{"title":"精加工工艺对高半透明4Y-PSZ、5Y-PSZ和6Y-PSZ单片氧化锆表面粗糙度和双轴抗折强度的影响","authors":"Gülsüm Doğru, Elif Demiralp, Emre Koçak, H. H. Örkcü, Prof. Dr. Cemal Aydin, H. Yılmaz","doi":"10.33808/clinexphealthsci.1073010","DOIUrl":null,"url":null,"abstract":"Objective: This study aims to investigate the effects of glazing, polishing and polishing with a polishing paste of newly developed highly translucent materials on the flexural strength of these materials and aims to illuminate where there is not much study yet on the finishing procedures to be done. \nMethods: Three different high translucency Y-PSZ (Yittria partially stabilized zirconia): KST (Katana STML), KUT (Katana UTML), NCQ (Nacera Pearl Q3 Multi-Shade) and one translucent 3Y-TZP (3-yttria stabilized tetragonal zirconia polycrystalline): NCMS (Nacera Pearl Multi-Shade) zirconia system were used. A total of 120 specimens were prepared in the form of discs with a diameter of 14 mm and dimensions of 1.2 ± 0.2 \nmm. Three experimental groups (n = 30) were formed from each type of material, using three finishing protocols: Diamond Polishing system (DP); Diamond Polishing system followed by Polishing Paste (PP); Glaze Application (GP). Surface Roughness (Ra) was measured by using a contact profilometer, and a biaxial flexural strength test was applied to determine their flexural strength. The obtained data were analyzed using the Weibull distribution. All results were evaluated statistically. \nResults: For Ra values, there was a statistical difference between all the procedures applied in the KST material as in the NCQ material. However, there was no statistical difference between GP and PP procedures in Ra values in the NCMS material and between DP and PP procedures in the KUT material. The characteristic strengths of DP applied to NCMS and NCQ material, PP applied to KST, and KUT material had the highest value. The highest m values for DP were determined in KST, NCMS, NCQ materials, while in KUT material, PP was determined in the finishing procedure. \nConclusion: Finishing procedures have significant effects on surface roughness and flexural strength values for translucent zirconia materials. The lowest Ra value and the highest flexural strength were found in the DP group of NCMS. In KST and KUT materials, the highest flexural strength results were found in the PP procedure while NCQ was not affected by finishing procedures.","PeriodicalId":10192,"journal":{"name":"Clinical and Experimental Health Sciences","volume":" ","pages":""},"PeriodicalIF":0.3000,"publicationDate":"2022-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Influence of Finishing Procedures on Surface Roughness and Biaxial Flexural Strength of High-translucent 4Y-PSZ, 5Y-PSZ, and 6Y-PSZ Monolithic Zirconia\",\"authors\":\"Gülsüm Doğru, Elif Demiralp, Emre Koçak, H. H. Örkcü, Prof. Dr. Cemal Aydin, H. Yılmaz\",\"doi\":\"10.33808/clinexphealthsci.1073010\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective: This study aims to investigate the effects of glazing, polishing and polishing with a polishing paste of newly developed highly translucent materials on the flexural strength of these materials and aims to illuminate where there is not much study yet on the finishing procedures to be done. \\nMethods: Three different high translucency Y-PSZ (Yittria partially stabilized zirconia): KST (Katana STML), KUT (Katana UTML), NCQ (Nacera Pearl Q3 Multi-Shade) and one translucent 3Y-TZP (3-yttria stabilized tetragonal zirconia polycrystalline): NCMS (Nacera Pearl Multi-Shade) zirconia system were used. A total of 120 specimens were prepared in the form of discs with a diameter of 14 mm and dimensions of 1.2 ± 0.2 \\nmm. Three experimental groups (n = 30) were formed from each type of material, using three finishing protocols: Diamond Polishing system (DP); Diamond Polishing system followed by Polishing Paste (PP); Glaze Application (GP). Surface Roughness (Ra) was measured by using a contact profilometer, and a biaxial flexural strength test was applied to determine their flexural strength. The obtained data were analyzed using the Weibull distribution. All results were evaluated statistically. \\nResults: For Ra values, there was a statistical difference between all the procedures applied in the KST material as in the NCQ material. However, there was no statistical difference between GP and