D-PLEX100在幼年小型猪腹部手术切口模型中的临床前体内安全性和毒代动力学。

IF 1.2 4区 医学 Q4 PHARMACOLOGY & PHARMACY
International Journal of Toxicology Pub Date : 2024-01-01 Epub Date: 2023-10-03 DOI:10.1177/10915818231205222
Yuval Ramot, Abraham Nyska, Meidan Dvir, Shlomo Nedvetzki, Sefi Rosenfeld, Noam Emanuel
{"title":"D-PLEX100在幼年小型猪腹部手术切口模型中的临床前体内安全性和毒代动力学。","authors":"Yuval Ramot, Abraham Nyska, Meidan Dvir, Shlomo Nedvetzki, Sefi Rosenfeld, Noam Emanuel","doi":"10.1177/10915818231205222","DOIUrl":null,"url":null,"abstract":"<p><p>D-PLEX100 (D-PLEX) is a novel product candidate made of a polymer-lipid-based matrix (PLEX platform) which contains doxycycline that is being released at a constant rate for 30 days. D-PLEX was developed to prevent surgical site infections, which are a major global health challenge. Previous studies have shown its safety in adult humans, adult swine, and adult rabbits. The aim of this study was to assess the toxicity and safety of D-PLEX also in juvenile animals to support future clinical trials in pediatric patients. Yucatan miniature swine were selected as a model, primarily due to their relatively larger mass. D-PLEX or placebo (formulation without doxycycline) was administered locally to abdominal incisions, and the animal's safety parameters were followed for 9 months and compared to sham-control swine. There was no evidence of any systemic safety concern or local toxicity at the incision site in D-PLEX-treated animals. D-PLEX was detected after 1 month and was fully resorbed at the 3-month time point. The surgical incision sites were fully healed at the 6-month time point in all D-PLEX-treated animals. Toxicokinetic (TK) assessments revealed that doxycycline exhibited low C<sub>max</sub> and therefore minimal systemic exposure following a single dose of local administration. This study provides evidence for the safety of D-PLEX and PLEX-based formulation in juvenile miniature swine and supports its further testing in clinical pediatric population. In addition, it can be used as a reference for future preclinical studies aiming to evaluate the safety of other PLEX-based product candidates for the pediatric population.</p>","PeriodicalId":14432,"journal":{"name":"International Journal of Toxicology","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10851645/pdf/","citationCount":"0","resultStr":"{\"title\":\"Preclinical In-Vivo Safety and Toxicokinetics of D-PLEX100 in an Abdominal Surgery Incision Model in Juvenile Miniature Swine.\",\"authors\":\"Yuval Ramot, Abraham Nyska, Meidan Dvir, Shlomo Nedvetzki, Sefi Rosenfeld, Noam Emanuel\",\"doi\":\"10.1177/10915818231205222\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>D-PLEX100 (D-PLEX) is a novel product candidate made of a polymer-lipid-based matrix (PLEX platform) which contains doxycycline that is being released at a constant rate for 30 days. D-PLEX was developed to prevent surgical site infections, which are a major global health challenge. Previous studies have shown its safety in adult humans, adult swine, and adult rabbits. The aim of this study was to assess the toxicity and safety of D-PLEX also in juvenile animals to support future clinical trials in pediatric patients. Yucatan miniature swine were selected as a model, primarily due to their relatively larger mass. D-PLEX or placebo (formulation without doxycycline) was administered locally to abdominal incisions, and the animal's safety parameters were followed for 9 months and compared to sham-control swine. There was no evidence of any systemic safety concern or local toxicity at the incision site in D-PLEX-treated animals. D-PLEX was detected after 1 month and was fully resorbed at the 3-month time point. The surgical incision sites were fully healed at the 6-month time point in all D-PLEX-treated animals. Toxicokinetic (TK) assessments revealed that doxycycline exhibited low C<sub>max</sub> and therefore minimal systemic exposure following a single dose of local administration. This study provides evidence for the safety of D-PLEX and PLEX-based formulation in juvenile miniature swine and supports its further testing in clinical pediatric population. In addition, it can be used as a reference for future preclinical studies aiming to evaluate the safety of other PLEX-based product candidates for the pediatric population.</p>\",\"PeriodicalId\":14432,\"journal\":{\"name\":\"International Journal of Toxicology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10851645/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Toxicology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/10915818231205222\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/10/3 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"PHARMACOLOGY & PHARMACY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Toxicology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/10915818231205222","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/10/3 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

