指伸肌扩张的支持带韧带:一项解剖学和生物力学研究。

IF 2.3 4区 医学 Q1 ANATOMY & MORPHOLOGY
Clinical Anatomy Pub Date : 2023-09-25 DOI:10.1002/ca.24114
Tomas Borgström, Lars B Dahlin, Jørgen Tranum-Jensen
{"title":"指伸肌扩张的支持带韧带:一项解剖学和生物力学研究。","authors":"Tomas Borgström,&nbsp;Lars B Dahlin,&nbsp;Jørgen Tranum-Jensen","doi":"10.1002/ca.24114","DOIUrl":null,"url":null,"abstract":"<p><p>Our aim was to clarify the anatomy and function of the retinacular ligaments. Forty-eight fingers were dissected and the thickness of the oblique retinacular ligament (ORL) was graded. In four fingers, the motion in the proximal interphalangeal (PIP) and distal interphalangeal (DIP) joints was subjected to an in-depth analysis before and after sectioning of either the lateral bands (LB) or the ORLs. The function of the ORLs in restricting flexion of the DIP joint with full extension of the PIP joint was measured in 10 fingers. An ORL could be identified on both sides in all 48 fingers. The distribution of the insertion on the proximal phalanx was 7/96 (7%) in the distal third, 70/96 (73%) in the middle third and 19/96 (20%) in the proximal third. Among the specimens, 29% were graded as having a strong bundle of fibers, 51% as having well-defined and regular fibers and 20% as having thin and sparse fibers. With the PIP joint extended, there was a statistically significant increase in flexion of the DIP joint after the ORL was cut. After the LB was sectioned, the ORL was able to extend the DIP joint with an extension lag of 10-22°. Cutting the ORL did not affect the ability to extend that joint. We conclude that the retinacular ligaments are consistent. Their major role is not connected with finger movement, but to provide stabilizing links between the PIP and DIP joints. They are active in not only specific, uncommon finger positions but also in ordinary use of the fingers.</p>","PeriodicalId":50687,"journal":{"name":"Clinical Anatomy","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2023-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The retinacular ligaments of the digital extensor expansion revisited: An anatomical and biomechanical study.\",\"authors\":\"Tomas Borgström,&nbsp;Lars B Dahlin,&nbsp;Jørgen Tranum-Jensen\",\"doi\":\"10.1002/ca.24114\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Our aim was to clarify the anatomy and function of the retinacular ligaments. Forty-eight fingers were dissected and the thickness of the oblique retinacular ligament (ORL) was graded. In four fingers, the motion in the proximal interphalangeal (PIP) and distal interphalangeal (DIP) joints was subjected to an in-depth analysis before and after sectioning of either the lateral bands (LB) or the ORLs. The function of the ORLs in restricting flexion of the DIP joint with full extension of the PIP joint was measured in 10 fingers. An ORL could be identified on both sides in all 48 fingers. The distribution of the insertion on the proximal phalanx was 7/96 (7%) in the distal third, 70/96 (73%) in the middle third and 19/96 (20%) in the proximal third. Among the specimens, 29% were graded as having a strong bundle of fibers, 51% as having well-defined and regular fibers and 20% as having thin and sparse fibers. With the PIP joint extended, there was a statistically significant increase in flexion of the DIP joint after the ORL was cut. After the LB was sectioned, the ORL was able to extend the DIP joint with an extension lag of 10-22°. Cutting the ORL did not affect the ability to extend that joint. We conclude that the retinacular ligaments are consistent. Their major role is not connected with finger movement, but to provide stabilizing links between the PIP and DIP joints. They are active in not only specific, uncommon finger positions but also in ordinary use of the fingers.</p>\",\"PeriodicalId\":50687,\"journal\":{\"name\":\"Clinical Anatomy\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2023-09-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical Anatomy\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1002/ca.24114\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ANATOMY & MORPHOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Anatomy","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/ca.24114","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ANATOMY & MORPHOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

我们的目的是阐明支持带韧带的解剖结构和功能。解剖48个手指,并对斜支持带韧带(ORL)的厚度进行分级。在四个手指中,在侧带(LB)或ORL切片前后,对近端指间(PIP)和远端指间(DIP)关节的运动进行了深入分析。在10个手指中测量了ORL在限制DIP关节屈曲和PIP关节完全伸展方面的功能。在所有48个手指的两侧都可以识别出ORL。近端指骨上的插入分布在远端三分之一中为7/96(7%),在中间三分之一为70/96(73%),在近端三分之一是19/96(20%)。在这些样本中,29%的样本被评为具有强纤维束,51%的样本具有明确且规则的纤维,20%的样本具有细且稀疏的纤维。随着PIP关节的伸展,切开ORL后DIP关节的屈曲有统计学意义的增加。LB切片后,ORL能够以10-22°的延伸滞后延伸DIP接头。切割ORL不会影响延伸接头的能力。我们得出结论,支持带韧带是一致的。它们的主要作用与手指运动无关,而是在PIP和DIP关节之间提供稳定的连接。它们不仅活跃在特定的、不常见的手指位置,而且活跃在手指的日常使用中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The retinacular ligaments of the digital extensor expansion revisited: An anatomical and biomechanical study.

Our aim was to clarify the anatomy and function of the retinacular ligaments. Forty-eight fingers were dissected and the thickness of the oblique retinacular ligament (ORL) was graded. In four fingers, the motion in the proximal interphalangeal (PIP) and distal interphalangeal (DIP) joints was subjected to an in-depth analysis before and after sectioning of either the lateral bands (LB) or the ORLs. The function of the ORLs in restricting flexion of the DIP joint with full extension of the PIP joint was measured in 10 fingers. An ORL could be identified on both sides in all 48 fingers. The distribution of the insertion on the proximal phalanx was 7/96 (7%) in the distal third, 70/96 (73%) in the middle third and 19/96 (20%) in the proximal third. Among the specimens, 29% were graded as having a strong bundle of fibers, 51% as having well-defined and regular fibers and 20% as having thin and sparse fibers. With the PIP joint extended, there was a statistically significant increase in flexion of the DIP joint after the ORL was cut. After the LB was sectioned, the ORL was able to extend the DIP joint with an extension lag of 10-22°. Cutting the ORL did not affect the ability to extend that joint. We conclude that the retinacular ligaments are consistent. Their major role is not connected with finger movement, but to provide stabilizing links between the PIP and DIP joints. They are active in not only specific, uncommon finger positions but also in ordinary use of the fingers.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Clinical Anatomy
Clinical Anatomy 医学-解剖学与形态学
CiteScore
5.50
自引率
12.50%
发文量
154
审稿时长
3 months
期刊介绍: Clinical Anatomy is the Official Journal of the American Association of Clinical Anatomists and the British Association of Clinical Anatomists. The goal of Clinical Anatomy is to provide a medium for the exchange of current information between anatomists and clinicians. This journal embraces anatomy in all its aspects as applied to medical practice. Furthermore, the journal assists physicians and other health care providers in keeping abreast of new methodologies for patient management and informs educators of new developments in clinical anatomy and teaching techniques. Clinical Anatomy publishes original and review articles of scientific, clinical, and educational interest. Papers covering the application of anatomic principles to the solution of clinical problems and/or the application of clinical observations to expand anatomic knowledge are welcomed.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信