股腘动脉超声矢量流成像在外周动脉疾病中的首次经验。

IF 2.1 4区 医学 Q3 PERIPHERAL VASCULAR DISEASE
Tetyana Shchetynska-Marinova, Laurin Gerdes, Anna-Lena Hohneck, Laura Winter, Klaus Amendt, Kay Schwenke, Andreas L H Gerken, Yigang Du, Daniel Dürschmied, Martin Sigl
{"title":"股腘动脉超声矢量流成像在外周动脉疾病中的首次经验。","authors":"Tetyana Shchetynska-Marinova, Laurin Gerdes, Anna-Lena Hohneck, Laura Winter, Klaus Amendt, Kay Schwenke, Andreas L H Gerken, Yigang Du, Daniel Dürschmied, Martin Sigl","doi":"10.1024/0301-1526/a001095","DOIUrl":null,"url":null,"abstract":"<p><p><b></b> <i>Background:</i> The femoropopliteal artery (FPA) plays a central role in diagnosing and treating peripheral arterial disease (PAD). FPA lesions are the most frequent cause of intermittent claudication, and no other artery of the lower extremities is recanalised more frequently. Generally, ultrasound is the primary imaging tool in PAD, particularly FPA. With the development of high-frame-rate ultrasound technology in addition to traditional ultrasound modes, vector flow imaging (VFI) has provided deeper haemodynamic insights when used in the carotid artery. Here, we report the use of VFI at the FPA level in routine PAD examinations. <i>Patients and methods:</i> In this single-centre prospective study, we evaluated consecutive patients with PAD using B-mode imaging, colour Doppler, pulsed wave Doppler (PW) and vector flow. Hemodynamic parameters at predefined locations at the carotid artery and FPA were compared. <i>Results:</i> Qualitatively adequate VFI at all sites was possible in 76% of the patients with PAD. With decreasing volume flow from the common carotid artery to the internal carotid artery and from the common femoral artery via the superficial femoral artery to the popliteal artery, the correlation between VFI- and PW-derived-volume flow was high at every site. Based on different techniques, the VFI-derived values were significantly lower than the PW-derived values. The mean wall shear stress was significantly lower at all femoropopliteal sites than at the carotid sites, whereas the oscillatory shear index at the femoral site was higher than that at the carotid sites rather than at the popliteal location. <i>Conclusions:</i> Our findings suggest that vector flow data acquisition in the FPA is feasible in most patients with PAD. Therefore, with knowledge of the method and its limitations, VFI provides haemodynamic information beyond traditional ultrasound techniques and is a promising new tool for flow analysis in PAD.</p>","PeriodicalId":23528,"journal":{"name":"Vasa-european Journal of Vascular Medicine","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"First experiences of ultrasound vector flow imaging at the femoropopliteal artery in peripheral arterial disease.\",\"authors\":\"Tetyana Shchetynska-Marinova, Laurin Gerdes, Anna-Lena Hohneck, Laura Winter, Klaus Amendt, Kay Schwenke, Andreas L H Gerken, Yigang Du, Daniel Dürschmied, Martin Sigl\",\"doi\":\"10.1024/0301-1526/a001095\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b></b> <i>Background:</i> The femoropopliteal artery (FPA) plays a central role in diagnosing and treating peripheral arterial disease (PAD). FPA lesions are the most frequent cause of intermittent claudication, and no other artery of the lower extremities is recanalised more frequently. Generally, ultrasound is the primary imaging tool in PAD, particularly FPA. With the development of high-frame-rate ultrasound technology in addition to traditional ultrasound modes, vector flow imaging (VFI) has provided deeper haemodynamic insights when used in the carotid artery. Here, we report the use of VFI at the FPA level in routine PAD examinations. <i>Patients and methods:</i> In this single-centre prospective study, we evaluated consecutive patients with PAD using B-mode imaging, colour Doppler, pulsed wave Doppler (PW) and vector flow. Hemodynamic parameters at predefined locations at the carotid artery and FPA were compared. <i>Results:</i> Qualitatively adequate VFI at all sites was possible in 76% of the patients with PAD. With decreasing volume flow from the common carotid artery to the internal carotid artery and from the common femoral artery via the superficial femoral artery to the popliteal artery, the correlation between VFI- and PW-derived-volume flow was high at every site. Based on different techniques, the VFI-derived values were significantly lower than the PW-derived values. The mean wall shear stress was significantly lower at all femoropopliteal sites than at the carotid sites, whereas the oscillatory shear index at the femoral site was higher than that at the carotid sites rather than at the popliteal location. <i>Conclusions:</i> Our findings suggest that vector flow data acquisition in the FPA is feasible in most patients with PAD. Therefore, with knowledge of the method and its limitations, VFI provides haemodynamic information beyond traditional ultrasound techniques and is a promising new tool for flow analysis in PAD.</p>\",\"PeriodicalId\":23528,\"journal\":{\"name\":\"Vasa-european Journal of Vascular Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2023-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Vasa-european Journal of Vascular Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1024/0301-1526/a001095\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/10/17 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"PERIPHERAL VASCULAR DISEASE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vasa-european Journal of Vascular Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1024/0301-1526/a001095","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/10/17 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

