聚焦超声的个性化闭环反馈控制打开血脑屏障。

IF 5 Q1 ENGINEERING, BIOMEDICAL
BME frontiers Pub Date : 2022-04-05 eCollection Date: 2022-01-01 DOI:10.34133/2022/9867230
Chih-Yen Chien, Yaoheng Yang, Yan Gong, Yimei Yue, Hong Chen
{"title":"聚焦超声的个性化闭环反馈控制打开血脑屏障。","authors":"Chih-Yen Chien, Yaoheng Yang, Yan Gong, Yimei Yue, Hong Chen","doi":"10.34133/2022/9867230","DOIUrl":null,"url":null,"abstract":"<p><p><i>Objective and Impact Statement</i>. To develop an approach for individualized closed-loop feedback control of microbubble cavitation to achieve safe and effective focused ultrasound in combination with microbubble-induced blood-brain barrier opening (FUS-BBBO). <i>Introduction</i>. FUS-BBBO is a promising strategy for noninvasive and localized brain drug delivery with a growing number of clinical studies currently ongoing. Real-time cavitation monitoring and feedback control are critical to achieving safe and effective FUS-BBBO. However, feedback control algorithms used in the past were either open-loop or without consideration of baseline cavitation level difference among subjects. <i>Methods</i>. This study performed feedback-controlled FUS-BBBO by defining the target cavitation level based on the baseline stable cavitation level of an individual subject with \"dummy\" FUS sonication. The dummy FUS sonication applied FUS with a low acoustic pressure for a short duration in the presence of microbubbles to define the baseline stable cavitation level that took into consideration of individual differences in the detected cavitation emissions. FUS-BBBO was then achieved through two sonication phases: ramping-up phase to reach the target cavitation level and maintaining phase to control the stable cavitation level at the target cavitation level. <i>Results</i>. Evaluations performed in wild-type mice demonstrated that this approach achieved effective and safe trans-BBB delivery of a model drug. The drug delivery efficiency increased as the target cavitation level increased from 0.5 dB to 2 dB without causing vascular damage. Increasing the target cavitation level to 3 dB and 4 dB increased the probability of tissue damage. <i>Conclusions</i>. Safe and effective brain drug delivery was achieved using the individualized closed-loop feedback-controlled FUS-BBBO.</p>","PeriodicalId":72430,"journal":{"name":"BME frontiers","volume":"2022 ","pages":"9867230"},"PeriodicalIF":5.0000,"publicationDate":"2022-04-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10521637/pdf/","citationCount":"0","resultStr":"{\"title\":\"Blood-Brain Barrier Opening by Individualized Closed-Loop Feedback Control of Focused Ultrasound.\",\"authors\":\"Chih-Yen Chien, Yaoheng Yang, Yan Gong, Yimei Yue, Hong Chen\",\"doi\":\"10.34133/2022/9867230\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><i>Objective and Impact Statement</i>. To develop an approach for individualized closed-loop feedback control of microbubble cavitation to achieve safe and effective focused ultrasound in combination with microbubble-induced blood-brain barrier opening (FUS-BBBO). <i>Introduction</i>. FUS-BBBO is a promising strategy for noninvasive and localized brain drug delivery with a growing number of clinical studies currently ongoing. Real-time cavitation monitoring and feedback control are critical to achieving safe and effective FUS-BBBO. However, feedback control algorithms used in the past were either open-loop or without consideration of baseline cavitation level difference among subjects. <i>Methods</i>. This study performed feedback-controlled FUS-BBBO by defining the target cavitation level based on the baseline stable cavitation level of an individual subject with \\\"dummy\\\" FUS sonication. The dummy FUS sonication applied FUS with a low acoustic pressure for a short duration in the presence of microbubbles to define the baseline stable cavitation level that took into consideration of individual differences in the detected cavitation emissions. FUS-BBBO was then achieved through two sonication phases: ramping-up phase to reach the target cavitation level and maintaining phase to control the stable cavitation level at the target cavitation level. <i>Results</i>. Evaluations performed in wild-type mice demonstrated that this approach achieved effective and safe trans-BBB delivery of a model drug. The drug delivery efficiency increased as the target cavitation level increased from 0.5 dB to 2 dB without causing vascular damage. Increasing the target cavitation level to 3 dB and 4 dB increased the probability of tissue damage. <i>Conclusions</i>. Safe and effective brain drug delivery was achieved using the individualized closed-loop feedback-controlled FUS-BBBO.</p>\",\"PeriodicalId\":72430,\"journal\":{\"name\":\"BME frontiers\",\"volume\":\"2022 \",\"pages\":\"9867230\"},\"PeriodicalIF\":5.0000,\"publicationDate\":\"2022-04-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10521637/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"BME frontiers\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.34133/2022/9867230\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"BME frontiers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.34133/2022/9867230","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

