R407C、R404A和R134A作为R22替代品在循环条件下的不可逆性分析

Pub Date : 2021-02-28 DOI:10.5541/IJOT.797614
Ayad Khudhair Al-Nadawi
{"title":"R407C、R404A和R134A作为R22替代品在循环条件下的不可逆性分析","authors":"Ayad Khudhair Al-Nadawi","doi":"10.5541/IJOT.797614","DOIUrl":null,"url":null,"abstract":"This paper presents irreversibility analysis using experimental data from vapor compression chiller system using R22, R407C, R404A and R-134A as working fluids. The system operated under cycling condition, which allowing the water to circulate in the evaporator and recording data every ten minutes. Further, the experimental study was conducted at different water and ambient temperature to identify the parameter that cause the energy deterioration. The findings show that the total irreversibility increases at high water mass flow rate. Additionally, high ambient temperature increase the irreversibility of the system. R134A and R407C are a good replacement for R22 in terms of irreversibility analysis during cycling condition.","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-02-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Irreversibility Analysis of R407C, R404A, and R134A as an Alternatives of R22 in Vapor Compression Chiller under Cycling Conditions\",\"authors\":\"Ayad Khudhair Al-Nadawi\",\"doi\":\"10.5541/IJOT.797614\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents irreversibility analysis using experimental data from vapor compression chiller system using R22, R407C, R404A and R-134A as working fluids. The system operated under cycling condition, which allowing the water to circulate in the evaporator and recording data every ten minutes. Further, the experimental study was conducted at different water and ambient temperature to identify the parameter that cause the energy deterioration. The findings show that the total irreversibility increases at high water mass flow rate. Additionally, high ambient temperature increase the irreversibility of the system. R134A and R407C are a good replacement for R22 in terms of irreversibility analysis during cycling condition.\",\"PeriodicalId\":0,\"journal\":{\"name\":\"\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0,\"publicationDate\":\"2021-02-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5541/IJOT.797614\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5541/IJOT.797614","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本文利用R22、R407C、R404A和R-134A作为工质的蒸汽压缩制冷机系统的实验数据进行了不可逆性分析。系统在循环工况下运行,使水在蒸发器中循环,每十分钟记录一次数据。在不同的水温和环境温度下进行了实验研究,找出了导致能量劣化的参数。研究结果表明,在高水流量条件下,总不可逆性增大。此外,高环境温度增加了系统的不可逆性。R134A和R407C在循环条件下的不可逆性分析方面是R22的良好替代品。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享
查看原文
Irreversibility Analysis of R407C, R404A, and R134A as an Alternatives of R22 in Vapor Compression Chiller under Cycling Conditions
This paper presents irreversibility analysis using experimental data from vapor compression chiller system using R22, R407C, R404A and R-134A as working fluids. The system operated under cycling condition, which allowing the water to circulate in the evaporator and recording data every ten minutes. Further, the experimental study was conducted at different water and ambient temperature to identify the parameter that cause the energy deterioration. The findings show that the total irreversibility increases at high water mass flow rate. Additionally, high ambient temperature increase the irreversibility of the system. R134A and R407C are a good replacement for R22 in terms of irreversibility analysis during cycling condition.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信