Muhammad Faisal Javed, Manzar Zahra, Iqra Javed, Shahbaz Ahmad, T. Jabeen, Muhammad Ahmad
{"title":"反相高效液相色谱法测定丁二酸铁蛋白糖浆中尼泊金甲酯钠和尼泊金丙酯钠含量的建立与验证","authors":"Muhammad Faisal Javed, Manzar Zahra, Iqra Javed, Shahbaz Ahmad, T. Jabeen, Muhammad Ahmad","doi":"10.1556/1326.2022.00990","DOIUrl":null,"url":null,"abstract":"A new precise, selective and reliable reversed phase high performance liquid chromatographic (RP-HPLC) method has been developed and validated for the determination of Methyl paraben sodium (MPS) and Propyl paraben sodium (PPS) (preservatives) in Iron protein succinylate syrup. Optimized conditions were; Methanol: Water (65: 35) as mobile phase, UV/Vis detector at the wavelength of 254 nm and flow rate was set at 1.3 ml min−1. By applying the set of conditions, separation of components was carried out in less than 7 min for both the analytes. The method was validated according to International conference of Harmonization (ICH) guidelines and the analytical characteristic parameters of validation included specificity, limit of detection (LOD), limit of quantification, linearity, accuracy, precision and robustness were evaluated. The calibration curve was found to be linear in the range of 0.045 mg mL−1 to 0.075 mg mL−1 for Methyl paraben sodium and 0.015 mg mL−1 to 0.025 mg mL−1 for propyl paraben sodium with a correlation coefficient r2 > 0.999. Accuracy; reported as percentage recovery was found to be in the range of 98.71%–101.64% for Methyl paraben sodium and 99.85%–101.47% for Propyl paraben sodium at 80%, 100% and 120% concentration for both the analytes. The proposed method was found to be precise and robust when evaluated by variations in wavelength, mobile phase composition, temperature and analyst. The limit of detection (LOD) was found 0.001 mg mL−1 (3 ppm) for Methyl paraben sodium and 0.001 mg mL−1 (1 ppm) for Propyl paraben sodium.","PeriodicalId":7130,"journal":{"name":"Acta Chromatographica","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2023-01-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Development and validation of RP HPLC method for the estimation of methyl paraben sodium and propyl paraben sodium in iron protein succinylate syrup\",\"authors\":\"Muhammad Faisal Javed, Manzar Zahra, Iqra Javed, Shahbaz Ahmad, T. Jabeen, Muhammad Ahmad\",\"doi\":\"10.1556/1326.2022.00990\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A new precise, selective and reliable reversed phase high performance liquid chromatographic (RP-HPLC) method has been developed and validated for the determination of Methyl paraben sodium (MPS) and Propyl paraben sodium (PPS) (preservatives) in Iron protein succinylate syrup. Optimized conditions were; Methanol: Water (65: 35) as mobile phase, UV/Vis detector at the wavelength of 254 nm and flow rate was set at 1.3 ml min−1. By applying the set of conditions, separation of components was carried out in less than 7 min for both the analytes. The method was validated according to International conference of Harmonization (ICH) guidelines and the analytical characteristic parameters of validation included specificity, limit of detection (LOD), limit of quantification, linearity, accuracy, precision and robustness were evaluated. The calibration curve was found to be linear in the range of 0.045 mg mL−1 to 0.075 mg mL−1 for Methyl paraben sodium and 0.015 mg mL−1 to 0.025 mg mL−1 for propyl paraben sodium with a correlation coefficient r2 > 0.999. Accuracy; reported as percentage recovery was found to be in the range of 98.71%–101.64% for Methyl paraben sodium and 99.85%–101.47% for Propyl paraben sodium at 80%, 100% and 120% concentration for both the analytes. The proposed method was found to be precise and robust when evaluated by variations in wavelength, mobile phase composition, temperature and analyst. The limit of detection (LOD) was found 0.001 mg mL−1 (3 ppm) for Methyl paraben sodium and 0.001 mg mL−1 (1 ppm) for Propyl paraben sodium.\",\"PeriodicalId\":7130,\"journal\":{\"name\":\"Acta Chromatographica\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2023-01-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Chromatographica\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1556/1326.2022.00990\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Chromatographica","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1556/1326.2022.00990","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
Development and validation of RP HPLC method for the estimation of methyl paraben sodium and propyl paraben sodium in iron protein succinylate syrup
A new precise, selective and reliable reversed phase high performance liquid chromatographic (RP-HPLC) method has been developed and validated for the determination of Methyl paraben sodium (MPS) and Propyl paraben sodium (PPS) (preservatives) in Iron protein succinylate syrup. Optimized conditions were; Methanol: Water (65: 35) as mobile phase, UV/Vis detector at the wavelength of 254 nm and flow rate was set at 1.3 ml min−1. By applying the set of conditions, separation of components was carried out in less than 7 min for both the analytes. The method was validated according to International conference of Harmonization (ICH) guidelines and the analytical characteristic parameters of validation included specificity, limit of detection (LOD), limit of quantification, linearity, accuracy, precision and robustness were evaluated. The calibration curve was found to be linear in the range of 0.045 mg mL−1 to 0.075 mg mL−1 for Methyl paraben sodium and 0.015 mg mL−1 to 0.025 mg mL−1 for propyl paraben sodium with a correlation coefficient r2 > 0.999. Accuracy; reported as percentage recovery was found to be in the range of 98.71%–101.64% for Methyl paraben sodium and 99.85%–101.47% for Propyl paraben sodium at 80%, 100% and 120% concentration for both the analytes. The proposed method was found to be precise and robust when evaluated by variations in wavelength, mobile phase composition, temperature and analyst. The limit of detection (LOD) was found 0.001 mg mL−1 (3 ppm) for Methyl paraben sodium and 0.001 mg mL−1 (1 ppm) for Propyl paraben sodium.
期刊介绍:
Acta Chromatographica
Open Access
Acta Chromatographica publishes peer-reviewed scientific articles on every field of chromatography, including theory of chromatography; progress in synthesis and characterization of new stationary phases; chromatography of organic, inorganic and complex compounds; enantioseparation and chromatography of chiral compounds; applications of chromatography in biology, pharmacy, medicine, and food analysis; environmental applications of chromatography; analytical and physico-chemical aspects of sample preparation for chromatography; hyphenated and combined techniques; chemometrics and its applications in separation science.