用于提供眼镜处方的客观双目自动验光仪的准确性。

IF 1.7 4区 医学 Q3 OPHTHALMOLOGY
Clinical and Experimental Optometry Pub Date : 2024-09-01 Epub Date: 2023-10-16 DOI:10.1080/08164622.2023.2266498
Erol Ozgur, Pierre-Alexandre Blanche, Edward J Bedrick, Mandi D Conway, Gholam A Peyman, Nasser N Peyghambarian
{"title":"用于提供眼镜处方的客观双目自动验光仪的准确性。","authors":"Erol Ozgur, Pierre-Alexandre Blanche, Edward J Bedrick, Mandi D Conway, Gholam A Peyman, Nasser N Peyghambarian","doi":"10.1080/08164622.2023.2266498","DOIUrl":null,"url":null,"abstract":"<p><strong>Clinical relevance: </strong>Currently eye examinations are usually based on autorefraction followed by subjective refraction (SR) with a phoropter. An automated phoropter that can also perform autorefraction may facilitate the optometric workflow.</p><p><strong>Background: </strong>The efficiency and feasibility of an objective autorefraction and correction system are assessed by comparing objective refractive measurements with SR on the same subjects and evaluating the visual acuity (VA) values obtained after the objective refractive measurement and correction.</p><p><strong>Methods: </strong>Objective autorefraction and correction was performed on 41 subjects using an automated binocular phoropter system. The auto-phoropter performs autorefraction by wavefront measurement and corrects the spherical and cylindrical errors with tunable fluidic lenses while the patient looks at a visual display inside the instrument. The instrument outputs are optometric constants of spherical and cylindrical aberrations. After measurement and automated correction of the refractive errors, the VA values were assessed by having the subjects look at an integrated Snellen chart. The objective measurement results were statistically compared with their SR.</p><p><strong>Results: </strong>The correlations between SR and objective autorefraction and correction spherical equivalents (M) were 0.98 (0.97-0.99) and 0.96 (0.93-0.98), the vertical Jackson cross cylinder (J<sub>0</sub>) were 0.96 (0.92-0.98) and 0.95 (0.91-0.97), and the oblique Jackson cross cylinder (J<sub>45</sub>) were 0.73 (0.55-0.85) and 0.82 (0.69-0.90), for the right and left eyes, respectively, with the 95% confidence interval (CI) values in parentheses. 89.0% of the 82 eyes had at least 6/7.5 VA.</p><p><strong>Conclusions: </strong>A significant agreement between the SR and objective autorefraction and correction was observed. An all-objective refractive assessment with instantaneous verification may improve the precision of eye prescriptions and possibly reduce the procedure time.</p>","PeriodicalId":10214,"journal":{"name":"Clinical and Experimental Optometry","volume":" ","pages":"698-703"},"PeriodicalIF":1.7000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Accuracy of an objective binocular automated phoropter for providing spectacle prescriptions.\",\"authors\":\"Erol Ozgur, Pierre-Alexandre Blanche, Edward J Bedrick, Mandi D Conway, Gholam A Peyman, Nasser N Peyghambarian\",\"doi\":\"10.1080/08164622.2023.2266498\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Clinical relevance: </strong>Currently eye examinations are usually based on autorefraction followed by subjective refraction (SR) with a phoropter. An automated phoropter that can also perform autorefraction may facilitate the optometric workflow.</p><p><strong>Background: </strong>The efficiency and feasibility of an objective autorefraction and correction system are assessed by comparing objective refractive measurements with SR on the same subjects and evaluating the visual acuity (VA) values obtained after the objective refractive measurement and correction.</p><p><strong>Methods: </strong>Objective autorefraction and correction was performed on 41 subjects using an automated binocular phoropter system. The auto-phoropter performs autorefraction by wavefront measurement and corrects the spherical and cylindrical errors with tunable fluidic lenses while the patient looks at a visual display inside the instrument. The instrument outputs are optometric constants of spherical and cylindrical aberrations. After measurement and automated correction of the refractive errors, the VA values were assessed by having the subjects look at an integrated Snellen chart. The objective measurement results were statistically compared with their SR.</p><p><strong>Results: </strong>The correlations between SR and objective autorefraction and correction spherical equivalents (M) were 0.98 (0.97-0.99) and 0.96 (0.93-0.98), the vertical Jackson cross cylinder (J<sub>0</sub>) were 0.96 (0.92-0.98) and 0.95 (0.91-0.97), and the oblique Jackson cross cylinder (J<sub>45</sub>) were 0.73 (0.55-0.85) and 0.82 (0.69-0.90), for the right and left eyes, respectively, with the 95% confidence interval (CI) values in parentheses. 89.0% of the 82 eyes had at least 6/7.5 VA.</p><p><strong>Conclusions: </strong>A significant agreement between the SR and objective autorefraction and correction was observed. An all-objective refractive assessment with instantaneous verification may improve the precision of eye prescriptions and possibly reduce the procedure time.</p>\",\"PeriodicalId\":10214,\"journal\":{\"name\":\"Clinical and Experimental Optometry\",\"volume\":\" \",\"pages\":\"698-703\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical and Experimental Optometry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/08164622.2023.2266498\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/10/16 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical and Experimental Optometry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/08164622.2023.2266498","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/10/16 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