目标和影响声明。开发一种对微气泡空化进行个性化闭环反馈控制的方法,以实现安全有效的聚焦超声与微气泡诱导的血脑屏障开放(FUS-BBBO)相结合。介绍FUS-BBBO是一种很有前途的非侵入性和局部脑给药策略,目前正在进行越来越多的临床研究。实时空化监测和反馈控制对于实现安全有效的FUS-BBBO至关重要。然而,过去使用的反馈控制算法要么是开环的,要么没有考虑受试者之间的基线空化水平差异。方法。本研究通过基于具有“伪”FUS超声处理的个体受试者的基线稳定空化水平来定义目标空化水平,来执行反馈控制的FUS-BBBO。在存在微气泡的情况下,伪FUS超声处理在短时间内以低声压应用FUS,以确定基线稳定空化水平,该水平考虑了检测到的空化发射的个体差异。然后通过两个超声处理阶段实现FUS-BBBO:上升阶段以达到目标空化水平,维持阶段以将稳定的空化水平控制在目标空化水平。后果在野生型小鼠中进行的评估表明,这种方法实现了模型药物的有效和安全的跨血脑屏障递送。药物递送效率随着目标空化水平从0.5增加而增加 dB至2 dB而不会造成血管损伤。将目标空化水平提高到3 dB和4 dB增加了组织损伤的概率。结论。使用个体化闭环反馈控制的FUS-BBBO实现了安全有效的脑药物递送。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Blood-Brain Barrier Opening by Individualized Closed-Loop Feedback Control of Focused Ultrasound.

Objective and Impact Statement. To develop an approach for individualized closed-loop feedback control of microbubble cavitation to achieve safe and effective focused ultrasound in combination with microbubble-induced blood-brain barrier opening (FUS-BBBO). Introduction. FUS-BBBO is a promising strategy for noninvasive and localized brain drug delivery with a growing number of clinical studies currently ongoing. Real-time cavitation monitoring and feedback control are critical to achieving safe and effective FUS-BBBO. However, feedback control algorithms used in the past were either open-loop or without consideration of baseline cavitation level difference among subjects. Methods. This study performed feedback-controlled FUS-BBBO by defining the target cavitation level based on the baseline stable cavitation level of an individual subject with "dummy" FUS sonication. The dummy FUS sonication applied FUS with a low acoustic pressure for a short duration in the presence of microbubbles to define the baseline stable cavitation level that took into consideration of individual differences in the detected cavitation emissions. FUS-BBBO was then achieved through two sonication phases: ramping-up phase to reach the target cavitation level and maintaining phase to control the stable cavitation level at the target cavitation level. Results. Evaluations performed in wild-type mice demonstrated that this approach achieved effective and safe trans-BBB delivery of a model drug. The drug delivery efficiency increased as the target cavitation level increased from 0.5 dB to 2 dB without causing vascular damage. Increasing the target cavitation level to 3 dB and 4 dB increased the probability of tissue damage. Conclusions. Safe and effective brain drug delivery was achieved using the individualized closed-loop feedback-controlled FUS-BBBO.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
7.10
自引率
0.00%
发文量
0
审稿时长
16 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信