使用立体光刻3D打印制造的具有不同根部几何形状的三种可移除模具设计的位置真实性。

IF 4.3 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Journal of Prosthetic Dentistry Pub Date : 2025-01-01 Epub Date: 2023-10-04 DOI:10.1016/j.prosdent.2023.08.036
Francisco X Azpiazu-Flores, William M Johnston, Severino J Mata-Mata, Burak Yilmaz
{"title":"使用立体光刻3D打印制造的具有不同根部几何形状的三种可移除模具设计的位置真实性。","authors":"Francisco X Azpiazu-Flores, William M Johnston, Severino J Mata-Mata, Burak Yilmaz","doi":"10.1016/j.prosdent.2023.08.036","DOIUrl":null,"url":null,"abstract":"<p><strong>Statement of problem: </strong>Three-dimensional (3D) printed casts are a suitable alternative to dental stone casts. Contemporary dental design computer programs permit designing definitive casts with removable dies with different root geometries and retention mechanisms. Studies on the positional trueness of 3D printed removable dies with different root geometries are lacking.</p><p><strong>Purpose: </strong>The purpose of this in vitro study was to investigate the 3D displacements of three 3D printed removable die designs with different root geometries.</p><p><strong>Material and methods: </strong>The digital file of a dental stone alveolar cast with root-form removable dies (MOD UJ IV Fixed Prosthetics; Ivoclar AG) was used as a reference to create 3 removable die and alveolar cast designs (Root Form, RF; Conical, CON; Cylindric, CYL) with different root geometries in 2 dental design computer programs (DentalCAD 3.1 Rijeka; exocad; GmbH; InLab CAD 22.0; Dentsply Sirona). 3 equidistant Ø1-mm spheres (C, Cervical; M, Middle; O, Occlusal) were designed on the buccal surface of the coronal portion of the removable die to evaluate their displacement. A total of 45 alveolar casts with 45 removable dies were fabricated using a stereolithographic 3D printer (Form 3; Formlabs); each die group consisted of 15 specimens. After fabrication and postprocessing, the specimens were scanned, and their digital files were analyzed in a metrology-grade computer program to evaluate the displacement of the removable dies with respect to the position of the die in the master reference file. Subsequently, the data were analyzed using a 3-way analysis of variance (ANOVA) followed by step-down Bonferroni-corrected pairwise comparisons (α=.05).</p><p><strong>Results: </strong>Two statistically significant 2-way interactions were detected between the independent variables, die design and direction (P<.001), and location and direction (P<.001). The post hoc analysis identified significant differences between the displacement values of RF and CYL (P<.001) and RF and the CON (P<.001) designs on the Y axis. The measured displacements were statistically different between the C and O locations on the Y axis (P=.001) and the M and O locations on the Z axis (P=.006).</p><p><strong>Conclusions: </strong>The root geometry of a 3D printed removable die and alveolar cast can affect seating, and variable degrees of tipping of the removable die can be seen. The seating and congruence of the removable die with the interocclusal space and relationships observed intraorally should be confirmed before adjusting indirect restorations.</p>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":" ","pages":"178-183"},"PeriodicalIF":4.3000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Positional trueness of three removable die designs with different root geometries manufactured using stereolithographic 3D printing.\",\"authors\":\"Francisco X Azpiazu-Flores, William M Johnston, Severino J Mata-Mata, Burak Yilmaz\",\"doi\":\"10.1016/j.prosdent.2023.08.036\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Statement of problem: </strong>Three-dimensional (3D) printed casts are a suitable alternative to dental stone casts. Contemporary dental design computer programs permit designing definitive casts with removable dies with different root geometries and retention mechanisms. Studies on the positional trueness of 3D printed removable dies with different root geometries are lacking.</p><p><strong>Purpose: </strong>The purpose of this in vitro study was to investigate the 3D displacements of three 3D printed removable die designs with different root geometries.</p><p><strong>Material and methods: </strong>The digital file of a dental stone alveolar cast with root-form removable dies (MOD UJ IV Fixed Prosthetics; Ivoclar AG) was used as a reference to create 3 removable die and alveolar cast designs (Root Form, RF; Conical, CON; Cylindric, CYL) with different root geometries in 2 dental design computer programs (DentalCAD 3.1 Rijeka; exocad; GmbH; InLab CAD 22.0; Dentsply Sirona). 3 equidistant Ø1-mm spheres (C, Cervical; M, Middle; O, Occlusal) were designed on the buccal surface of the coronal portion of the removable die to evaluate their displacement. A total of 45 alveolar casts with 45 removable dies were fabricated using a stereolithographic 3D printer (Form 3; Formlabs); each die group consisted of 15 specimens. After fabrication and postprocessing, the specimens were scanned, and their digital files were analyzed in a metrology-grade computer program to evaluate the displacement of the removable dies with respect to the position of the die in the master reference file. Subsequently, the data were analyzed using a 3-way analysis of variance (ANOVA) followed by step-down Bonferroni-corrected pairwise comparisons (α=.05).</p><p><strong>Results: </strong>Two statistically significant 2-way interactions were detected between the independent variables, die design and direction (P<.001), and location and direction (P<.001). The post hoc analysis identified significant differences between the displacement values of RF and CYL (P<.001) and RF and the CON (P<.001) designs on the Y axis. The measured displacements were statistically different between the C and O locations on the Y axis (P=.001) and the M and O locations on the Z axis (P=.006).</p><p><strong>Conclusions: </strong>The root geometry of a 3D printed removable die and alveolar cast can affect seating, and variable degrees of tipping of the removable die can be seen. The seating and congruence of the removable die with the interocclusal space and relationships observed intraorally should be confirmed before adjusting indirect restorations.</p>\",\"PeriodicalId\":16866,\"journal\":{\"name\":\"Journal of Prosthetic Dentistry\",\"volume\":\" \",\"pages\":\"178-183\"},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Prosthetic Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.prosdent.2023.08.036\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/10/4 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.prosdent.2023.08.036","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/10/4 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

