{"title":"轨道减振器的功能和性能测试","authors":"T. Mazilu, I. Răcănel, George Stoicescu","doi":"10.2478/rjti-2018-0010","DOIUrl":null,"url":null,"abstract":"Abstract The rail dampers are mechanical devices which work as dynamic absorbers to reduce the rail vibration and rolling noise. The paper shows the experimental results from the functionality and performance testing of an experimental demonstrative rail damper. The vibration attenuation takes the highest values, namely 6-22 dB, between 160 and 1000 Hz.","PeriodicalId":40630,"journal":{"name":"Romanian Journal of Transport Infrastructure","volume":"7 1","pages":"31 - 39"},"PeriodicalIF":0.1000,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Testing the Functionality and Performance of a Rail Damper\",\"authors\":\"T. Mazilu, I. Răcănel, George Stoicescu\",\"doi\":\"10.2478/rjti-2018-0010\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract The rail dampers are mechanical devices which work as dynamic absorbers to reduce the rail vibration and rolling noise. The paper shows the experimental results from the functionality and performance testing of an experimental demonstrative rail damper. The vibration attenuation takes the highest values, namely 6-22 dB, between 160 and 1000 Hz.\",\"PeriodicalId\":40630,\"journal\":{\"name\":\"Romanian Journal of Transport Infrastructure\",\"volume\":\"7 1\",\"pages\":\"31 - 39\"},\"PeriodicalIF\":0.1000,\"publicationDate\":\"2018-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Romanian Journal of Transport Infrastructure\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2478/rjti-2018-0010\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, CIVIL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Romanian Journal of Transport Infrastructure","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/rjti-2018-0010","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
Testing the Functionality and Performance of a Rail Damper
Abstract The rail dampers are mechanical devices which work as dynamic absorbers to reduce the rail vibration and rolling noise. The paper shows the experimental results from the functionality and performance testing of an experimental demonstrative rail damper. The vibration attenuation takes the highest values, namely 6-22 dB, between 160 and 1000 Hz.