{"title":"基于Bat算法和深度神经网络的肌病和肌萎缩侧索硬化症肌电图分类","authors":"A Bakiya, A Anitha, T Sridevi, K Kamalanand","doi":"10.1155/2022/3517872","DOIUrl":null,"url":null,"abstract":"<p><p>Electromyograms (EMG) are a recorded galvanic action of nerves and muscles which assists in diagnosing the disorders associated with muscles and nerves. The efficient discrimination of abnormal EMG signals, myopathy and amyotrophic lateral sclerosis, engage crucial role in automatic diagnostic assistance tools, since EMG signals are nonstationary signals. Hence, for computer-aided identification of abnormalities, extraction of features, selection of superlative feature subset, and developing an efficient classifier are indispensable. Initially, time domain and Wigner-Ville transformed time-frequency features were extracted from abnormal EMG signals for experiments. The selection of substantial characteristics from time and time-frequency features was performed using bat algorithm. Extensively, deep neural network classifier is modelled for selected feature subset using bat algorithm from extracted time and time-frequency features. The performance of deep neural network exerting selected features from bat algorithm was compared with conventional artificial neural network. Results demonstrate that the deep neural network modelled with layers 2 and 3 (neurons = 2 and 4) using time domain features is efficient in classifying the abnormalities of EMG signals with an accuracy, sensitivity, and specificity of 100% and also exhibited finer performance. Correspondingly, the developed conventional single layer artificial neural network (neurons = 7) with time domain features has shown an accuracy of 83.3%, sensitivity of 100%, and specificity of 71.42%. The work materializes the significance of conventional and deep neural network using time and time-frequency features in diagnosing the abnormal signals exists in neuromuscular system using efficient classification.</p>","PeriodicalId":50733,"journal":{"name":"Behavioural Neurology","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2022-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9001138/pdf/","citationCount":"4","resultStr":"{\"title\":\"Classification of Myopathy and Amyotrophic Lateral Sclerosis Electromyograms Using Bat Algorithm and Deep Neural Networks.\",\"authors\":\"A Bakiya, A Anitha, T Sridevi, K Kamalanand\",\"doi\":\"10.1155/2022/3517872\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Electromyograms (EMG) are a recorded galvanic action of nerves and muscles which assists in diagnosing the disorders associated with muscles and nerves. The efficient discrimination of abnormal EMG signals, myopathy and amyotrophic lateral sclerosis, engage crucial role in automatic diagnostic assistance tools, since EMG signals are nonstationary signals. Hence, for computer-aided identification of abnormalities, extraction of features, selection of superlative feature subset, and developing an efficient classifier are indispensable. Initially, time domain and Wigner-Ville transformed time-frequency features were extracted from abnormal EMG signals for experiments. The selection of substantial characteristics from time and time-frequency features was performed using bat algorithm. Extensively, deep neural network classifier is modelled for selected feature subset using bat algorithm from extracted time and time-frequency features. The performance of deep neural network exerting selected features from bat algorithm was compared with conventional artificial neural network. Results demonstrate that the deep neural network modelled with layers 2 and 3 (neurons = 2 and 4) using time domain features is efficient in classifying the abnormalities of EMG signals with an accuracy, sensitivity, and specificity of 100% and also exhibited finer performance. Correspondingly, the developed conventional single layer artificial neural network (neurons = 7) with time domain features has shown an accuracy of 83.3%, sensitivity of 100%, and specificity of 71.42%. The work materializes the significance of conventional and deep neural network using time and time-frequency features in diagnosing the abnormal signals exists in neuromuscular system using efficient classification.</p>\",\"PeriodicalId\":50733,\"journal\":{\"name\":\"Behavioural Neurology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2022-04-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9001138/pdf/\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Behavioural Neurology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1155/2022/3517872\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Behavioural Neurology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1155/2022/3517872","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
Classification of Myopathy and Amyotrophic Lateral Sclerosis Electromyograms Using Bat Algorithm and Deep Neural Networks.
Electromyograms (EMG) are a recorded galvanic action of nerves and muscles which assists in diagnosing the disorders associated with muscles and nerves. The efficient discrimination of abnormal EMG signals, myopathy and amyotrophic lateral sclerosis, engage crucial role in automatic diagnostic assistance tools, since EMG signals are nonstationary signals. Hence, for computer-aided identification of abnormalities, extraction of features, selection of superlative feature subset, and developing an efficient classifier are indispensable. Initially, time domain and Wigner-Ville transformed time-frequency features were extracted from abnormal EMG signals for experiments. The selection of substantial characteristics from time and time-frequency features was performed using bat algorithm. Extensively, deep neural network classifier is modelled for selected feature subset using bat algorithm from extracted time and time-frequency features. The performance of deep neural network exerting selected features from bat algorithm was compared with conventional artificial neural network. Results demonstrate that the deep neural network modelled with layers 2 and 3 (neurons = 2 and 4) using time domain features is efficient in classifying the abnormalities of EMG signals with an accuracy, sensitivity, and specificity of 100% and also exhibited finer performance. Correspondingly, the developed conventional single layer artificial neural network (neurons = 7) with time domain features has shown an accuracy of 83.3%, sensitivity of 100%, and specificity of 71.42%. The work materializes the significance of conventional and deep neural network using time and time-frequency features in diagnosing the abnormal signals exists in neuromuscular system using efficient classification.
期刊介绍:
Behavioural Neurology is a peer-reviewed, Open Access journal which publishes original research articles, review articles and clinical studies based on various diseases and syndromes in behavioural neurology. The aim of the journal is to provide a platform for researchers and clinicians working in various fields of neurology including cognitive neuroscience, neuropsychology and neuropsychiatry.
Topics of interest include:
ADHD
Aphasia
Autism
Alzheimer’s Disease
Behavioural Disorders
Dementia
Epilepsy
Multiple Sclerosis
Parkinson’s Disease
Psychosis
Stroke
Traumatic brain injury.