临床相关性:目前的眼部检查通常是基于自动屈光,然后用验光仪进行主观屈光(SR)。也可以进行自动验光的自动验光仪可以促进验光工作流程。背景:通过比较相同受试者的客观屈光测量值和SR,并评估客观屈光测量和校正后获得的视力(VA)值,评估客观自动折射和校正系统的效率和可行性。方法:采用双目自动验光仪对41例受试者进行客观自动验光和矫正。自动验光仪通过波前测量进行自动折射,并在患者观看仪器内部的视觉显示器时,使用可调谐流体透镜校正球面和柱面误差。仪器输出是球面像差和柱面像差的验光常数。在测量和自动校正屈光不正后,通过让受试者查看综合Snellen图表来评估VA值。结果:SR与目标自折射和校正球当量(M)的相关性分别为0.98(0.97-0.99)和0.96(0.93-0.98,分别用于右眼和左眼,括号中为95%置信区间(CI)值。82眼中89.0%的患者至少有6/7.5 VA。结论:SR与客观自动折射和矫正之间存在显著一致性。即时验证的全客观屈光评估可以提高眼科处方的准确性,并可能缩短手术时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Accuracy of an objective binocular automated phoropter for providing spectacle prescriptions.

Clinical relevance: Currently eye examinations are usually based on autorefraction followed by subjective refraction (SR) with a phoropter. An automated phoropter that can also perform autorefraction may facilitate the optometric workflow.

Background: The efficiency and feasibility of an objective autorefraction and correction system are assessed by comparing objective refractive measurements with SR on the same subjects and evaluating the visual acuity (VA) values obtained after the objective refractive measurement and correction.

Methods: Objective autorefraction and correction was performed on 41 subjects using an automated binocular phoropter system. The auto-phoropter performs autorefraction by wavefront measurement and corrects the spherical and cylindrical errors with tunable fluidic lenses while the patient looks at a visual display inside the instrument. The instrument outputs are optometric constants of spherical and cylindrical aberrations. After measurement and automated correction of the refractive errors, the VA values were assessed by having the subjects look at an integrated Snellen chart. The objective measurement results were statistically compared with their SR.

Results: The correlations between SR and objective autorefraction and correction spherical equivalents (M) were 0.98 (0.97-0.99) and 0.96 (0.93-0.98), the vertical Jackson cross cylinder (J0) were 0.96 (0.92-0.98) and 0.95 (0.91-0.97), and the oblique Jackson cross cylinder (J45) were 0.73 (0.55-0.85) and 0.82 (0.69-0.90), for the right and left eyes, respectively, with the 95% confidence interval (CI) values in parentheses. 89.0% of the 82 eyes had at least 6/7.5 VA.

Conclusions: A significant agreement between the SR and objective autorefraction and correction was observed. An all-objective refractive assessment with instantaneous verification may improve the precision of eye prescriptions and possibly reduce the procedure time.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.10
自引率
5.30%
发文量
132
审稿时长
6-12 weeks
期刊介绍: Clinical and Experimental Optometry is a peer reviewed journal listed by ISI and abstracted by PubMed, Web of Science, Scopus, Science Citation Index and Current Contents. It publishes original research papers and reviews in clinical optometry and vision science. Debate and discussion of controversial scientific and clinical issues is encouraged and letters to the Editor and short communications expressing points of view on matters within the Journal''s areas of interest are welcome. The Journal is published six times annually.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信