{"title":"评估Determine的敏感性和特异性™ 使用冈比亚医学研究委员会单位生产的0.01M磷酸盐缓冲盐水进行HIV-1/2快速检测,用于诊断HIV。","authors":"Anna Boté-Casamitjana, Tisbeh Faye-Joof, Ousman Bah, Sira Jallow, Alagie Camara, Olimatou Jallow, Nuredin Mohammed, Karen Forrest, Behzad Nadjm","doi":"10.1093/trstmh/trad071","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Human immunodeficiency virus (HIV) rapid diagnostic tests (RDTs) are widely used. However, buffer stockouts commonly lead to utilising non-approved liquids, resulting in errors. Our aim was to evaluate the diagnostic accuracy of an alternative buffer.</p><p><strong>Methods: </strong>Paired Determine HIV-1/2 rapid tests with commercial buffer and locally produced 0.01M phosphate-buffered saline (PBS) were performed on consecutive consenting individuals requiring HIV testing. Serum samples were sent for confirmation through the local gold-standard algorithm (Murex HIV Ag/Ab, Hexagon HIV with/without Geenius HIV 1/2). Test accuracy, κ and exact McNemar's test were also carried out.</p><p><strong>Results: </strong>Of 167 participants, 137 had confirmatory testing. The sensitivity of the Determine HIV-1/2 test using PBS compared with the gold standard was 100% (95% confidence interval [CI] 90.5 to 100) with a specificity of 98% (95% CI 92.9 to 99.8). The κ value was 0.94 compared with the gold standard and 0.92 compared with the Determine HIV-1/2 test using the commercial buffer. McNemar's test showed no evidence of differing sensitivities. Due to operational constraints, the study included 37 of the 49 positive cases as determined by the sample size calculation, resulting in an attained power of 80% instead of the intended 90%.</p><p><strong>Conclusions: </strong>These results suggest that 0.01M PBS is an alternative solution for Determine HIV-1/2 when buffer stockouts occur.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10833640/pdf/","citationCount":"0","resultStr":"{\"title\":\"Evaluating the sensitivity and specificity of Determine™ HIV-1/2 rapid test using a 0.01M phosphate-buffered saline produced at the Medical Research Council Unit The Gambia for the diagnosis of HIV.\",\"authors\":\"Anna Boté-Casamitjana, Tisbeh Faye-Joof, Ousman Bah, Sira Jallow, Alagie Camara, Olimatou Jallow, Nuredin Mohammed, Karen Forrest, Behzad Nadjm\",\"doi\":\"10.1093/trstmh/trad071\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Human immunodeficiency virus (HIV) rapid diagnostic tests (RDTs) are widely used. However, buffer stockouts commonly lead to utilising non-approved liquids, resulting in errors. Our aim was to evaluate the diagnostic accuracy of an alternative buffer.</p><p><strong>Methods: </strong>Paired Determine HIV-1/2 rapid tests with commercial buffer and locally produced 0.01M phosphate-buffered saline (PBS) were performed on consecutive consenting individuals requiring HIV testing. Serum samples were sent for confirmation through the local gold-standard algorithm (Murex HIV Ag/Ab, Hexagon HIV with/without Geenius HIV 1/2). Test accuracy, κ and exact McNemar's test were also carried out.</p><p><strong>Results: </strong>Of 167 participants, 137 had confirmatory testing. The sensitivity of the Determine HIV-1/2 test using PBS compared with the gold standard was 100% (95% confidence interval [CI] 90.5 to 100) with a specificity of 98% (95% CI 92.9 to 99.8). The κ value was 0.94 compared with the gold standard and 0.92 compared with the Determine HIV-1/2 test using the commercial buffer. McNemar's test showed no evidence of differing sensitivities. Due to operational constraints, the study included 37 of the 49 positive cases as determined by the sample size calculation, resulting in an attained power of 80% instead of the intended 90%.</p><p><strong>Conclusions: </strong>These results suggest that 0.01M PBS is an alternative solution for Determine HIV-1/2 when buffer stockouts occur.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10833640/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1093/trstmh/trad071\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/trstmh/trad071","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
摘要
背景:人类免疫缺陷病毒(HIV)快速诊断试验(RDTs)应用广泛。然而,缓冲器缺货通常会导致使用未经批准的液体,从而导致错误。我们的目的是评估替代缓冲液的诊断准确性。方法:用商业缓冲液和本地生产的0.01M磷酸盐缓冲盐水(PBS)对需要HIV检测的连续同意个体进行配对测定HIV-1/2快速检测。通过当地金标准算法(Murex HIV Ag/Ab,Hexagon HIV带/不带Geenius HIV 1/2)发送血清样本进行确认。还进行了检验准确性、κ和精确的McNemar检验。结果:在167名参与者中,137人进行了验证性测试。与金标准相比,使用PBS测定HIV-1/2试验的灵敏度为100%(95%置信区间[CI]90.5至100),特异性为98%(95%可信区间92.9至99.8)。与金标准比较,κ值为0.94,与使用商业缓冲液测定HIV-1/2试验相比为0.92。McNemar的测试没有显示出不同敏感性的证据。由于操作限制,该研究包括了样本量计算确定的49例阳性病例中的37例,结果获得了80%的功率,而不是预期的90%。结论:这些结果表明,当缓冲液缺货时,0.01M PBS是确定HIV-1/2的替代解决方案。
Evaluating the sensitivity and specificity of Determine™ HIV-1/2 rapid test using a 0.01M phosphate-buffered saline produced at the Medical Research Council Unit The Gambia for the diagnosis of HIV.
Background: Human immunodeficiency virus (HIV) rapid diagnostic tests (RDTs) are widely used. However, buffer stockouts commonly lead to utilising non-approved liquids, resulting in errors. Our aim was to evaluate the diagnostic accuracy of an alternative buffer.
Methods: Paired Determine HIV-1/2 rapid tests with commercial buffer and locally produced 0.01M phosphate-buffered saline (PBS) were performed on consecutive consenting individuals requiring HIV testing. Serum samples were sent for confirmation through the local gold-standard algorithm (Murex HIV Ag/Ab, Hexagon HIV with/without Geenius HIV 1/2). Test accuracy, κ and exact McNemar's test were also carried out.
Results: Of 167 participants, 137 had confirmatory testing. The sensitivity of the Determine HIV-1/2 test using PBS compared with the gold standard was 100% (95% confidence interval [CI] 90.5 to 100) with a specificity of 98% (95% CI 92.9 to 99.8). The κ value was 0.94 compared with the gold standard and 0.92 compared with the Determine HIV-1/2 test using the commercial buffer. McNemar's test showed no evidence of differing sensitivities. Due to operational constraints, the study included 37 of the 49 positive cases as determined by the sample size calculation, resulting in an attained power of 80% instead of the intended 90%.
Conclusions: These results suggest that 0.01M PBS is an alternative solution for Determine HIV-1/2 when buffer stockouts occur.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.