3D旋转血管造影术中选择性晶状体剂量减少方案对脑血管造影学期间眼睛晶状体辐射暴露的影响:一项随机对照试验。

IF 4.5 1区 医学 Q1 NEUROIMAGING
Jae-Chan Ryu, Jong-Tae Yoon, Byung Jun Kim, Mi Hyeon Kim, Eun Ji Moon, Pae Sun Suh, Yun Hwa Roh, Hye Hyeon Moon, Boseong Kwon, Deok Hee Lee, Yunsun Song
{"title":"3D旋转血管造影术中选择性晶状体剂量减少方案对脑血管造影学期间眼睛晶状体辐射暴露的影响:一项随机对照试验。","authors":"Jae-Chan Ryu, Jong-Tae Yoon, Byung Jun Kim, Mi Hyeon Kim, Eun Ji Moon, Pae Sun Suh, Yun Hwa Roh, Hye Hyeon Moon, Boseong Kwon, Deok Hee Lee, Yunsun Song","doi":"10.1136/jnis-2023-020730","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>We aimed to investigate the radiation dose to the eye lens (lens dose) during cerebral angiography and to evaluate the effectiveness of the lens dose reduction protocol for 3-dimensional rotational angiography (3D-RA) in reducing overall lens dose exposure.</p><p><strong>Methods: </strong>We conducted a randomized, controlled clinical trial at a tertiary hospital with patients undergoing cerebral angiography. The lens dose reduction protocol in 3D-RA involved raising the table to position the patient's eye lens away from the rotation axis. The lens dose was estimated by measuring the entrance surface air kerma using a photoluminescent glass dosimeter. The lens doses of 3D-RA, overall examination, and image quality were analyzed and compared between the two groups.</p><p><strong>Results: </strong>A total of 20 participants (mean age, 58±9.4 years; including 12 men [60%]) were enrolled and randomly assigned to either the conventional group or the dose reduction group. The median lens dose in 3D-RA was significantly lower in the dose reduction group compared with the conventional group (1.1 mGy vs 4.5 mGy, p<0.001). The total dose was significantly lower in the dose reduction group (median of 7.5 mGy vs 10.2 mGy, p=0.003). In the conventional group, 3D-RA accounted for 46% of the total lens dose, while in the dose reduction group, its proportion decreased to 16%. No significant differences were observed in the image quality between the groups.</p><p><strong>Conclusion: </strong>The lens dose reduction protocol resulted in a significant reduction in the lens dose of the 3D-RA as well as entire cerebral angiography, while maintaining the image quality.</p>","PeriodicalId":16411,"journal":{"name":"Journal of NeuroInterventional Surgery","volume":null,"pages":null},"PeriodicalIF":4.5000,"publicationDate":"2024-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Impact of a selective lens dose reduction protocol in 3D rotational angiography on radiation exposure to the eye lens during cerebral angiography: a randomized controlled trial.\",\"authors\":\"Jae-Chan Ryu, Jong-Tae Yoon, Byung Jun Kim, Mi Hyeon Kim, Eun Ji Moon, Pae Sun Suh, Yun Hwa Roh, Hye Hyeon Moon, Boseong Kwon, Deok Hee Lee, Yunsun Song\",\"doi\":\"10.1136/jnis-2023-020730\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>We aimed to investigate the radiation dose to the eye lens (lens dose) during cerebral angiography and to evaluate the effectiveness of the lens dose reduction protocol for 3-dimensional rotational angiography (3D-RA) in reducing overall lens dose exposure.</p><p><strong>Methods: </strong>We conducted a randomized, controlled clinical trial at a tertiary hospital with patients undergoing cerebral angiography. The lens dose reduction protocol in 3D-RA involved raising the table to position the patient's eye lens away from the rotation axis. The lens dose was estimated by measuring the entrance surface air kerma using a photoluminescent glass dosimeter. The lens doses of 3D-RA, overall examination, and image quality were analyzed and compared between the two groups.</p><p><strong>Results: </strong>A total of 20 participants (mean age, 58±9.4 years; including 12 men [60%]) were enrolled and randomly assigned to either the conventional group or the dose reduction group. The median lens dose in 3D-RA was significantly lower in the dose reduction group compared with the conventional group (1.1 mGy vs 4.5 mGy, p<0.001). The total dose was significantly lower in the dose reduction group (median of 7.5 mGy vs 10.2 mGy, p=0.003). In the conventional group, 3D-RA accounted for 46% of the total lens dose, while in the dose reduction group, its proportion decreased to 16%. No significant differences were observed in the image quality between the groups.</p><p><strong>Conclusion: </strong>The lens dose reduction protocol resulted in a significant reduction in the lens dose of the 3D-RA as well as entire cerebral angiography, while maintaining the image quality.</p>\",\"PeriodicalId\":16411,\"journal\":{\"name\":\"Journal of NeuroInterventional Surgery\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.5000,\"publicationDate\":\"2024-09-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of NeuroInterventional Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1136/jnis-2023-020730\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"NEUROIMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of NeuroInterventional Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1136/jnis-2023-020730","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"NEUROIMAGING","Score":null,"Total":0}
引用次数: 0

