{"title":"x支撑型特殊桁架弯矩框架抗震性能:建筑高度的影响","authors":"Hidajat Sugihardjo, A. B. Habieb, Robi Karuniawan","doi":"10.2478/cee-2022-0058","DOIUrl":null,"url":null,"abstract":"Abstract This study investigated the implementation of Special Truss Moment Frames (STMF) X-braced type in accordance with the recommendations of the National Earthquake Hazards Reduction Program (NEHRP), 1997:2000 and Indonesian National Standards (SNI) 1726 where it is stated that the STMF may only be used up to a maximum building height of 48 m (160 feet) for Seismic Design Category of D. The analyses compared the seismic response of apartment buildings using STMF system with different height: 44 m (11 stories), 48 m (12 stories), and 52 m (13 stories). The nonlinear behaviors were investigated through a series of nonlinear time history and pushover analyses, including the inelastic response of the structural components, top-roof displacement, drift ratio, and ductility. The structural modeling and the selection of steel sections were performed in SAP 2000 based on SNI 1726 code, considering that the structure was built on medium soil in Aceh region. Seismic performance was examined through a series of pushover and nonlinear time history analysis (NLTHA) using three scaled accelerogram: Elcentro 1940, Northridge 1994 and Kobe 1995 records. The results of the study show that in case of STMF structure with the height of 52 m (higher than the maximum height of STMF structure stated in the codes), the seismic performance of the structure was excellent and met the requirements. Axial plasticization occurred only in X-braces, not followed by the formation of plastic hinges at the ends of the ductile segments. Meanwhile, the other structural components remained elastic. This indicates that the structure can still be used after the earthquake, by replacing only the X-braced components. The drift ratio met the requirements and the roof displacements behavior was asymptotic, indicating that there is no residual horizontal displacement of the building after the seismic loads occurred.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2022-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Seismic Performance of Special Truss Moment Frames With X-Bracing Type: Influence of Building Height\",\"authors\":\"Hidajat Sugihardjo, A. B. Habieb, Robi Karuniawan\",\"doi\":\"10.2478/cee-2022-0058\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract This study investigated the implementation of Special Truss Moment Frames (STMF) X-braced type in accordance with the recommendations of the National Earthquake Hazards Reduction Program (NEHRP), 1997:2000 and Indonesian National Standards (SNI) 1726 where it is stated that the STMF may only be used up to a maximum building height of 48 m (160 feet) for Seismic Design Category of D. The analyses compared the seismic response of apartment buildings using STMF system with different height: 44 m (11 stories), 48 m (12 stories), and 52 m (13 stories). The nonlinear behaviors were investigated through a series of nonlinear time history and pushover analyses, including the inelastic response of the structural components, top-roof displacement, drift ratio, and ductility. The structural modeling and the selection of steel sections were performed in SAP 2000 based on SNI 1726 code, considering that the structure was built on medium soil in Aceh region. Seismic performance was examined through a series of pushover and nonlinear time history analysis (NLTHA) using three scaled accelerogram: Elcentro 1940, Northridge 1994 and Kobe 1995 records. The results of the study show that in case of STMF structure with the height of 52 m (higher than the maximum height of STMF structure stated in the codes), the seismic performance of the structure was excellent and met the requirements. Axial plasticization occurred only in X-braces, not followed by the formation of plastic hinges at the ends of the ductile segments. Meanwhile, the other structural components remained elastic. This indicates that the structure can still be used after the earthquake, by replacing only the X-braced components. The drift ratio met the requirements and the roof displacements behavior was asymptotic, indicating that there is no residual horizontal displacement of the building after the seismic loads occurred.\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2022-11-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2478/cee-2022-0058\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/cee-2022-0058","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Seismic Performance of Special Truss Moment Frames With X-Bracing Type: Influence of Building Height
Abstract This study investigated the implementation of Special Truss Moment Frames (STMF) X-braced type in accordance with the recommendations of the National Earthquake Hazards Reduction Program (NEHRP), 1997:2000 and Indonesian National Standards (SNI) 1726 where it is stated that the STMF may only be used up to a maximum building height of 48 m (160 feet) for Seismic Design Category of D. The analyses compared the seismic response of apartment buildings using STMF system with different height: 44 m (11 stories), 48 m (12 stories), and 52 m (13 stories). The nonlinear behaviors were investigated through a series of nonlinear time history and pushover analyses, including the inelastic response of the structural components, top-roof displacement, drift ratio, and ductility. The structural modeling and the selection of steel sections were performed in SAP 2000 based on SNI 1726 code, considering that the structure was built on medium soil in Aceh region. Seismic performance was examined through a series of pushover and nonlinear time history analysis (NLTHA) using three scaled accelerogram: Elcentro 1940, Northridge 1994 and Kobe 1995 records. The results of the study show that in case of STMF structure with the height of 52 m (higher than the maximum height of STMF structure stated in the codes), the seismic performance of the structure was excellent and met the requirements. Axial plasticization occurred only in X-braces, not followed by the formation of plastic hinges at the ends of the ductile segments. Meanwhile, the other structural components remained elastic. This indicates that the structure can still be used after the earthquake, by replacing only the X-braced components. The drift ratio met the requirements and the roof displacements behavior was asymptotic, indicating that there is no residual horizontal displacement of the building after the seismic loads occurred.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.