碳离子治疗中克隆生存的RBE计算:光子剂量-响应曲线中α和β绝对值的重要性以及减轻它们的反相关性的策略

IF 1.3 Q3 INSTRUMENTS & INSTRUMENTATION
A. Parisi, C. Beltran, K. Furutani
{"title":"碳离子治疗中克隆生存的RBE计算:光子剂量-响应曲线中α和β绝对值的重要性以及减轻它们的反相关性的策略","authors":"A. Parisi, C. Beltran, K. Furutani","doi":"10.3390/qubs7010003","DOIUrl":null,"url":null,"abstract":"The computation of the relative biological effectiveness (RBE) is a fundamental step in the planning of cancer radiotherapy treatments with accelerated ions. Numerical parameters derived analyzing the dose response of the chosen cell line after irradiation to photons (i.e., α and β, namely the linear and quadratic terms of the linear-quadratic model of cell survival) are generally used as input to biophysical models to predict the ion RBE. The α/β ratio for the photon exposure is generally regarded as an indicator of cell radiosensitivity. However, previous studies suggest that α/β might not be a sufficient parameter to model the RBE of relatively high linear energy transfer (LET) radiation such as carbon ions. For a fixed α/β, the effect of the absolute values of α and β on the computed RBE is underexplored. Furthermore, since α and β are anticorrelated during the fit of the photon-exposed in vitro survival data, different linear-quadratic fits could produce different sets of α and β, thus affecting the RBE calculations. This article reports the combined effect of the α/β ratio and the absolute values α and β on the RBE computed with the Mayo Clinic Florida microdosimetric kinetic model (MCF MKM) for 12C ions of different LET. Furthermore, we introduce a theory-based strategy to potentially mitigate the anticorrelation between α and β during the fit of the photon dose-response biological data.","PeriodicalId":31879,"journal":{"name":"Quantum Beam Science","volume":" ","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2023-01-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Clonogenic Survival RBE Calculations in Carbon Ion Therapy: The Importance of the Absolute Values of α and β in the Photon Dose-Response Curve and a Strategy to Mitigate Their Anticorrelation\",\"authors\":\"A. Parisi, C. Beltran, K. Furutani\",\"doi\":\"10.3390/qubs7010003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The computation of the relative biological effectiveness (RBE) is a fundamental step in the planning of cancer radiotherapy treatments with accelerated ions. Numerical parameters derived analyzing the dose response of the chosen cell line after irradiation to photons (i.e., α and β, namely the linear and quadratic terms of the linear-quadratic model of cell survival) are generally used as input to biophysical models to predict the ion RBE. The α/β ratio for the photon exposure is generally regarded as an indicator of cell radiosensitivity. However, previous studies suggest that α/β might not be a sufficient parameter to model the RBE of relatively high linear energy transfer (LET) radiation such as carbon ions. For a fixed α/β, the effect of the absolute values of α and β on the computed RBE is underexplored. Furthermore, since α and β are anticorrelated during the fit of the photon-exposed in vitro survival data, different linear-quadratic fits could produce different sets of α and β, thus affecting the RBE calculations. This article reports the combined effect of the α/β ratio and the absolute values α and β on the RBE computed with the Mayo Clinic Florida microdosimetric kinetic model (MCF MKM) for 12C ions of different LET. Furthermore, we introduce a theory-based strategy to potentially mitigate the anticorrelation between α and β during the fit of the photon dose-response biological data.\",\"PeriodicalId\":31879,\"journal\":{\"name\":\"Quantum Beam Science\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2023-01-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Quantum Beam Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/qubs7010003\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Quantum Beam Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/qubs7010003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 1

摘要

相对生物有效性(RBE)的计算是癌症加速离子放射治疗计划的基本步骤。分析所选细胞系在照射光子后的剂量响应的数值参数(即α和β,即细胞存活的线性二次模型的线性项和二次项)通常用作生物物理模型的输入,以预测离子RBE。光子暴露的α/β比值通常被认为是细胞放射敏感性的指标。然而,先前的研究表明,α/β可能不是一个足够的参数来模拟相对较高的线性能量转移(LET)辐射(如碳离子)的RBE。对于固定的α/β,α和β的绝对值对计算的RBE的影响尚未得到充分探讨。此外,由于在光子体外存活数据的拟合过程中,α和β是反相关的,不同的线性二次拟合可能会产生不同的α和β集,从而影响RBE计算。本文报道了α/β比值和绝对值α和β对用Mayo Clinic Florida微剂量动力学模型(MCF-MKM)计算的不同LET的12C离子的RBE的综合影响。此外,我们引入了一种基于理论的策略,以在光子剂量反应生物学数据的拟合过程中潜在地减轻α和β之间的反相关性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Clonogenic Survival RBE Calculations in Carbon Ion Therapy: The Importance of the Absolute Values of α and β in the Photon Dose-Response Curve and a Strategy to Mitigate Their Anticorrelation
The computation of the relative biological effectiveness (RBE) is a fundamental step in the planning of cancer radiotherapy treatments with accelerated ions. Numerical parameters derived analyzing the dose response of the chosen cell line after irradiation to photons (i.e., α and β, namely the linear and quadratic terms of the linear-quadratic model of cell survival) are generally used as input to biophysical models to predict the ion RBE. The α/β ratio for the photon exposure is generally regarded as an indicator of cell radiosensitivity. However, previous studies suggest that α/β might not be a sufficient parameter to model the RBE of relatively high linear energy transfer (LET) radiation such as carbon ions. For a fixed α/β, the effect of the absolute values of α and β on the computed RBE is underexplored. Furthermore, since α and β are anticorrelated during the fit of the photon-exposed in vitro survival data, different linear-quadratic fits could produce different sets of α and β, thus affecting the RBE calculations. This article reports the combined effect of the α/β ratio and the absolute values α and β on the RBE computed with the Mayo Clinic Florida microdosimetric kinetic model (MCF MKM) for 12C ions of different LET. Furthermore, we introduce a theory-based strategy to potentially mitigate the anticorrelation between α and β during the fit of the photon dose-response biological data.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.80
自引率
28.60%
发文量
27
审稿时长
11 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信