摘要

D-PLEX100(D-PLEX)是一种由聚合物脂质基基质(PLEX平台)制成的新型候选产品,该基质含有以恒定速率释放30天的多西环素。D-PLEX是为了预防手术部位感染而开发的,这是一个重大的全球健康挑战。先前的研究表明,它在成年人、成年猪和成年兔中是安全的。本研究的目的是评估D-PLEX在幼年动物中的毒性和安全性,以支持未来在儿科患者中的临床试验。尤卡坦小型猪被选为模型,主要是因为它们的质量相对较大。D-PLEX或安慰剂(不含多西环素的配方)被局部用于腹部切口,动物的安全参数被跟踪9个月,并与假对照猪进行比较。在D-PLEX治疗的动物中,没有证据表明切口部位存在任何系统安全问题或局部毒性。D-PLEX在1个月后被检测到,并且在3个月的时间点被完全吸收。在所有D-PLEX治疗的动物中,手术切口部位在6个月的时间点完全愈合。毒代动力学(TK)评估显示,单剂量局部给药后,多西环素的Cmax较低,因此全身暴露量最小。本研究为D-PLEX和基于PLEX的制剂在幼年小型猪中的安全性提供了证据,并支持其在临床儿科人群中的进一步测试。此外,它可以作为未来临床前研究的参考,旨在评估其他基于PLEX的候选产品对儿科人群的安全性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Preclinical In-Vivo Safety and Toxicokinetics of D-PLEX100 in an Abdominal Surgery Incision Model in Juvenile Miniature Swine.

D-PLEX100 (D-PLEX) is a novel product candidate made of a polymer-lipid-based matrix (PLEX platform) which contains doxycycline that is being released at a constant rate for 30 days. D-PLEX was developed to prevent surgical site infections, which are a major global health challenge. Previous studies have shown its safety in adult humans, adult swine, and adult rabbits. The aim of this study was to assess the toxicity and safety of D-PLEX also in juvenile animals to support future clinical trials in pediatric patients. Yucatan miniature swine were selected as a model, primarily due to their relatively larger mass. D-PLEX or placebo (formulation without doxycycline) was administered locally to abdominal incisions, and the animal's safety parameters were followed for 9 months and compared to sham-control swine. There was no evidence of any systemic safety concern or local toxicity at the incision site in D-PLEX-treated animals. D-PLEX was detected after 1 month and was fully resorbed at the 3-month time point. The surgical incision sites were fully healed at the 6-month time point in all D-PLEX-treated animals. Toxicokinetic (TK) assessments revealed that doxycycline exhibited low Cmax and therefore minimal systemic exposure following a single dose of local administration. This study provides evidence for the safety of D-PLEX and PLEX-based formulation in juvenile miniature swine and supports its further testing in clinical pediatric population. In addition, it can be used as a reference for future preclinical studies aiming to evaluate the safety of other PLEX-based product candidates for the pediatric population.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.40
自引率
4.50%
发文量
53
审稿时长
4.5 months
期刊介绍: The International Journal of Toxicology publishes timely, peer-reviewed papers on current topics important to toxicologists. Six bi-monthly issues cover a wide range of topics, including contemporary issues in toxicology, safety assessments, novel approaches to toxicological testing, mechanisms of toxicity, biomarkers, and risk assessment. The Journal also publishes invited reviews on contemporary topics, and features articles based on symposia. In addition, supplemental issues are routinely published on various special topics, including three supplements devoted to contributions from the Cosmetic Review Expert Panel.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信