ISO 15189:2012认证细胞病理学实验室的分析和后分析阶段——五年机构经验

IF 1 4区 医学 Q4 MEDICAL LABORATORY TECHNOLOGY
Journal of Cytology Pub Date : 2022-01-01 Epub Date: 2022-02-03 DOI:10.4103/JOC.JOC_90_20
Smita Chandra, Anuradha Kusum, Dushyant Singh Gaur, Harish Chandra
{"title":"ISO 15189:2012认证细胞病理学实验室的分析和后分析阶段——五年机构经验","authors":"Smita Chandra, Anuradha Kusum, Dushyant Singh Gaur, Harish Chandra","doi":"10.4103/JOC.JOC_90_20","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Analytical and post analytical phase are integral part of total quality management system and include steps from submission of slides till reports are dispatched. The present study was conducted to analyze the analytical and post analytical phase of the ISO15189:2012 certified cytopathology laboratory. It was also intended to study the various errors which were encountered and steps taken to reduce these discrepancies.</p><p><strong>Methods: </strong>The study included all documents of quality program from 1 November 2014 till 31 Oct 2019 in medical institute situated in north Himalayan region of India. All the data was recorded and analyzed for analytical and post analytical phase.</p><p><strong>Results: </strong>The number of samples received in cytopathology lab was 21,566 with total quality errors of 5.19%. Out of these pre-analytical errors were 55%, analytical 10.5% and post analytical errors constituted 34.4%. The maximum errors detected were due to typographical errors followed by delayed turnaround time. Cyto-histopathological discordance was 10.5% in non-gynecological cases and 2.2% in gynecological cases.</p><p><strong>Conclusion: </strong>Analytical and post analytical phase analysis is essential to minimize the errors and improve the quality of cytopathology lab. Cyto-histopathological correlation is valuable for continuous data tracking in the cytopathology with analytical errors analysis. Maintenance of external, internal quality program, turnaround time with documentation, continuous training and communication with clinician is fundamental for quality improvement in any cytopathology lab. Acknowledgement of nonconformance with root cause analysis and sincere efforts to minimize them is the basic key for successful quality management.</p>","PeriodicalId":50217,"journal":{"name":"Journal of Cytology","volume":"39 1","pages":"37-43"},"PeriodicalIF":1.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8955700/pdf/","citationCount":"0","resultStr":"{\"title\":\"Analytical and Post Analytical Phase of an ISO 15189:2012 Certified Cytopathology Laboratory-A Five Year Institutional Experience.\",\"authors\":\"Smita Chandra, Anuradha Kusum, Dushyant Singh Gaur, Harish Chandra\",\"doi\":\"10.4103/JOC.JOC_90_20\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>Analytical and post analytical phase are integral part of total quality management system and include steps from submission of slides till reports are dispatched. The present study was conducted to analyze the analytical and post analytical phase of the ISO15189:2012 certified cytopathology laboratory. It was also intended to study the various errors which were encountered and steps taken to reduce these discrepancies.</p><p><strong>Methods: </strong>The study included all documents of quality program from 1 November 2014 till 31 Oct 2019 in medical institute situated in north Himalayan region of India. All the data was recorded and analyzed for analytical and post analytical phase.</p><p><strong>Results: </strong>The number of samples received in cytopathology lab was 21,566 with total quality errors of 5.19%. Out of these pre-analytical errors were 55%, analytical 10.5% and post analytical errors constituted 34.4%. The maximum errors detected were due to typographical errors followed by delayed turnaround time. Cyto-histopathological discordance was 10.5% in non-gynecological cases and 2.2% in gynecological cases.</p><p><strong>Conclusion: </strong>Analytical and post analytical phase analysis is essential to minimize the errors and improve the quality of cytopathology lab. Cyto-histopathological correlation is valuable for continuous data tracking in the cytopathology with analytical errors analysis. Maintenance of external, internal quality program, turnaround time with documentation, continuous training and communication with clinician is fundamental for quality improvement in any cytopathology lab. Acknowledgement of nonconformance with root cause analysis and sincere efforts to minimize them is the basic key for successful quality management.</p>\",\"PeriodicalId\":50217,\"journal\":{\"name\":\"Journal of Cytology\",\"volume\":\"39 1\",\"pages\":\"37-43\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8955700/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Cytology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4103/JOC.JOC_90_20\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/2/3 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cytology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4103/JOC.JOC_90_20","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/2/3 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目标:分析和分析后阶段是全面质量管理体系的组成部分,包括从提交幻灯片到发送报告的各个步骤。本研究旨在分析ISO15189:2012认证的细胞病理学实验室的分析和分析后阶段。它还打算研究所遇到的各种错误以及为减少这些差异而采取的步骤。方法:本研究包括2014年11月1日至2019年10月31日在印度喜马拉雅山脉北部医学院进行的所有质量计划文件。在分析和分析后阶段,对所有数据进行了记录和分析。结果:细胞病理学实验室收到的样本数量为21566个,总质量误差为5.19%。其中分析前误差为55%,分析后误差为10.5%,分析后的误差为34.4%。检测到的最大误差是由于印刷错误和周转时间延迟。非妇科病例的细胞组织病理学不一致率为10.5%,妇科病例为2.2%。结论:分析和分析后阶段分析对于最大限度地减少误差和提高细胞病理学实验室的质量至关重要。细胞-组织病理学相关性对于分析误差分析的细胞病理学中的连续数据跟踪是有价值的。维护外部和内部质量计划、文件的周转时间、持续培训以及与临床医生的沟通是任何细胞病理学实验室质量改进的基础。确认不符合根本原因分析并真诚努力将其降至最低是成功质量管理的基本关键。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Analytical and Post Analytical Phase of an ISO 15189:2012 Certified Cytopathology Laboratory-A Five Year Institutional Experience.