摘要

背景:我们旨在研究脑血管造影术期间对晶状体的辐射剂量(晶状体剂量),并评估三维旋转血管造影学(3D-RA)晶状体剂量减少方案在减少晶状体总剂量暴露方面的有效性。方法:我们在一家三级医院对接受脑血管造影的患者进行了随机对照临床试验。3D-RA中的晶状体剂量减少方案包括升高手术台以将患者的晶状体定位为远离旋转轴。透镜剂量是通过使用光致发光玻璃剂量计测量入射表面空气kerma来估计的。分析并比较两组的3D-RA晶状体剂量、整体检查和图像质量。结果:共有20名参与者(平均年龄58±9.4岁;包括12名男性[60%])入选,并被随机分配到常规组或剂量减少组。与常规组相比,剂量减少组的3D-RA中位晶状体剂量显著降低(1.1mGy vs 4.5mGy,P结论:在保持图像质量的同时,晶状体剂量减少方案导致3D-RA和整个脑血管造影的晶状体剂量显著减少。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Impact of a selective lens dose reduction protocol in 3D rotational angiography on radiation exposure to the eye lens during cerebral angiography: a randomized controlled trial.

Background: We aimed to investigate the radiation dose to the eye lens (lens dose) during cerebral angiography and to evaluate the effectiveness of the lens dose reduction protocol for 3-dimensional rotational angiography (3D-RA) in reducing overall lens dose exposure.

Methods: We conducted a randomized, controlled clinical trial at a tertiary hospital with patients undergoing cerebral angiography. The lens dose reduction protocol in 3D-RA involved raising the table to position the patient's eye lens away from the rotation axis. The lens dose was estimated by measuring the entrance surface air kerma using a photoluminescent glass dosimeter. The lens doses of 3D-RA, overall examination, and image quality were analyzed and compared between the two groups.

Results: A total of 20 participants (mean age, 58±9.4 years; including 12 men [60%]) were enrolled and randomly assigned to either the conventional group or the dose reduction group. The median lens dose in 3D-RA was significantly lower in the dose reduction group compared with the conventional group (1.1 mGy vs 4.5 mGy, p<0.001). The total dose was significantly lower in the dose reduction group (median of 7.5 mGy vs 10.2 mGy, p=0.003). In the conventional group, 3D-RA accounted for 46% of the total lens dose, while in the dose reduction group, its proportion decreased to 16%. No significant differences were observed in the image quality between the groups.

Conclusion: The lens dose reduction protocol resulted in a significant reduction in the lens dose of the 3D-RA as well as entire cerebral angiography, while maintaining the image quality.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
9.50
自引率
14.60%
发文量
291
审稿时长
4-8 weeks
期刊介绍: The Journal of NeuroInterventional Surgery (JNIS) is a leading peer review journal for scientific research and literature pertaining to the field of neurointerventional surgery. The journal launch follows growing professional interest in neurointerventional techniques for the treatment of a range of neurological and vascular problems including stroke, aneurysms, brain tumors, and spinal compression.The journal is owned by SNIS and is also the official journal of the Interventional Chapter of the Australian and New Zealand Society of Neuroradiology (ANZSNR), the Canadian Interventional Neuro Group, the Hong Kong Neurological Society (HKNS) and the Neuroradiological Society of Taiwan.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信