PP procedures in Ra values in the NCMS material and between DP and PP procedures in the KUT material. The characteristic strengths of DP applied to NCMS and NCQ material, PP applied to KST, and KUT material had the highest value. The highest m values for DP were determined in KST, NCMS, NCQ materials, while in KUT material, PP was determined in the finishing procedure. \\nConclusion: Finishing procedures have significant effects on surface roughness and flexural strength values for translucent zirconia materials. The lowest Ra value and the highest flexural strength were found in the DP group of NCMS. In KST and KUT materials, the highest flexural strength results were found in the PP procedure while NCQ was not affected by finishing procedures.\",\"PeriodicalId\":10192,\"journal\":{\"name\":\"Clinical and Experimental Health Sciences\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.3000,\"publicationDate\":\"2022-11-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical and Experimental Health Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.33808/clinexphealthsci.1073010\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"MEDICINE, RESEARCH & EXPERIMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical and Experimental Health Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33808/clinexphealthsci.1073010","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0
摘要
目的:本研究旨在研究新开发的高度半透明材料的上光、抛光和抛光膏对这些材料抗弯强度的影响,并旨在阐明在整理过程中尚未进行太多研究的地方。方法:采用三种不同的高半透明Y-PSZ(氧化钇部分稳定氧化锆):KST (Katana STML)、KUT (Katana UTML)、NCQ (Nacera Pearl Q3 Multi-Shade)和一种半透明3Y-TZP(3-氧化钇稳定四方氧化锆多晶):NCMS (Nacera Pearl Multi-Shade)氧化锆体系。共制作120个标本,直径为14mm,尺寸为1.2±0.2 mm。每种材料组成三个实验组(n = 30),采用三种抛光方案:金刚石抛光系统(DP);采用抛光膏(PP)的金刚石抛光系统;上釉(GP)。使用接触轮廓仪测量表面粗糙度(Ra),并进行双轴抗弯强度试验以确定其抗弯强度。所得数据采用威布尔分布进行分析。所有结果均进行统计学评价。结果:对于Ra值,在KST材料和NCQ材料中应用的所有程序之间存在统计学差异。然而,在NCMS材料中,GP和PP处理的Ra值与KUT材料中DP和PP处理的Ra值没有统计学差异。应用于NCMS和NCQ材料的DP、应用于KST和KUT材料的PP的特征强度最高。在KST、NCMS、NCQ材料中,DP的m值最高,而在KUT材料中,PP的m值在加工过程中最高。结论:处理工艺对半透明氧化锆材料的表面粗糙度和抗弯强度有显著影响。DP组Ra值最低,抗折强度最高。在KST和KUT材料中,PP工艺的抗弯强度结果最高,而NCQ不受加工工艺的影响。
Influence of Finishing Procedures on Surface Roughness and Biaxial Flexural Strength of High-translucent 4Y-PSZ, 5Y-PSZ, and 6Y-PSZ Monolithic Zirconia
Objective: This study aims to investigate the effects of glazing, polishing and polishing with a polishing paste of newly developed highly translucent materials on the flexural strength of these materials and aims to illuminate where there is not much study yet on the finishing procedures to be done.
Methods: Three different high translucency Y-PSZ (Yittria partially stabilized zirconia): KST (Katana STML), KUT (Katana UTML), NCQ (Nacera Pearl Q3 Multi-Shade) and one translucent 3Y-TZP (3-yttria stabilized tetragonal zirconia polycrystalline): NCMS (Nacera Pearl Multi-Shade) zirconia system were used. A total of 120 specimens were prepared in the form of discs with a diameter of 14 mm and dimensions of 1.2 ± 0.2
mm. Three experimental groups (n = 30) were formed from each type of material, using three finishing protocols: Diamond Polishing system (DP); Diamond Polishing system followed by Polishing Paste (PP); Glaze Application (GP). Surface Roughness (Ra) was measured by using a contact profilometer, and a biaxial flexural strength test was applied to determine their flexural strength. The obtained data were analyzed using the Weibull distribution. All results were evaluated statistically.
Results: For Ra values, there was a statistical difference between all the procedures applied in the KST material as in the NCQ material. However, there was no statistical difference between GP and PP procedures in Ra values in the NCMS material and between DP and PP procedures in the KUT material. The characteristic strengths of DP applied to NCMS and NCQ material, PP applied to KST, and KUT material had the highest value. The highest m values for DP were determined in KST, NCMS, NCQ materials, while in KUT material, PP was determined in the finishing procedure.
Conclusion: Finishing procedures have significant effects on surface roughness and flexural strength values for translucent zirconia materials. The lowest Ra value and the highest flexural strength were found in the DP group of NCMS. In KST and KUT materials, the highest flexural strength results were found in the PP procedure while NCQ was not affected by finishing procedures.