摘要

背景:股腘动脉(FPA)在外周动脉疾病(PAD)的诊断和治疗中起着核心作用。FPA病变是间歇性跛行最常见的原因,没有其他下肢动脉再通的频率更高。一般来说,超声是PAD的主要成像工具,尤其是FPA。除了传统的超声模式外,随着高帧率超声技术的发展,矢量流成像(VFI)在颈动脉中使用时提供了更深入的血液动力学见解。在这里,我们报告了在常规PAD检查中使用FPA水平的VFI。患者和方法:在这项单中心前瞻性研究中,我们使用B模式成像、彩色多普勒、脉冲波多普勒(PW)和矢量流对连续的PAD患者进行了评估。比较颈动脉和FPA预定位置的血流动力学参数。结果:76%的PAD患者可以在所有部位进行定性的充分VFI。随着从颈总动脉到颈内动脉以及从股总动脉经股浅动脉到腘动脉的体积流量的减少,VFI和PW衍生的体积流量之间的相关性在每个部位都很高。基于不同的技术,VFI导出的值明显低于PW导出的值。股骨-腘窝所有部位的平均壁剪切应力均显著低于颈动脉部位,而股骨部位的振荡剪切指数高于颈动脉部位而非腘窝部位。结论:我们的研究结果表明,在大多数PAD患者中,FPA中的矢量流数据采集是可行的。因此,根据对该方法及其局限性的了解,VFI提供了传统超声技术之外的血液动力学信息,是PAD血流分析的一种有前途的新工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
First experiences of ultrasound vector flow imaging at the femoropopliteal artery in peripheral arterial disease.

Background: The femoropopliteal artery (FPA) plays a central role in diagnosing and treating peripheral arterial disease (PAD). FPA lesions are the most frequent cause of intermittent claudication, and no other artery of the lower extremities is recanalised more frequently. Generally, ultrasound is the primary imaging tool in PAD, particularly FPA. With the development of high-frame-rate ultrasound technology in addition to traditional ultrasound modes, vector flow imaging (VFI) has provided deeper haemodynamic insights when used in the carotid artery. Here, we report the use of VFI at the FPA level in routine PAD examinations. Patients and methods: In this single-centre prospective study, we evaluated consecutive patients with PAD using B-mode imaging, colour Doppler, pulsed wave Doppler (PW) and vector flow. Hemodynamic parameters at predefined locations at the carotid artery and FPA were compared. Results: Qualitatively adequate VFI at all sites was possible in 76% of the patients with PAD. With decreasing volume flow from the common carotid artery to the internal carotid artery and from the common femoral artery via the superficial femoral artery to the popliteal artery, the correlation between VFI- and PW-derived-volume flow was high at every site. Based on different techniques, the VFI-derived values were significantly lower than the PW-derived values. The mean wall shear stress was significantly lower at all femoropopliteal sites than at the carotid sites, whereas the oscillatory shear index at the femoral site was higher than that at the carotid sites rather than at the popliteal location. Conclusions: Our findings suggest that vector flow data acquisition in the FPA is feasible in most patients with PAD. Therefore, with knowledge of the method and its limitations, VFI provides haemodynamic information beyond traditional ultrasound techniques and is a promising new tool for flow analysis in PAD.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.90
自引率
11.10%
发文量
61
审稿时长
1 months
期刊介绍: Vasa is the European journal of vascular medicine. It is the official organ of the German, Swiss, and Slovenian Societies of Angiology. The journal publishes original research articles, case reports and reviews on vascular biology, epidemiology, prevention, diagnosis, medical treatment and interventions for diseases of the arterial circulation, in the field of phlebology and lymphology including the microcirculation, except the cardiac circulation. Vasa combines basic science with clinical medicine making it relevant to all physicians interested in the whole vascular field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信