard deviation) were 3.99±0.29 for conventional and 4.90±1.02 mm for contracted access. Number of rotations to failure and tip separation lengths were signifi- cantly different between the two access openings (p<0.001). Finite element analysis confirmed higher file curva- ture and accompanying higher stress levels with contracted access and the maximum stress further from the tip.</p><p><strong>Conclusion: </strong>Within the limitations of this study, the contracted access caused earlier failure of the Ni-Ti in- strument with longer tip separation lengths than the conventional access due to higher stresses towards the middle section of the instrument. (EEJ-2022-11-143).</p>","PeriodicalId":11860,"journal":{"name":"European Endodontic Journal","volume":"8 1","pages":"262-267"},"PeriodicalIF":1.6000,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10500211/pdf/","citationCount":"0","resultStr":"{\"title\":\"File Breakage in Conventional Versus Contracted Endodontic Cavities.\",\"authors\":\"Donald K Mauney Iii, Antheunis Versluis, Daranee Tantbirojn, Harry T Cosby, Jeffrey G Phebus\",\"doi\":\"10.14744/eej.2023.41033\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To compare rotations to failure and tip separation length of a nickel-titanium (Ni-Ti) rotary in- strument within a simulated mesio-buccal canal of a mandibular molar with a conventional or contracted endodontic cavity.</p><p><strong>Methods: </strong>Two identical lithium disilicate #30 crowns were milled. A conventional or contracted endodontic cavity was prepared. A custom glass tube was fabricated with taper and length replicating a mesio-buccal canal, including buccal and lingual curvature, and placed at the mesio-buccal orifice of each crown, held in a silicone mold. Instrumentation was simulated using 30/.04 Ni-Ti rotary files following manufacturer recommended 1.8 Nm torque and 500 RPM (n=20 per access type). Instrumentation was video recorded to determine time (sec- onds) and rotations to failure. The length of broken tips was measured. The experimental data were compared using a t-test (significance level 0.05). Stresses in the instruments were examined using finite element analysis.</p><p><strong>Results: </strong>Number of rotations to failure (mean±standard deviation) was 599±126 for conventional and 465±65 and for contracted access; tip separation lengths (mean±standard deviation) were 3.99±0.29 for conventional and 4.90±1.02 mm for contracted access. Number of rotations to failure and tip separation lengths were signifi- cantly different between the two access openings (p<0.001). Finite element analysis confirmed higher file curva- ture and accompanying higher stress levels with contracted access and the maximum stress further from the tip.</p><p><strong>Conclusion: </strong>Within the limitations of this study, the contracted access caused earlier failure of the Ni-Ti in- strument with longer tip separation lengths than the conventional access due to higher stresses towards the middle section of the instrument. (EEJ-2022-11-143).</p>\",\"PeriodicalId\":11860,\"journal\":{\"name\":\"European Endodontic Journal\",\"volume\":\"8 1\",\"pages\":\"262-267\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2023-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10500211/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Endodontic Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14744/eej.2023.41033\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Endodontic Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14744/eej.2023.41033","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的比较镍钛(Ni-Ti)旋转器械在模拟下颌磨牙中颊管内与常规牙髓腔或收缩牙髓腔内的旋转失败和尖端分离长度。方法将2个相同的30号二硅酸锂冠进行研磨。预备常规或收缩的牙髓腔。一个定制的玻璃管被制作成锥形和长度复制中颊管,包括颊和舌曲率,并放置在每个冠的中颊孔,在硅胶模具中固定。仪器使用30/.04进行模拟Ni-Ti旋转文件遵循制造商推荐的1.8 Nm扭矩和500 RPM(每个访问类型n=20)。仪器录像,以确定时间(秒)和旋转到故障。测量断头的长度。实验数据比较采用t检验(显著性水平0.05)。利用有限元分析对仪器中的应力进行了检测。结果常规组旋转失败次数(平均值±标准差)为599±126次,收缩组为465±65次;针尖分离长度(平均值±标准差):常规组为3.99±0.29 mm,收缩组为4.90±1.02 mm。旋转失败次数和尖端分离长度在两个通道开口之间有显著差异(p<0.001)。有限元分析证实了更高的锉曲率和伴随的更高的应力水平,与收缩的通道和最大应力远离尖端。结论在本研究的限制范围内,由于Ni-Ti仪器中间部分的应力较大,收缩通道比常规通道更早导致尖端分离长度较长的Ni-Ti仪器失效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
File Breakage in Conventional Versus Contracted Endodontic Cavities.

Objective: To compare rotations to failure and tip separation length of a nickel-titanium (Ni-Ti) rotary in- strument within a simulated mesio-buccal canal of a mandibular molar with a conventional or contracted endodontic cavity.

Methods: Two identical lithium disilicate #30 crowns were milled. A conventional or contracted endodontic cavity was prepared. A custom glass tube was fabricated with taper and length replicating a mesio-buccal canal, including buccal and lingual curvature, and placed at the mesio-buccal orifice of each crown, held in a silicone mold. Instrumentation was simulated using 30/.04 Ni-Ti rotary files following manufacturer recommended 1.8 Nm torque and 500 RPM (n=20 per access type). Instrumentation was video recorded to determine time (sec- onds) and rotations to failure. The length of broken tips was measured. The experimental data were compared using a t-test (significance level 0.05). Stresses in the instruments were examined using finite element analysis.

Results: Number of rotations to failure (mean±standard deviation) was 599±126 for conventional and 465±65 and for contracted access; tip separation lengths (mean±standard deviation) were 3.99±0.29 for conventional and 4.90±1.02 mm for contracted access. Number of rotations to failure and tip separation lengths were signifi- cantly different between the two access openings (p<0.001). Finite element analysis confirmed higher file curva- ture and accompanying higher stress levels with contracted access and the maximum stress further from the tip.

Conclusion: Within the limitations of this study, the contracted access caused earlier failure of the Ni-Ti in- strument with longer tip separation lengths than the conventional access due to higher stresses towards the middle section of the instrument. (EEJ-2022-11-143).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
European Endodontic Journal
European Endodontic Journal DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.40
自引率
5.60%
发文量
25
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信