Objective: Analytical and post analytical phase are integral part of total quality management system and include steps from submission of slides till reports are dispatched. The present study was conducted to analyze the analytical and post analytical phase of the ISO15189:2012 certified cytopathology laboratory. It was also intended to study the various errors which were encountered and steps taken to reduce these discrepancies.

Methods: The study included all documents of quality program from 1 November 2014 till 31 Oct 2019 in medical institute situated in north Himalayan region of India. All the data was recorded and analyzed for analytical and post analytical phase.

Results: The number of samples received in cytopathology lab was 21,566 with total quality errors of 5.19%. Out of these pre-analytical errors were 55%, analytical 10.5% and post analytical errors constituted 34.4%. The maximum errors detected were due to typographical errors followed by delayed turnaround time. Cyto-histopathological discordance was 10.5% in non-gynecological cases and 2.2% in gynecological cases.

Conclusion: Analytical and post analytical phase analysis is essential to minimize the errors and improve the quality of cytopathology lab. Cyto-histopathological correlation is valuable for continuous data tracking in the cytopathology with analytical errors analysis. Maintenance of external, internal quality program, turnaround time with documentation, continuous training and communication with clinician is fundamental for quality improvement in any cytopathology lab. Acknowledgement of nonconformance with root cause analysis and sincere efforts to minimize them is the basic key for successful quality management.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Cytology
Journal of Cytology MEDICAL LABORATORY TECHNOLOGY-
CiteScore
1.80
自引率
7.70%
发文量
34
审稿时长
46 weeks
期刊介绍: The Journal of Cytology is the official Quarterly publication of the Indian Academy of Cytologists. It is in the 25th year of publication in the year 2008. The journal covers all aspects of diagnostic cytology, including fine needle aspiration cytology, gynecological and non-gynecological cytology. Articles on ancillary techniques, like cytochemistry, immunocytochemistry, electron microscopy, molecular cytopathology, as applied to cytological material are also welcome. The journal gives preference to clinically oriented studies over experimental and animal studies. The Journal would publish peer-reviewed original research papers, case reports, systematic reviews, meta-analysis, and debates.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信