问题陈述:三维(3D)打印铸造是牙石铸造的合适替代品。现代牙科设计计算机程序允许设计具有不同根部几何形状和固位机制的可拆卸模具的最终铸件。缺乏对具有不同根部几何形状的3D打印可拆卸模具的位置真实性的研究。目的:本体外研究的目的是研究三种具有不同根部几何形状的3D打印可拆卸模具设计的3D位移。材料和方法:使用具有根部形状可移除模具的牙石牙槽铸件的数字文件(MOD UJ IV Fixed Prosthetics;Ivoclar AG)作为参考,在2个牙科设计计算机程序中创建了3个具有不同根部几何形状的可移除模具和牙槽铸件设计(根部形状,RF;锥形,CON;圆柱,CYL)(DentalCAD 3.1 Rijeka;exocad;GmbH;InLab CAD 22.0;Dentsply Sirona)。在可移除模具的冠状部分的颊面上设计了3个等距的dst 1-mm球体(C,颈;M,中;O,咬合),以评估其位移。使用立体平版印刷3D打印机(Form 3;Formlabs)制造总共45个具有45个可移除模具的肺泡铸件;每个模具组由15个样本组成。制造和后处理后,对试样进行扫描,并在计量级计算机程序中分析其数字文件,以评估可拆卸模具相对于主参考文件中模具位置的位移。随后,使用三元方差分析(ANOVA)对数据进行分析,然后进行降压Bonferroni校正的成对比较(α=0.05)。结果:自变量之间检测到两个具有统计学意义的双向相互作用,模具设计和方向(P结论:3D打印的可移除模具和牙槽铸型的根部几何形状会影响底座,可以看到可移除模具的不同倾斜度。在调整间接修复体之前,应确认可移除模具与咬合间间隙的底座和一致性,以及在口内观察到的关系。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Positional trueness of three removable die designs with different root geometries manufactured using stereolithographic 3D printing.

Statement of problem: Three-dimensional (3D) printed casts are a suitable alternative to dental stone casts. Contemporary dental design computer programs permit designing definitive casts with removable dies with different root geometries and retention mechanisms. Studies on the positional trueness of 3D printed removable dies with different root geometries are lacking.

Purpose: The purpose of this in vitro study was to investigate the 3D displacements of three 3D printed removable die designs with different root geometries.

Material and methods: The digital file of a dental stone alveolar cast with root-form removable dies (MOD UJ IV Fixed Prosthetics; Ivoclar AG) was used as a reference to create 3 removable die and alveolar cast designs (Root Form, RF; Conical, CON; Cylindric, CYL) with different root geometries in 2 dental design computer programs (DentalCAD 3.1 Rijeka; exocad; GmbH; InLab CAD 22.0; Dentsply Sirona). 3 equidistant Ø1-mm spheres (C, Cervical; M, Middle; O, Occlusal) were designed on the buccal surface of the coronal portion of the removable die to evaluate their displacement. A total of 45 alveolar casts with 45 removable dies were fabricated using a stereolithographic 3D printer (Form 3; Formlabs); each die group consisted of 15 specimens. After fabrication and postprocessing, the specimens were scanned, and their digital files were analyzed in a metrology-grade computer program to evaluate the displacement of the removable dies with respect to the position of the die in the master reference file. Subsequently, the data were analyzed using a 3-way analysis of variance (ANOVA) followed by step-down Bonferroni-corrected pairwise comparisons (α=.05).

Results: Two statistically significant 2-way interactions were detected between the independent variables, die design and direction (P<.001), and location and direction (P<.001). The post hoc analysis identified significant differences between the displacement values of RF and CYL (P<.001) and RF and the CON (P<.001) designs on the Y axis. The measured displacements were statistically different between the C and O locations on the Y axis (P=.001) and the M and O locations on the Z axis (P=.006).

Conclusions: The root geometry of a 3D printed removable die and alveolar cast can affect seating, and variable degrees of tipping of the removable die can be seen. The seating and congruence of the removable die with the interocclusal space and relationships observed intraorally should be confirmed before adjusting indirect restorations.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Prosthetic Dentistry
Journal of Prosthetic Dentistry 医学-牙科与口腔外科
CiteScore
7.00
自引率
13.00%
发文量
599
审稿时长
69 days
期刊介绍: The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信