标记集配置和刚体姿态确定。

IF 1.7 4区 医学 Q4 BIOPHYSICS
John H Challis
{"title":"标记集配置和刚体姿态确定。","authors":"John H Challis","doi":"10.1115/1.4063625","DOIUrl":null,"url":null,"abstract":"<p><p>Image-based motion-analysis systems typically place markers on the bodies of interest. The error in determining segment attitude from these markers is a function the marker position errors, the number of markers, and the spatial distribution of the markers. The spatial distribution includes two factors: the mean square distance of these markers to their geometric center, and the degree of anisotropy in the marker distribution. The purposes of this study were to: (1) present a metric which quantifies the marker spatial distribution (anisotropic to isotropic) and (2) examine the influence of marker distribution on the accuracy of rigid body attitude determination. To test the influence of the marker distribution on body attitude determination 1000 criterion attitudes were determined. These attitudes then had to be estimated for two marker sets for which the marker distribution metric, noise levels, and root-mean-square distance of the markers were systematically varied. Anisotropic marker distributions were shown to negatively affect the accuracy of attitude determination. The influence of anisotropic marker distributions on attitude accuracy could be blunted by increasing the number of markers, increasing the root-mean-square distance of markers from their geometric center, and reducing noise levels. These results have implications for the measurement of the attitudes of body segments. For example, the ability to have a large spatial distribution of markers and a large number of markers to maximize the measurement accuracy of segment attitude is different for a small segment such as the fifth metacarpal compared with the thigh.</p>","PeriodicalId":54871,"journal":{"name":"Journal of Biomechanical Engineering-Transactions of the Asme","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Marker Set Configuration and Rigid Body Attitude Determination.\",\"authors\":\"John H Challis\",\"doi\":\"10.1115/1.4063625\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Image-based motion-analysis systems typically place markers on the bodies of interest. The error in determining segment attitude from these markers is a function the marker position errors, the number of markers, and the spatial distribution of the markers. The spatial distribution includes two factors: the mean square distance of these markers to their geometric center, and the degree of anisotropy in the marker distribution. The purposes of this study were to: (1) present a metric which quantifies the marker spatial distribution (anisotropic to isotropic) and (2) examine the influence of marker distribution on the accuracy of rigid body attitude determination. To test the influence of the marker distribution on body attitude determination 1000 criterion attitudes were determined. These attitudes then had to be estimated for two marker sets for which the marker distribution metric, noise levels, and root-mean-square distance of the markers were systematically varied. Anisotropic marker distributions were shown to negatively affect the accuracy of attitude determination. The influence of anisotropic marker distributions on attitude accuracy could be blunted by increasing the number of markers, increasing the root-mean-square distance of markers from their geometric center, and reducing noise levels. These results have implications for the measurement of the attitudes of body segments. For example, the ability to have a large spatial distribution of markers and a large number of markers to maximize the measurement accuracy of segment attitude is different for a small segment such as the fifth metacarpal compared with the thigh.</p>\",\"PeriodicalId\":54871,\"journal\":{\"name\":\"Journal of Biomechanical Engineering-Transactions of the Asme\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2023-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Biomechanical Engineering-Transactions of the Asme\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1115/1.4063625\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"BIOPHYSICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomechanical Engineering-Transactions of the Asme","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1115/1.4063625","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0

摘要

基于图像的运动分析系统通常在感兴趣的身体上放置标记。根据这些标记确定分段姿态的误差是标记位置误差、标记数量和标记的空间分布的函数。空间分布包括两个因素:这些标记到其几何中心的均方距离,以及标记分布的各向异性程度。本研究的目的是:1)提出一种量化标记空间分布(各向异性到各向同性)的指标,以及2)检查标记分布对刚体姿态确定准确性的影响。为了测试标记分布对身体姿势确定的影响,确定了1000个标准姿势。然后,必须对两个标记集的这些态度进行估计,其中标记的分布度量、噪声水平和均方根距离是系统变化的。各向异性标记分布对姿态确定的准确性产生了负面影响。各向异性标记分布对姿态精度的影响可以通过增加标记的数量、增加标记与几何中心的均方根距离和降低噪声水平来减弱。这些结果对测量身体各部分的态度具有启示意义。例如,与大腿相比,具有大的标记空间分布和大量标记以最大化节段姿态的测量精度的能力对于诸如第五掌骨的小节段是不同的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Marker Set Configuration and Rigid Body Attitude Determination.

Image-based motion-analysis systems typically place markers on the bodies of interest. The error in determining segment attitude from these markers is a function the marker position errors, the number of markers, and the spatial distribution of the markers. The spatial distribution includes two factors: the mean square distance of these markers to their geometric center, and the degree of anisotropy in the marker distribution. The purposes of this study were to: (1) present a metric which quantifies the marker spatial distribution (anisotropic to isotropic) and (2) examine the influence of marker distribution on the accuracy of rigid body attitude determination. To test the influence of the marker distribution on body attitude determination 1000 criterion attitudes were determined. These attitudes then had to be estimated for two marker sets for which the marker distribution metric, noise levels, and root-mean-square distance of the markers were systematically varied. Anisotropic marker distributions were shown to negatively affect the accuracy of attitude determination. The influence of anisotropic marker distributions on attitude accuracy could be blunted by increasing the number of markers, increasing the root-mean-square distance of markers from their geometric center, and reducing noise levels. These results have implications for the measurement of the attitudes of body segments. For example, the ability to have a large spatial distribution of markers and a large number of markers to maximize the measurement accuracy of segment attitude is different for a small segment such as the fifth metacarpal compared with the thigh.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.40
自引率
5.90%
发文量
169
审稿时长
4-8 weeks
期刊介绍: Artificial Organs and Prostheses; Bioinstrumentation and Measurements; Bioheat Transfer; Biomaterials; Biomechanics; Bioprocess Engineering; Cellular Mechanics; Design and Control of Biological Systems; Physiological Systems.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信