{"title":"单体氧化锆种植体支持单冠或固定义齿的中期临床行为:一项系统综述和荟萃分析。","authors":"Margalida Santmartí-Oliver,&nbsp;Lucía Hernando-Calzado,&nbsp;Jorge Cortés-Bretón Brinkmann,&nbsp;Luis Sánchez-Labrador,&nbsp;Luis Miguel Sáez Alcaide,&nbsp;Cristina Meniz-García","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This systematic review aimed to evaluate the medium-term (3-year) overall survival and success rates, marginal bone loss and different biological parameters displayed with one-piece zirconia implants.</p><p><strong>Materials and methods: </strong>Electronic searches were conducted of the MEDLINE (via PubMed), Scopus (Elsevier), Cochrane Library (Wiley) and Web of Science (Clarivate Analytics) databases and manual searching was also performed for relevant articles published up to 14 November 2022. The review included human studies with a minimum of 10 subjects and/or 20 implants and with a follow-up period of at least 3 years after implant placement.</p><p><strong>Results: </strong>Twelve studies met the inclusion criteria and were included for analysis, giving a total of 1,621 one-piece zirconia implants. Eleven studies were included to perform a meta-analysis of survival rates, and six for success rates and marginal bone loss. The survival and success rates at the 3-year follow-up were 94.4% (95% confidence interval 90.4%-98.4%; P < 0.001) and 91.6% (95% confidence interval 84.2%-98.9%; P < 0.001), respectively, and marginal bone loss was 0.231 mm (95% confidence interval 0.190-0.272; P < 0.001).</p><p><strong>Conclusions: </strong>One-piece zirconia implants appear to be a reliable option for restoring missing teeth, obtaining an implant survival rate of 94.4% and a success rate of 91.6% after a follow-up period of at least 3 years. Moreover, the results showed acceptable rates of marginal bone loss and adequate biological parameters.</p>","PeriodicalId":73463,"journal":{"name":"International journal of oral implantology (Berlin, Germany)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-09-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Medium-term clinical behaviour of one-piece zirconia implants supporting single crowns or fixed dental prostheses: A systematic review and meta-analysis.\",\"authors\":\"Margalida Santmartí-Oliver,&nbsp;Lucía Hernando-Calzado,&nbsp;Jorge Cortés-Bretón Brinkmann,&nbsp;Luis Sánchez-Labrador,&nbsp;Luis Miguel Sáez Alcaide,&nbsp;Cristina Meniz-García\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>This systematic review aimed to evaluate the medium-term (3-year) overall survival and success rates, marginal bone loss and different biological parameters displayed with one-piece zirconia implants.</p><p><strong>Materials and methods: </strong>Electronic searches were conducted of the MEDLINE (via PubMed), Scopus (Elsevier), Cochrane Library (Wiley) and Web of Science (Clarivate Analytics) databases and manual searching was also performed for relevant articles published up to 14 November 2022. The review included human studies with a minimum of 10 subjects and/or 20 implants and with a follow-up period of at least 3 years after implant placement.</p><p><strong>Results: </strong>Twelve studies met the inclusion criteria and were included for analysis, giving a total of 1,621 one-piece zirconia implants. Eleven studies were included to perform a meta-analysis of survival rates, and six for success rates and marginal bone loss. The survival and success rates at the 3-year follow-up were 94.4% (95% confidence interval 90.4%-98.4%; P < 0.001) and 91.6% (95% confidence interval 84.2%-98.9%; P < 0.001), respectively, and marginal bone loss was 0.231 mm (95% confidence interval 0.190-0.272; P < 0.001).</p><p><strong>Conclusions: </strong>One-piece zirconia implants appear to be a reliable option for restoring missing teeth, obtaining an implant survival rate of 94.4% and a success rate of 91.6% after a follow-up period of at least 3 years. Moreover, the results showed acceptable rates of marginal bone loss and adequate biological parameters.</p>\",\"PeriodicalId\":73463,\"journal\":{\"name\":\"International journal of oral implantology (Berlin, Germany)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-09-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International journal of oral implantology (Berlin, Germany)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of oral implantology (Berlin, Germany)","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:本系统综述旨在评估一体式氧化锆植入物的中期(3年)总生存率和成功率、边缘骨丢失和不同生物学参数。材料和方法:对MEDLINE(通过PubMed)、Scopus(爱思唯尔)、Cochrane Library(Wiley)和Web of Science(Clarivate Analytics)数据库进行电子搜索,并对截至2022年11月14日发表的相关文章进行手动搜索。该综述包括至少10名受试者和/或20个植入物的人体研究,植入物放置后的随访期至少为3年。结果:12项研究符合纳入标准并纳入分析,共得到1621个一体式氧化锆植入物。纳入11项研究对生存率进行荟萃分析,6项研究对成功率和边缘骨丢失进行荟萃分析。3年随访的生存率和成功率分别为94.4%(95%置信区间90.4%-98.4%;P<0.001)和91.6%(95%可信区间84.2%-98.9%;P>0.001),边缘骨丢失为0.231mm(95%置信间隔0.190-0.272;P<001),在至少3年的随访期后获得94.4%的植入物存活率和91.6%的成功率。此外,结果显示了可接受的边缘骨丢失率和适当的生物学参数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Medium-term clinical behaviour of one-piece zirconia implants supporting single crowns or fixed dental prostheses: A systematic review and meta-analysis.

Purpose: This systematic review aimed to evaluate the medium-term (3-year) overall survival and success rates, marginal bone loss and different biological parameters displayed with one-piece zirconia implants.

Materials and methods: Electronic searches were conducted of the MEDLINE (via PubMed), Scopus (Elsevier), Cochrane Library (Wiley) and Web of Science (Clarivate Analytics) databases and manual searching was also performed for relevant articles published up to 14 November 2022. The review included human studies with a minimum of 10 subjects and/or 20 implants and with a follow-up period of at least 3 years after implant placement.

Results: Twelve studies met the inclusion criteria and were included for analysis, giving a total of 1,621 one-piece zirconia implants. Eleven studies were included to perform a meta-analysis of survival rates, and six for success rates and marginal bone loss. The survival and success rates at the 3-year follow-up were 94.4% (95% confidence interval 90.4%-98.4%; P < 0.001) and 91.6% (95% confidence interval 84.2%-98.9%; P < 0.001), respectively, and marginal bone loss was 0.231 mm (95% confidence interval 0.190-0.272; P < 0.001).

Conclusions: One-piece zirconia implants appear to be a reliable option for restoring missing teeth, obtaining an implant survival rate of 94.4% and a success rate of 91.6% after a follow-up period of at least 3 years. Moreover, the results showed acceptable rates of marginal bone loss and adequate biological parameters.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信