高海拔地区(海拔10000英尺)个体的眼压和角膜厚度评估。

Romanian journal of ophthalmology Pub Date : 2019-07-01
Arora Amit, Kapoor Gaurav, Ambiya Vikas, Kumar Ashok, A Singh Harpreet, Arora Shivani
{"title":"高海拔地区(海拔10000英尺)个体的眼压和角膜厚度评估。","authors":"Arora Amit, Kapoor Gaurav, Ambiya Vikas, Kumar Ashok, A Singh Harpreet, Arora Shivani","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background.</b> At high altitude changes in corneal thickness and intraocular pressure (IOP) has been a subject of investigation for decades. The mechanism of action of these changes is still unknown. Extensive research is carried out to know effect of hypoxia on humans at high altitude. Corneal thickness and intraocular pressure are important parameter in ophthalmology with both diagnostic and therapeutic implications. We studied the corneal thickness and intraocular pressure in highlanders and compared the same with lowlanders. <b>Methods.</b> This observational study included two groups, each consisting of 500 individuals residing at high altitude (more than 10,000 ft above sea level). Three measurements of intraocular pressure of both eyes in each group were noted with Goldmann applanation tonometer and mean of the three readings was taken. Central Corneal Thickness (CCT) was measured by ultra sound pachymetry. The parameters of two groups were compared statistically. <b>Results.</b> There was a statistically significant difference between corneal thicknesses of the two groups studied, however no overall statistically significant difference in intraocular pressure of both these groups was found. <b>Conclusion.</b> The highlanders have a thinner cornea as compared to lowlanders. The IOP is significantly higher in the highlander males as compared to lowlander males. However, the mean IOP is comparable between the overall population of the high altitude and that of low altitude.</p>","PeriodicalId":94355,"journal":{"name":"Romanian journal of ophthalmology","volume":"63 3","pages":"217-221"},"PeriodicalIF":0.0000,"publicationDate":"2019-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6820489/pdf/","citationCount":"0","resultStr":"{\"title\":\"Evaluation of intraocular pressure and corneal thickness in individuals at high altitude area (10000 ft above sea level).\",\"authors\":\"Arora Amit, Kapoor Gaurav, Ambiya Vikas, Kumar Ashok, A Singh Harpreet, Arora Shivani\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Background.</b> At high altitude changes in corneal thickness and intraocular pressure (IOP) has been a subject of investigation for decades. The mechanism of action of these changes is still unknown. Extensive research is carried out to know effect of hypoxia on humans at high altitude. Corneal thickness and intraocular pressure are important parameter in ophthalmology with both diagnostic and therapeutic implications. We studied the corneal thickness and intraocular pressure in highlanders and compared the same with lowlanders. <b>Methods.</b> This observational study included two groups, each consisting of 500 individuals residing at high altitude (more than 10,000 ft above sea level). Three measurements of intraocular pressure of both eyes in each group were noted with Goldmann applanation tonometer and mean of the three readings was taken. Central Corneal Thickness (CCT) was measured by ultra sound pachymetry. The parameters of two groups were compared statistically. <b>Results.</b> There was a statistically significant difference between corneal thicknesses of the two groups studied, however no overall statistically significant difference in intraocular pressure of both these groups was found. <b>Conclusion.</b> The highlanders have a thinner cornea as compared to lowlanders. The IOP is significantly higher in the highlander males as compared to lowlander males. However, the mean IOP is comparable between the overall population of the high altitude and that of low altitude.</p>\",\"PeriodicalId\":94355,\"journal\":{\"name\":\"Romanian journal of ophthalmology\",\"volume\":\"63 3\",\"pages\":\"217-221\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6820489/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Romanian journal of ophthalmology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Romanian journal of ophthalmology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景几十年来,在高海拔地区,角膜厚度和眼压的变化一直是研究的主题。这些变化的作用机制仍然未知。为了了解高海拔地区缺氧对人类的影响,人们进行了广泛的研究。角膜厚度和眼压是眼科的重要参数,具有诊断和治疗意义。我们研究了高地人的角膜厚度和眼压,并与低地人进行了比较。方法。这项观察性研究包括两组,每组由居住在高海拔(海拔超过10000英尺)的500人组成。用Goldmann压平眼压计记录各组双眼的三次眼压测量值,并取三次读数的平均值。用超声波测厚仪测量角膜中央厚度。对两组的参数进行统计学比较。后果研究的两组角膜厚度之间存在统计学显著差异,但这两组的眼压没有发现总体统计学显著差异。结论与低地人相比,高地人的角膜更薄。高地雄性的IOP明显高于低地雄性。然而,高海拔地区和低海拔地区的总人口的平均IOP是可比较的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of intraocular pressure and corneal thickness in individuals at high altitude area (10000 ft above sea level).

Background. At high altitude changes in corneal thickness and intraocular pressure (IOP) has been a subject of investigation for decades. The mechanism of action of these changes is still unknown. Extensive research is carried out to know effect of hypoxia on humans at high altitude. Corneal thickness and intraocular pressure are important parameter in ophthalmology with both diagnostic and therapeutic implications. We studied the corneal thickness and intraocular pressure in highlanders and compared the same with lowlanders. Methods. This observational study included two groups, each consisting of 500 individuals residing at high altitude (more than 10,000 ft above sea level). Three measurements of intraocular pressure of both eyes in each group were noted with Goldmann applanation tonometer and mean of the three readings was taken. Central Corneal Thickness (CCT) was measured by ultra sound pachymetry. The parameters of two groups were compared statistically. Results. There was a statistically significant difference between corneal thicknesses of the two groups studied, however no overall statistically significant difference in intraocular pressure of both these groups was found. Conclusion. The highlanders have a thinner cornea as compared to lowlanders. The IOP is significantly higher in the highlander males as compared to lowlander males. However, the mean IOP is comparable between the overall population of the high altitude and that of low altitude.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信