M. Mordmüller, V. Kleyman, M. Schaller, M. Wilson, D. Theisen-Kunde, K. Worthmann, M. Müller, R. Brinkmann
{"title":"使用10kHz重复频率的单个激光进行温控视网膜激光治疗","authors":"M. Mordmüller, V. Kleyman, M. Schaller, M. Wilson, D. Theisen-Kunde, K. Worthmann, M. Müller, R. Brinkmann","doi":"10.1515/aot-2021-0041","DOIUrl":null,"url":null,"abstract":"Abstract Laser photocoagulation is one of the most frequently used treatment approaches in ophthalmology for a variety of retinal diseases. Depending on indication, treatment intensity varies from application of specific micro injuries down to gentle temperature increases without inducing cell damage. Especially for the latter, proper energy dosing is still a challenging issue, which mostly relies on the physician’s experience. Pulsed laser photoacoustic temperature measurement has already proven its ability for automated irradiation control during laser treatment but suffers from a comparatively high instrumental effort due to combination with a conventional continuous wave treatment laser. In this paper, a simplified setup with a single pulsed laser at 10 kHz repetition rate is presented. The setup combines the instrumentation for treatment as well as temperature measurement and control in a single device. In order to compare the solely pulsed heating with continuous wave (cw) tissue heating, pulse energies of 4 µJ were applied with a repetition rate of 1 kHz to probe the temperature rise, respectively. With the same average laser power of 60 mW an almost identical temporal temperature course was retrieved in both irradiation modes as expected. The ability to reach and maintain a chosen aim temperature of 41 °C is demonstrated by means of model predictive control (MPC) and extended Kalman filtering at a the measurement rate of 250 Hz with an accuracy of less than ±0.1 °C. A major advantage of optimization-based control techniques like MPC is their capability of rigorously ensuring constraints, e.g., temperature limits, and thus, realizing a more reliable and secure temperature control during retinal laser irradiation.","PeriodicalId":46010,"journal":{"name":"Advanced Optical Technologies","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2021-11-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Towards temperature controlled retinal laser treatment with a single laser at 10 kHz repetition rate\",\"authors\":\"M. Mordmüller, V. Kleyman, M. Schaller, M. Wilson, D. Theisen-Kunde, K. Worthmann, M. Müller, R. Brinkmann\",\"doi\":\"10.1515/aot-2021-0041\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Laser photocoagulation is one of the most frequently used treatment approaches in ophthalmology for a variety of retinal diseases. Depending on indication, treatment intensity varies from application of specific micro injuries down to gentle temperature increases without inducing cell damage. Especially for the latter, proper energy dosing is still a challenging issue, which mostly relies on the physician’s experience. Pulsed laser photoacoustic temperature measurement has already proven its ability for automated irradiation control during laser treatment but suffers from a comparatively high instrumental effort due to combination with a conventional continuous wave treatment laser. In this paper, a simplified setup with a single pulsed laser at 10 kHz repetition rate is presented. The setup combines the instrumentation for treatment as well as temperature measurement and control in a single device. In order to compare the solely pulsed heating with continuous wave (cw) tissue heating, pulse energies of 4 µJ were applied with a repetition rate of 1 kHz to probe the temperature rise, respectively. With the same average laser power of 60 mW an almost identical temporal temperature course was retrieved in both irradiation modes as expected. The ability to reach and maintain a chosen aim temperature of 41 °C is demonstrated by means of model predictive control (MPC) and extended Kalman filtering at a the measurement rate of 250 Hz with an accuracy of less than ±0.1 °C. A major advantage of optimization-based control techniques like MPC is their capability of rigorously ensuring constraints, e.g., temperature limits, and thus, realizing a more reliable and secure temperature control during retinal laser irradiation.\",\"PeriodicalId\":46010,\"journal\":{\"name\":\"Advanced Optical Technologies\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2021-11-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advanced Optical Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1515/aot-2021-0041\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"OPTICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advanced Optical Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/aot-2021-0041","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPTICS","Score":null,"Total":0}
Towards temperature controlled retinal laser treatment with a single laser at 10 kHz repetition rate
Abstract Laser photocoagulation is one of the most frequently used treatment approaches in ophthalmology for a variety of retinal diseases. Depending on indication, treatment intensity varies from application of specific micro injuries down to gentle temperature increases without inducing cell damage. Especially for the latter, proper energy dosing is still a challenging issue, which mostly relies on the physician’s experience. Pulsed laser photoacoustic temperature measurement has already proven its ability for automated irradiation control during laser treatment but suffers from a comparatively high instrumental effort due to combination with a conventional continuous wave treatment laser. In this paper, a simplified setup with a single pulsed laser at 10 kHz repetition rate is presented. The setup combines the instrumentation for treatment as well as temperature measurement and control in a single device. In order to compare the solely pulsed heating with continuous wave (cw) tissue heating, pulse energies of 4 µJ were applied with a repetition rate of 1 kHz to probe the temperature rise, respectively. With the same average laser power of 60 mW an almost identical temporal temperature course was retrieved in both irradiation modes as expected. The ability to reach and maintain a chosen aim temperature of 41 °C is demonstrated by means of model predictive control (MPC) and extended Kalman filtering at a the measurement rate of 250 Hz with an accuracy of less than ±0.1 °C. A major advantage of optimization-based control techniques like MPC is their capability of rigorously ensuring constraints, e.g., temperature limits, and thus, realizing a more reliable and secure temperature control during retinal laser irradiation.
期刊介绍:
Advanced Optical Technologies is a strictly peer-reviewed scientific journal. The major aim of Advanced Optical Technologies is to publish recent progress in the fields of optical design, optical engineering, and optical manufacturing. Advanced Optical Technologies has a main focus on applied research and addresses scientists as well as experts in industrial research and development. Advanced Optical Technologies partners with the European Optical Society (EOS). All its 4.500+ members have free online access to the journal through their EOS member account. Topics: Optical design, Lithography, Opto-mechanical engineering, Illumination and lighting technology, Precision fabrication, Image sensor devices, Optical materials (polymer based, inorganic, crystalline/amorphous), Optical instruments in life science (biology, medicine, laboratories), Optical metrology, Optics in aerospace/defense, Simulation, interdisciplinary, Optics for astronomy, Standards, Consumer optics, Optical coatings.