K. Širůčková, P. Marcon, M. Dostál, A. Sirucková, P. Dohnal
{"title":"双能谱计算机断层扫描:真实和虚拟非对比度增强图像的比较","authors":"K. Širůčková, P. Marcon, M. Dostál, A. Sirucková, P. Dohnal","doi":"10.2478/msr-2022-0033","DOIUrl":null,"url":null,"abstract":"Abstract Spectral computed tomography (CT) imaging is one of several image reconstruction techniques based on the use of dual-layer CT. The intensity and attenuation of the radiation are measured in relation to different wavelengths, and such a procedure results in complex three-dimensional (3D) imaging and (pseudo) color adjustment of the soft tissue. This paper compares true non-contrast (TNC) enhanced images with virtual non-contrast (VNC) enhanced ones. Virtual native images are acquired by means of spectral computed tomography, and it has been suggested that VNCs could potentially substitute real native images to reduce significantly the total radiation dose from multiphase spectral CT. A comparison was performed by defining certain parameters that represent the difference between the measured and the calculated values in the images. The parameters included the mean value and standard deviation of the computed tomography number, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). All of these items were analyzed via statistical tests using p-value. The results are interpreted and correlated with those presented by other authors, who, however, did not make an examination on a comprehensive basis - five tissues simultaneously by using a single device. Prospectively, if analogies were found between the two types of images, it would be possible to skip the TNC image, thus markedly reducing the radiation dose for the patient.","PeriodicalId":49848,"journal":{"name":"Measurement Science Review","volume":"22 1","pages":"261 - 268"},"PeriodicalIF":0.8000,"publicationDate":"2022-10-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Dual-Energy Spectral Computed Tomography: Comparing True and Virtual Non Contrast Enhanced Images\",\"authors\":\"K. Širůčková, P. Marcon, M. Dostál, A. Sirucková, P. Dohnal\",\"doi\":\"10.2478/msr-2022-0033\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Spectral computed tomography (CT) imaging is one of several image reconstruction techniques based on the use of dual-layer CT. The intensity and attenuation of the radiation are measured in relation to different wavelengths, and such a procedure results in complex three-dimensional (3D) imaging and (pseudo) color adjustment of the soft tissue. This paper compares true non-contrast (TNC) enhanced images with virtual non-contrast (VNC) enhanced ones. Virtual native images are acquired by means of spectral computed tomography, and it has been suggested that VNCs could potentially substitute real native images to reduce significantly the total radiation dose from multiphase spectral CT. A comparison was performed by defining certain parameters that represent the difference between the measured and the calculated values in the images. The parameters included the mean value and standard deviation of the computed tomography number, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). All of these items were analyzed via statistical tests using p-value. The results are interpreted and correlated with those presented by other authors, who, however, did not make an examination on a comprehensive basis - five tissues simultaneously by using a single device. Prospectively, if analogies were found between the two types of images, it would be possible to skip the TNC image, thus markedly reducing the radiation dose for the patient.\",\"PeriodicalId\":49848,\"journal\":{\"name\":\"Measurement Science Review\",\"volume\":\"22 1\",\"pages\":\"261 - 268\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2022-10-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Measurement Science Review\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.2478/msr-2022-0033\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Measurement Science Review","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.2478/msr-2022-0033","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
Dual-Energy Spectral Computed Tomography: Comparing True and Virtual Non Contrast Enhanced Images
Abstract Spectral computed tomography (CT) imaging is one of several image reconstruction techniques based on the use of dual-layer CT. The intensity and attenuation of the radiation are measured in relation to different wavelengths, and such a procedure results in complex three-dimensional (3D) imaging and (pseudo) color adjustment of the soft tissue. This paper compares true non-contrast (TNC) enhanced images with virtual non-contrast (VNC) enhanced ones. Virtual native images are acquired by means of spectral computed tomography, and it has been suggested that VNCs could potentially substitute real native images to reduce significantly the total radiation dose from multiphase spectral CT. A comparison was performed by defining certain parameters that represent the difference between the measured and the calculated values in the images. The parameters included the mean value and standard deviation of the computed tomography number, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). All of these items were analyzed via statistical tests using p-value. The results are interpreted and correlated with those presented by other authors, who, however, did not make an examination on a comprehensive basis - five tissues simultaneously by using a single device. Prospectively, if analogies were found between the two types of images, it would be possible to skip the TNC image, thus markedly reducing the radiation dose for the patient.
期刊介绍:
- theory of measurement - mathematical processing of measured data - measurement uncertainty minimisation - statistical methods in data evaluation and modelling - measurement as an interdisciplinary activity - measurement science in education - medical imaging methods, image processing - biosignal measurement, processing and analysis - model based biomeasurements - neural networks in biomeasurement - telemeasurement in biomedicine - measurement in nanomedicine - measurement of basic physical quantities - magnetic and electric fields measurements - measurement of geometrical and mechanical quantities - optical measuring methods - electromagnetic compatibility - measurement in material science