五种不同镍钛旋转锉系统在模拟渠道中成形能力的比较评价

Q3 Dentistry
Ö. Bilgin, D. Altunbaş
{"title":"五种不同镍钛旋转锉系统在模拟渠道中成形能力的比较评价","authors":"Ö. Bilgin, D. Altunbaş","doi":"10.7126/cumudj.1204170","DOIUrl":null,"url":null,"abstract":"Objectives: The aim of this study was to compare the simulated canal shaping efficiencies of five different NiTi rotary file systems. \nMaterials and Methods: In the study, 100 transparent resin blocks with J-shaped canals were randomly divided into five groups (n=20). Simulated canals were shaped with VDW.Rotate (VR), TruNatomy (TRN), HyFlex CM (HF), EdgeFile X7 (EF), or ProTaper Next (PTN) files. Ten measuring points were detected on the pre- and post-preparation images taken from the blocks and superimposed. After preparation, the total canal width and the amount of transportation were calculated for the determined measuring levels. Zipping and ledge formation, instrument fracture and deformation, and change in working length were evaluated. The data were statistically analyzed with the Kolmogorov-Smirnov test, one-way ANOVA, Tukey test, Chi-Square test, and a Monte Carlo version of the Fisher Exact tests. The error level was taken as 0.05. \nResults: There were significant differences between the groups at all measuring levels in terms of total canal width after instrumentation (p = 0.001). Significant differences in the amount of transportation were found between the groups (p = 0.001) except at levels 4 (p = 0.169) and 10 (p = 0.054). Zip and instrument fractures did not occur in any group. 3 EF size 25/.04 files were deformed (p = 0.021). There was no significant difference between the groups in terms of ledge formation and working length change (p > 0.05). \nConclusions: According to findings obtained in the study, transportation occurred at all 10 measuring levels with all file systems used. HF and EF systems were found to be more reliable in terms of transportation in the middle and coronal regions. Wider canal preparation was obtained with the PTN system in the middle and coronal regions.","PeriodicalId":10781,"journal":{"name":"Cumhuriyet Dental Journal","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-12-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative Evaluation of the Shaping Ability of Five Different Nickel-Titanium Rotary File Systems in Simulated Canals\",\"authors\":\"Ö. Bilgin, D. Altunbaş\",\"doi\":\"10.7126/cumudj.1204170\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objectives: The aim of this study was to compare the simulated canal shaping efficiencies of five different NiTi rotary file systems. \\nMaterials and Methods: In the study, 100 transparent resin blocks with J-shaped canals were randomly divided into five groups (n=20). Simulated canals were shaped with VDW.Rotate (VR), TruNatomy (TRN), HyFlex CM (HF), EdgeFile X7 (EF), or ProTaper Next (PTN) files. Ten measuring points were detected on the pre- and post-preparation images taken from the blocks and superimposed. After preparation, the total canal width and the amount of transportation were calculated for the determined measuring levels. Zipping and ledge formation, instrument fracture and deformation, and change in working length were evaluated. The data were statistically analyzed with the Kolmogorov-Smirnov test, one-way ANOVA, Tukey test, Chi-Square test, and a Monte Carlo version of the Fisher Exact tests. The error level was taken as 0.05. \\nResults: There were significant differences between the groups at all measuring levels in terms of total canal width after instrumentation (p = 0.001). Significant differences in the amount of transportation were found between the groups (p = 0.001) except at levels 4 (p = 0.169) and 10 (p = 0.054). Zip and instrument fractures did not occur in any group. 3 EF size 25/.04 files were deformed (p = 0.021). There was no significant difference between the groups in terms of ledge formation and working length change (p > 0.05). \\nConclusions: According to findings obtained in the study, transportation occurred at all 10 measuring levels with all file systems used. HF and EF systems were found to be more reliable in terms of transportation in the middle and coronal regions. Wider canal preparation was obtained with the PTN system in the middle and coronal regions.\",\"PeriodicalId\":10781,\"journal\":{\"name\":\"Cumhuriyet Dental Journal\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-12-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cumhuriyet Dental Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.7126/cumudj.1204170\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cumhuriyet Dental Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7126/cumudj.1204170","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究的目的是比较五种不同NiTi旋转锉系统的模拟椎管成形效率。材料与方法:将100块J型透明树脂块随机分为5组(n=20)。使用VDW.Rotate(VR)、TruNatomy(TRN)、HyFlex CM(HF)、EdgeFile X7(EF)或ProTaper Next(PTN)文件对模拟管进行整形。在制备前和制备后的图像上检测到10个测量点,这些图像取自试块并叠加。准备完成后,针对确定的测量水平计算运河总宽度和运输量。评估了拉链和横档的形成、器械的断裂和变形以及工作长度的变化。使用Kolmogorov-Smirnov检验、单因素方差分析、Tukey检验、卡方检验和Fisher精确检验的蒙特卡罗版本对数据进行统计分析。误差水平取0.05。结果:在所有测量水平上,两组在器械植入后的总管宽度方面均存在显著差异(p=0.001)。除4级(p=0.169)和10级(p=0.054)外,两组之间在运输量方面均存在明显差异(p=0.0001)。任何一组均未发生拉链和器械骨折。3 EF大小25/.04的锉刀发生了变形(p=0.021)。两组在凸缘形成和工作长度变化方面没有显著差异(p>0.05)。结论:根据研究结果,在使用所有文件系统的情况下,在所有10个测量水平上都发生了迁移。HF和EF系统被发现在中部和冠状区域的运输方面更可靠。在正中和冠状区域使用PTN系统获得更宽的管预备。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparative Evaluation of the Shaping Ability of Five Different Nickel-Titanium Rotary File Systems in Simulated Canals
Objectives: The aim of this study was to compare the simulated canal shaping efficiencies of five different NiTi rotary file systems. Materials and Methods: In the study, 100 transparent resin blocks with J-shaped canals were randomly divided into five groups (n=20). Simulated canals were shaped with VDW.Rotate (VR), TruNatomy (TRN), HyFlex CM (HF), EdgeFile X7 (EF), or ProTaper Next (PTN) files. Ten measuring points were detected on the pre- and post-preparation images taken from the blocks and superimposed. After preparation, the total canal width and the amount of transportation were calculated for the determined measuring levels. Zipping and ledge formation, instrument fracture and deformation, and change in working length were evaluated. The data were statistically analyzed with the Kolmogorov-Smirnov test, one-way ANOVA, Tukey test, Chi-Square test, and a Monte Carlo version of the Fisher Exact tests. The error level was taken as 0.05. Results: There were significant differences between the groups at all measuring levels in terms of total canal width after instrumentation (p = 0.001). Significant differences in the amount of transportation were found between the groups (p = 0.001) except at levels 4 (p = 0.169) and 10 (p = 0.054). Zip and instrument fractures did not occur in any group. 3 EF size 25/.04 files were deformed (p = 0.021). There was no significant difference between the groups in terms of ledge formation and working length change (p > 0.05). Conclusions: According to findings obtained in the study, transportation occurred at all 10 measuring levels with all file systems used. HF and EF systems were found to be more reliable in terms of transportation in the middle and coronal regions. Wider canal preparation was obtained with the PTN system in the middle and coronal regions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Cumhuriyet Dental Journal
Cumhuriyet Dental Journal Dentistry-Dentistry (all)
CiteScore
0.40
自引率
0.00%
发文量
0
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信